Model: BMRE06
Thank you for purchasing this
BodiSure Cushion Massager.
Read this instruction manual thoroughly
before using the product. Please ensure
you observe the safety instructions to
avoid accidents, injury and damage.
Please keep this instruction manual in
a safe place where it is readily available.
The illustrations in this manual may
differ slightly from the product itself
Contents
Important Safety Information . . . . . . . . . . . . . . 3
Features . . . . . . . . . . . . . . . . . . . . . . 6
Product Contents . . . . . . . . . . . . . . . . . . . 6
Massager Components . . . . . . . . . . . . . . . . 6
Before Using the Massager . . . . . . . . . . . . . . . 7
Using the Massager . . . . . . . . . . . . . . . . . . 8
Maintenance. . . . . . . . . . . . . . . . . . . . . 8
Troubleshooting . . . . . . . . . . . . . . . . . . . 9
Warranty . . . . . . . . . . . . . . . . . . . . . .10
Technical Data . . . . . . . . . . . . . . . . . . . .11
Disposal . . . . . . . . . . . . . . . . . . . . . .12
2. BodiSure Cushion Massager with heat Instruction Manual & Warranty Information
DJL-RE06_Instruction-Manual.indd 2 16/08/2017 4:52 PM

Important Safety Information
Read this section thoroughly before using the product.
Please ensure you observe the safety instructions to avoid
accidents, injury and damage.
Please keep this instruction manual in a safe place where
it is readily available.
Intended purpose
• The BodiSure Cushion Massager is for massaging multiple areas of the body.
DO NOT use for purposes other than massage. It is not a therapeutic device.
• It is designed for private use. It is not suitable for commercial use, e.g. in medical
practices, hospitals or in the medical eld.
• The product must not be used outdoors.
• The product may only be used with the supplied power adaptor.
Safety Warnings
• This product is not intended for use by persons (including children) with limited
physical, sensory or mental abilities or lacking experience and/or knowledge,
unless they are supervised by a person responsible for their safety or have
received and understand instructions/hazards for use of the product from this
person in advance.
• Keep children away from packaging material. Ensure that the packaging bag is
not put over the head as this is a suffocation hazard or choking hazard if
swallowed.
• DO NOT leave the product unsupervised while it is connected to the power
supply. Ensure that children cannot play with the product.
• In the following cases, DO NOT use the product or consult your healthcare
professional prior to use:
- with any electronic medical devices e.g. pacemakers, ECGs, articial
respirators etc. as the massager may cause these devices to malfunction;
- if you have medical implants e.g. hip replacement etc.;
- if you are pregnant;
- if you have a chronic or major disease e.g. heart disease, cancer, stroke etc.;
- if you suffer from skin disorders, circulatory problems (e.g. thrombosis), internal
or external injuries, nerve irritation, joint disorders (e.g. arthritis);
- if you have had recent surgery or have broken skin;
- if you are unwell;
- if you feel pain or discomfort during the massage.
BodiSure Cushion Massager with heat Instruction Manual & Warranty Information 3.
DJL-RE06_Instruction-Manual.indd 3 16/08/2017 4:52 PM

• The appliance has a heated surface. Persons sensitive to heat must
be careful when using the appliance.
• DO NOT use while wearing hard objects such as jewellery.
• DO NOT massage the skin directly.
• DO NOT use while using any other electrical devices.
• DO NOT use on the throat, head, stomach, chest, elbows, knees,
or other bones.
• DO NOT use the massager immediately after eating, allow 1 hour before using.
• DO NOT fall asleep during use.
• DO NOT use the product for more than 15 minutes at a time. The massager
will automatically stop after 15 minutes. Allow the massager to cool off completely
before using it again. Excessive use is not recommended.
Electrical Hazards
• DO NOT use the massager:
- if it or the cover is damaged;
- if it is extremely dirty;
- if the power plug, power cord or power buttons are damaged;
- if a malfunction occurs during operation e.g. overheating;
Contact our service centre if any of the issues above occur.
• Disconnect the power plug from the electrical outlet:
- if you are not using the product;
- after each use;
- before cleaning - note the cover is not washable.
Refer maintenance instructions.
- before putting the product away;
- if a malfunction occurs during operation e.g. overheating;
- during a power outage;
- in a thunder storm.
• Always pull from the power plug, not from the cord.
• Only touch the product with dry hands! The product must not be exposed to
dripping or spray water.
• DO NOT immerse in water or other liquids. Electrical shock hazard! Therefore,
DO NOT use the product in the vicinity of moisture sources, e.g. in a bathroom.
• If the product comes into contact with water, disconnect the AC adaptor from the
electrical outlet. Before re-operating, get it checked by our service centre.
4. BodiSure Cushion Massager with heat Instruction Manual & Warranty Information
Important Safety Information - continued
DJL-RE06_Instruction-Manual.indd 4 16/08/2017 4:52 PM

• DO NOT use the massager near hot objects such as stoves, or inside
electric blankets etc.
• The massager is only to be used with the AC adaptor provided with the unit
by the manufacturer.
• Unwind the power cord completely prior to use (DO NOT forcibly bend, twist
or pull). In doing so, ensure that the power cord is not trapped, squeezed,
placed under heavy items or damaged by sharp edges or hot items.
• Securely connect the product to a properly installed electrical outlet with voltage
corresponding to the technical data.
• When using an adaptor plug or extension cord, these must comply with the valid
safety regulations. The specied maximum voltage must not be exceeded.
• Ensure the power cord does not become a trip hazard.
• Ensure that the socket is well-accessible, so that you can remove the power
plug quickly, if necessary.
• DO NOT carry or pull the product by the electric cords.
• DO NOT drop or forcibly press the massager, or place foreign objects
between the massage heads, or stop the movement of the massage heads.
• DO NOT step, stand or sit on top of the product.
• DO NOT place any items on the product, such as magazines, towels,
blankets or similar.
• DO NOT use or store in the following locations:
- Direct sunlight
- High temperature or humidity
- Waterlogged locations
- Dusty location
- Near a naked ame
- Locations easily subject to vibrations or shock
- In strong magnetic elds
• DO NOT carry out any modications to the product, AC adaptor or
its power cord.
• Never attempt to open the product or penetrate it with metal objects.
• Only allow repairs to be carried out by our service centre as per the
warranty conditions.
BodiSure Cushion Massager with heat Instruction Manual & Warranty Information 5.
Important Safety Information - continued
DJL-RE06_Instruction-Manual.indd 5 16/08/2017 4:52 PM

Features
• Shiatsu style massage
• Soft cushion design
• Relaxing massage for multiple body areas
• 4 high quality rotating heads in two directions (clockwise & anti-clockwise)
• Heating option
• Easily positioned using adjustable rear strap
• 15-minute auto-off
Product Contents
A. Cushion Massager
B. AC Adaptor with
2.5m Power Cord
C. Instruction Manual &
Warranty Information
Massager Components
Massager
D. Cover (not removable)
E. Power connector
F. ON/OFF button and
massage direction change
G. ON/OFF button for
heating option
H. Massage heads
(built-in-heating function)
I. Adjustable rear strap
B
C
A
D
H
F
G
E
I
6. BodiSure Cushion Massager with heat Instruction Manual & Warranty Information
DJL-RE06_Instruction-Manual.indd 6 16/08/2017 4:52 PM

AC Adaptor
J. Jack
K. Plug
L. Power cord
Unpacking the Massager
• Remove the product and accessories from the box and keep the
enclosed documents.
• Carefully remove all packaging materials and completely unwind the power
cord on the AC adaptor
• Keep children away from packaging material. Ensure that
the packaging bag is not put over the head as this is a
suffocation hazard or choking hazard if swallowed.
Before Using the Massager
• Check the cover is not torn. If torn DO NOT use.
• Before using the product for the rst time, check whether the voltage specication
on the rating plate corresponds to that of your household.
• Check the switch is operating correctly.
• Make sure the cover is attached during use.
If any abnormalities detected please contact our service centre:
In Australia - 1800 807 464
In New Zealand - 0800 523 583
K
J
L
BodiSure Cushion Massager with heat Instruction Manual & Warranty Information 7.
Massager Components - continued
DJL-RE06_Instruction-Manual.indd 7 16/08/2017 4:52 PM

Using the Massager
1. Ensure massager and heat function are switched OFF.
2. Insert the AC adaptor jack into the power connector.
3. Plug the AC adaptor into an electrical outlet.
4. Position the massager on body area to be massaged.
5. Press the button once to begin massage.
6. To change direction of the massage heads, press the button
once again.
7. If desired, press the button to turn ON the heat function
a. WARNING: Through the heating function, the surface of the cushion
becomes hot in the area of the rotating massage heads. People who are
sensitive to heat should use caution with this function.
8. DO NOT use the product for more than 15 minutes at a time. The massager
will automatically stop after 15 minutes. If you wish to switch off before this time,
press the button until the massager turns off. Allow the massager to cool off
completely before using it again. Excessive use is not recommended.
9. Once nished, ensure the massager and heat function are switched off.
Unplug the AC adaptor from the electrical outlet and then the power
connector (DO NOT pull the power cord).
10. Once the massager has cooled down, store in a safe cool dry place.
Maintenance
Cleaning the Cover
• DO NOT remove the cover from the massager. The massager and cover are
not washable.
• Ensure the massager is switched off and is not connected to any power supply.
• DO NOT immerse in water or other liquids. Electrical shock hazard!
• If required, spot clean the cover with a soft dry cloth.
• If this does not remove the dirt, use a damp soft cloth that has been immersed
in neutral detergent diluted with warm water before wiping. DO NOT use harsh
chemicals or metal items as this may cause damage to the cover.
• Ensure massager is dry before using.
Storage
• Wipe away any dirt and dust from the massager and AC adaptor with a soft
dry cloth.
• Wind up power cords so that tripping hazard is avoided.
• Store in a safe cool dry place away from children.
8. BodiSure Cushion Massager with heat Instruction Manual & Warranty Information
DJL-RE06_Instruction-Manual.indd 8 16/08/2017 4:52 PM

Troubleshooting
Problem Possible Cause Solution
Does not operate. AC adaptor is unplugged. Plug AC adaptor into electrical
outlet.
Connection between AC
adaptor jack and power
connector is loose.
Check connection and ensure
rm connection.
ON button has not been
pressed.
Press ON button once or twice
to start desired direction of
massage.
Massager stops
suddenly.
The massager has stopped
due to auto-off timer after
15 minutes.
This is a normal function.
Allow the massager to cool off
completely before using it again.
The massager has
overheated and safety
temperature function has
been activated.
When temperature exceeds the
safe temperature, the massager
heads will automatically stop
working. Please unplug the unit
from the electrical outlet and let
it cool down. If it still does not
work after this contact the
service centre.
Strength is too
strong.
The massager is at the
wrong angle or it is too
close.
Adjust the massager to a
comfortable position or sit further
away from massager.
The massager is
making noise.
The massager emits a
certain amount of noise
when working.
This is normal. If it is a very loud/
abnormal noise, stop using and
contact the service centre.
The massage heads
do not heat up.
Heat function button has
not been pressed..
Press heat button to switch heat
function ON.
The massager heads
are too hot or there is
a strange smell.
The massager has
overheated.
Turn OFF immediately and allow
to cool down. If still too hot or
strange smell contact the service
centre.
BodiSure Cushion Massager with heat Instruction Manual & Warranty Information 9.
If the problem is not solved by the troubleshooting guide or you have any queries,
please contact our service centre:
In Australia - 1800 807 464
In New Zealand - 0800 523 583
DO NOT attempt to open or repair the product yourself.
DJL-RE06_Instruction-Manual.indd 9 16/08/2017 4:52 PM

Warranty
PRODUCT WARRANTY
Please register your warranty information at:
AUS – www.jadavey.com.au
NZ – www.jadavey.co.nz
This BodiSure device is warranted to be free of manufacturing defects for 1 year from the date of
purchase*. This warranty is void if the product is modied or altered is subject to misuse or abuse,
damaged in transit or lack of responsible care, is dropped, if damage occurs by reason of failure to
follow the written instruction booklet enclosed, or if product repairs are carried out without authority
from J.A.Davey Pty Ltd.
We will repair, or at our option replace free of charge, any parts necessary to correct material
or workmanship, or replace the entire unit and return to you during the period of the warranty.
Otherwise, we will quote for any repair which will be carried out on acceptance of our quotation.
The benets conferred by this warranty are in addition to all other rights and remedies in respect of
the product, which the consumer has under the trade practices act and other state or territory laws
in Australia and New Zealand.
Our goods come with guarantees that cannot be excluded under Australian and New Zealand
Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation
for any other reasonably foreseeable loss or damage. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount
to a major failure.
* Please note the AC adaptor and cover are warranted to be free from defects in materials and
workmanship appearing within one year from the date of purchase when the device is used in
accordance with the instructions provided with the device and are not warranted for wear and tear.
BEFORE YOU SEND IN YOUR UNIT FOR SERVICE
Before sending in your unit for service, please take a few minutes to do the following:
• In your instruction manual, read the troubleshooting section and the section describing common
errors, their cause and remedies. Product instruction manuals can be downloaded online.
• Contact BodiSure customer service. Our staff are trained to assist you with most issues you
may have experienced, without the need to send your product in for service.
PLEASE CALL OUR TOLL FREE NUMBER:
IN AUSTRALIA: Free call: 1800 807 464 IN NEW ZEALAND: Free call: 0800 523 583
SENDING IN YOUR UNIT FOR SERVICE
1. Should repair be needed within the warranty period, enclose the tear off section of this warranty
card and your proof of purchase receipt. Please ensure all relevant details are completed and
before sending your unit in for service. Please ensure your contact details are still current and
include a brief description of the problem you are experiencing together with your purchase
receipt.
2. Include the unit with all product components in your package. This is extremely important,
so our repair technicians can make the correct diagnosis with any problems.
3. Please return the unit, warranty card or repair form at your cost to:
IN AUSTRALIA
J.A.Davey Pty Ltd - BodiSure Repairs
PO Box 84
Port Melbourne
Victoria, Australia 3207
IN NEW ZEALAND
BV Medical - BodiSure Repairs
Unit 7, 110 Mays Road
Onehunga
Auckland, New Zealand 1061
10. BodiSure Cushion Massager with heat Instruction Manual & Warranty Information
DJL-RE06_Instruction-Manual.indd 10 16/08/2017 4:52 PM

Technical Data
Product Name BodiSure Cushion Massager
Model Number BMRE06
Rating Input: 100-240VAC, 50/60Hz 0.8A
Output: 12.0V, 2.0A
Power consumption: 24W
RPM 18 RPM
Operating temperature/humidity Temperature: -10 ˚C to 45 ˚C
Humidity: 10% to 90% RH (non-condensing)
Storage temperature/humidity Temperature: -25 ˚C to 65 ˚C
Humidity: 10% to 90% RH (non-condensing)
Dimensions 39 x 25 x 13cm (out of packaging)
Weight 1.29kgs (without AC adaptor)
Outer Cover Materials PU Leather & Polyester
Max. Heater Temperature 47.1˚C after 15 minutes
(Ambient temperature: 25˚C)
Contents Cushion Massager, AC Adaptor with 2.5m
Power Cord & Instruction Manual
BodiSure Cushion Massager with heat Instruction Manual & Warranty Information 11.
PLEASE RETAIN THIS WARRANTY CARD.
RETURN THIS PORTION ONLY WHEN YOU RETURN YOUR PRODUCT FOR REPAIR
UNDER WARRANTY.
NAME:
ADDRESS:
POSTCODE: DAYTIME TELEPHONE:
EMAIL:
MODEL: DATE OF PURCHASE: / /
PLEASE ATTACH PROOF OF PURCHASE
RETAILER’S NAME:
RETAILER’S ADDRESS:
POSTCODE:
BRIEF DESCRIPTION OF PROBLEM YOU ARE EXPERIENCING:
WARRANTY IS VOID UNLESS THE ABOVE INFORMATION IS COMPLETED AND CORRECT.
DJL-RE06_Instruction-Manual.indd 11 16/08/2017 4:52 PM

Disposal
At the end of its life, please treat this product as electronic waste and
dispose of responsibly according to current local regulations.
12. BodiSure Cushion Massager with heat Instruction Manual & Warranty Information
IN AUSTRALIA:
J.A.DAVEY PTY LTD
Telephone: 1800 807 464
Website: www.jadavey.com.au
IN NEW ZEALAND:
J.A.DAVEY LTD
C/- Healthcare Logistics
Telephone: 0800 523 583
Website: www.jadavey.co.nz
Should you require any further
information please do not
hesitate to contact us.
DJL-RE06_Instruction-Manual.indd 12 16/08/2017 4:52 PM
Table of contents
Other BodiSure Massager manuals