7
Installation
NOTE:
(**) Measure burner operating pressure at target top hob manifold test point with target
top burner (Inner and outer ring) operating at full setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
TOWN GAS Only - Burner operating pressure is to be adjusted using adjustable gas
regulator supplied. Town Gas Option is only available with specific ex-factory built
Town Gas models, which can also be converted to any other gas. Standard models can
only be converted between Nat. Gas, LP Gas and Butane, but not Town Gas.
Refer to ‘Gas Conversion and Specifications' section of this manual for further details.
Regulator connections are 3/4" BSP female.
Connection to appliance is 3/4" BSP male.
(Refer to 'Specifications' section for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line.
4. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
appliance is level and at correct height.
5. Connect gas supply to appliance. A suitable joining compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
6. Check all gas connections for leakages using soapy water or other gas detecting equipment.
7. Check gas operating pressure is as shown in 'Specifications'
section.
NOTE: Measure burner operating pressure at target top
hob manifold test point with target top burner (Inner
and outer ring) operating at full setting.
8. Turn ‘Off’ mains gas supply and bleed gas out of appliance
gas lines.
9. Turn ‘On’ gas supply and appliance.
10. Verify operating pressure remains correct.
Commissioning
Before leaving the new installation;
Check the following functions in accordance with operating instructions specified in 'Operation'
section of this manual.
Light the Target Top Pilot Burners.
Light the Target Top Main Burners.
Light the Oven Pilot and Main Burners.
Check the Oven Main Burner Thermostat operation.
Check the Low Fire Burner operation for Target Top and Oven.
Check the High Fire Burner operation for Target Top and Oven.
Ensure operator has been instructed in areas of correct lighting, operation, and shutdown procedure
for appliance.
This manual must be kept by the owner for future reference, and a record of
Date of Purchase,
Date of
Installation
and
Serial Number of Appliance
recorded and kept with this manual. (These details can
be found on Rating Plate attached to lower right hand side of sill panel. Refer to 'Gas
Connection' section).
NOTE: If for some reason it is not possible to get appliance to operate correctly, shut ‘Off’ gas
supply and contact supplier of this appliance.
Fig 2
Low Fire
Adjustment
Screw
Manifold
Pressure Test
Point
DONOT USE ANAKED FLAME TO CHECK FOR GAS LEAKAGES.
Warning