3.1 When the control system is powered on, by pressing this key the lamp can be turned
on and off.
3.2 The lamp will turn off automatically 2 hours after turned on.
4 Water cycle timer
4.1 Before using this function, the clock must be set correctly to ensure the accuracy of
the timer
4.2 The system has water cycle time period for setting. Before using this function, please
set the time period according to your needs.
4.3 The water cycle function will be turned on when the system time is in the time period
set. The water cycle function will stay off when the system time is not in the time
period.
5 Ozone
5.1 When the pump and blower are started, the ozone will be turned off.
5.2 When the pump and blower are off, and heating cycle pump or water cycle timer is on,
the ozone will be started automatically. When the heating cycle pump and water cycle
timer are turned off, the ozone will be automatically turned off.
6 Heating
6.1 When the system is powered on and the water temperature is lower than the set
temperature, the heating function will be started; when the water temperature reaches
the set temperature, the heating function will be turned off.
6.2 When the heating function is started, the heating circ pump is started in advance, and
the heater works later; When the heating function is turned off, the circ pump will be
shut down later.
7 Freeze proof
When the water temperature is below 6
℃
(
43
℉
)
, heating function will be started. The
heating function will be turned off when the temperature reaches 1
℃
(
5
℉
)
.