Power Rating (RMS): 3 Independent amplifier channels rated at 100 watts (Amp 1),
60 watts (Amp 2), and 20 watts (Amp 3) RMS continuous
Frequency Response (Aux inputs):
Transformer Outputs — 70Hz to 20kHZ ±2dB (Amp 1& 2), 100Hz to 15kHz ±2dB (Amp 3)
4-
Ω
Direct — 20Hz to 20kHz ±2dB (Amp 1& 2), 20Hz to 15kHz ±2dB (Amp 3)
Distortion: Less than 0.5% (Less than 1% on Amp 3)
Signal-to-Noise Ratio: -70dBr (Tel and Aux); -55dBr (Mic)
Inputs: Mic — 2 Lo-Z balanced: Mic A has XLR-type connector, Mic B has screw
terminal strip and can be configured as a 600-ohm transformer-balanced input
for telephone paging applications
Aux — 4 unbalanced Aux inputs via RCA jacks
Mic Precedence: Via terminal strip. Programmable for Normally Open, Normally Closed or VOX
Outputs: Separate terminal strips for each channel provides 4- and 8-ohm output and
25V and 70V taps
Tone Controls: Bass — ±10dB @ 50Hz in 15 steps; Treble — ±10dB @ 15kHz in 15 steps
Preamp Out/Power Amp In: Separate link for each channel permits insertion of signal-processing equipment
Controls: Front-mounted, removable control panel with soft-touch buttons;Wireless
infrared remote control
User Mode: Permits control of volume, bass, treble, manual input selection
Programming Mode: Password-protected mode permits setting of system functions
Power Consumption: 430 watts
Dimensions: 17"W x 5-1/2"H x 14"D
Shipping Weight: 40 lbs.
Technical
Specifications
The amplifier shall be a Bogen ProMatrix Digitally Matrixed
Amplifier, Model PM3180. It shall incorporate three inde-
pendent amplifier channels rated at 20, 60, and 100 watts.
The user interface shall be all-digital and shall automatically
control the distribution of multiple program and paging
inputs to separate areas served by the amplifier.
The amplifier shall provide 2 Lo-Z balanced Mic inputs. It
shall be possible to configure Mic B as a 600-ohm trans-
former balanced input for telephone paging applications.
There shall be automatic level control for Mic inputs as well
as a choice of microphone precedence activation (VOX,
Normally Open, Normally Closed) and available phantom
power for use with condenser microphones.
There shall be 4 auxiliary inputs (RCA unbalanced). Input
trim controls shall be provided to adjust for differing audio
source input levels.
The amplifier shall provide for automatic switching of inputs
based on input activity. It shall be possible to assign a prior-
ity level for each input on each amplifier channel.
Each amplifier channel shall have separate 4- and 8-ohm out-
puts as well as 25 and 70 volt taps.Audio processing inserts
shall be included for each amp channel to facilitate the inser-
tion of external signal processing equipment. Front panel
mounted LED output level meters shall be provided for
each amp channel.
The amplifier shall provide automatic fade-in of audio
source after a microphone page or when switching to a
lower priority input. The paging over music level shall be
adjustable.
A front-mounted, removable control panel and a wireless
infrared remote control unit shall be provided.
There shall be two (2) modes of operation.The User mode
shall permit the selection of an amplifier channel to perform
the following operations: a) manual selection of an input
source; b) adjustment of volume level; c) adjustment of bass
and treble response. The Programming mode shall be pass-
word-protected and shall permit the following operations:
a) Assignment of priority levels; b) Set microphone prece-
dence activation, ALC, phantom power and mic/tel assign-
ment; c) Preset volume, bass and treble levels; d) Limit max-
imum volume for each amp/input combination; e) Inhibit
user’s ability to make volume or tone adjustments; f) Set
mute level of aux inputs during a microphone page; g) Set
audio processing link operation; h) Change program mode
password; i) Create custom display labels for input sources;
j) Reset all features to factory defaults.
All programming steps shall be displayed and verified on an
alphanumeric display panel. It shall be possible to program
the unit using the control panel or infrared remote control
unit. Non-volatile memory shall be used to retain user con-
trol settings.
The amplifier shall operate from a 110V AC source.The unit
shall be rack-mounted with optional mounting kit (RPK79).
The display panel shall be wall-mounted with optional
mounting kit (RMPWMK3).
Architect
and Engineer
Specifications
50 Spring Street, Ramsey, NJ 07446, U.S.A.
Tel. 201-934-8500; FAX: 201-934-9832; www.bogen.com