SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
NA_ENR_DAS240_CONF_VOIE Version: 1
SETTING A CHANNEL DAS240
The recorder DAS240, enable to record the following settings: voltage, current, resistance, temperature (with
a thermocouple, PT100 or PT1000).
We are going to see how to set an acquisition channel, with three examples:
1) Channel 1 configuration with a single voltage
2) Channel 2configuration with a K type thermocouple to measure an ambient temperature
3) Current configuration with a SHUNT resistor
I: Example voltage, setting the channel 1
1- Go to the channels validation by pressing the “Channels and functions On / Off” button:
2- Select the channel. Here we choose channel 1:
v
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
3- Go to the channel setting s by pressing on the channel to be set:
4- Set the type of measurement, here we measure the voltage:
5- Choose an adapted caliber for this voltage, in this example: 20V caliber :
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
6- Set the zero’s position, here we will use the “Min” position because we want to visualize a positive voltage.
The range will be 0 to 20V:
7- It’s possible to use a filter to remove the glitches, here we will choose 10 Hz:
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
8- Choose the acquisition period, in the example we will use a « 20 ms » sampling period (each channel can
have their own sampling period which is different of the sampling frequency of the recorder):
9- The configuration of the first channel is completed and we can visualized the signal:
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
II: Example K type thermocouple, set the channel 2
1- Go to the channels validation by pressing the “Channels and functions On / Off” button:
2- Select the channel. Here, the channel 2:
3- Go to the settings of the channel by pressing the channel to be set:
v
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
4- Choose the type of measurement, here we measure the temperature with a thermocouple:
5- Setting the type measurement:
1. Choose the thermocouple type, here we will use a K type thermocouple
2. Select the compensation
3. Choose the unit, here we will take the Celsius degree (°)
6- Choose an adapted caliber, in this example we will use a 30°C caliber:
2
3
1
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
7- Set the zero’s position, here we will use the “Min” position because we want to visualize the ambient
temperature. The range will be 0 to 30°C:
8- It’s possible to use a filter to remove the glitches, here we will choose 10 Hz:
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
9- Choose the acquisition period, in our example we will use a « 20 ms » sampling period, each channel can
have their own sampling period which is different of the sampling frequency of the recorder:
10-The configuration of the second channel is completed and we can visualized the signal:
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
III: Example current, setting the channel 3
1- Go to the channels validation by pressing the “Channels and functions On / Off” button:
2- Select the channel. Here, the channel 3:
3- Go to the channel settings by pressing the channel to be set:
v
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
4- Choose the measurement type, here we measure a current measurement:
5- To measure the current we will use a SHUNT resistor. Choose its value, here we will take a 50 Ωresistor:
6- Choose an adapted caliber, here: 1A caliber:
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
7- Set the zero’s position, here we will use the “Min” position because we want to visualize a positive current.
The range will from 0 to 1A:
8- It is possible to use a filter to remove the glitches, here we will choose 10 Hz:
SEFRAM INSTRUMENTS SAS - 32, rue E. Martel –BP55 - F42009 –Saint-Etienne Cedex 2 France
Tel: +33 (0)4 77 59 01 01 Fax : +33 (0)4 77 57 23 23
SAS au capital de 1 650 000 euros –RCS Saint-Etienne 790 833 404/ APE: 2651B / SIRET : 790 833 404 00011
TVA Intracommunautaire: FR 19790833404
9- Choose the acquisition period, in the example we will use a « 20 ms » sampling period, each channel can
have their own sampling period which is different of the sampling frequency of the recorder:
10-The configuration of the second channel is completed and we can visualized the signal:

Other B+K precision Measuring Instrument manuals

B+K precision 879B User manual

B+K precision

B+K precision 879B User manual

B+K precision 5335B User manual

B+K precision

B+K precision 5335B User manual

B+K precision 2831E User manual

B+K precision

B+K precision 2831E User manual

B+K precision 467 User manual

B+K precision

B+K precision 467 User manual

B+K precision 601B User manual

B+K precision

B+K precision 601B User manual

B+K precision 2831C User manual

B+K precision

B+K precision 2831C User manual

B+K precision 2652A User manual

B+K precision

B+K precision 2652A User manual

B+K precision 830C User manual

B+K precision

B+K precision 830C User manual

B+K precision PR-55 User manual

B+K precision

B+K precision PR-55 User manual

B+K precision 600B User manual

B+K precision

B+K precision 600B User manual

B+K precision BA8100 User manual

B+K precision

B+K precision BA8100 User manual

B+K precision 310 User manual

B+K precision

B+K precision 310 User manual

B+K precision 4070A User manual

B+K precision

B+K precision 4070A User manual

B+K precision BK603B User manual

B+K precision

B+K precision BK603B User manual

B+K precision 2650 User manual

B+K precision

B+K precision 2650 User manual

B+K precision 177/V-95 User manual

B+K precision

B+K precision 177/V-95 User manual

B+K precision 600B User manual

B+K precision

B+K precision 600B User manual

B+K precision 601 User manual

B+K precision

B+K precision 601 User manual

B+K precision 830C User manual

B+K precision

B+K precision 830C User manual

B+K precision RFM3000 Series User manual

B+K precision

B+K precision RFM3000 Series User manual

B+K precision 309 User manual

B+K precision

B+K precision 309 User manual

B+K precision 2708B User manual

B+K precision

B+K precision 2708B User manual

B+K precision 2530B User manual

B+K precision

B+K precision 2530B User manual

B+K precision 308A User manual

B+K precision

B+K precision 308A User manual

Popular Measuring Instrument manuals by other brands

Tascam TSR-8 operation & maintenance

Tascam

Tascam TSR-8 operation & maintenance

Kiwitron KiwiEye X001010 Installation, use and maintenance manual

Kiwitron

Kiwitron KiwiEye X001010 Installation, use and maintenance manual

REMA GGP-01 owner's manual

REMA

REMA GGP-01 owner's manual

UGT Tensio 140 operating manual

UGT

UGT Tensio 140 operating manual

Orbis CONTAX 6521 S0 quick start guide

Orbis

Orbis CONTAX 6521 S0 quick start guide

Hioki 9010 instruction manual

Hioki

Hioki 9010 instruction manual

Hanna Instruments HI 4101 instruction manual

Hanna Instruments

Hanna Instruments HI 4101 instruction manual

Ditel DINOS DT Series Quick installation guide

Ditel

Ditel DINOS DT Series Quick installation guide

Right Weigh 250 Series Installation & operation manual

Right Weigh

Right Weigh 250 Series Installation & operation manual

Mahr Millimar C 1200 operating instructions

Mahr

Mahr Millimar C 1200 operating instructions

Aichi Tokei Denki AS Series Handling manual

Aichi Tokei Denki

Aichi Tokei Denki AS Series Handling manual

Agilent Technologies ESA-E E4407B Installation note

Agilent Technologies

Agilent Technologies ESA-E E4407B Installation note

HHB Portadisc MDP500 Quick reference guide

HHB

HHB Portadisc MDP500 Quick reference guide

Velleman DVM321 user manual

Velleman

Velleman DVM321 user manual

Keysight Technologies BT2152B Operating and service guide

Keysight Technologies

Keysight Technologies BT2152B Operating and service guide

Landis & Gyr ULTRAHEAT T230 Operating and installation instruction

Landis & Gyr

Landis & Gyr ULTRAHEAT T230 Operating and installation instruction

SatisGeo KAPPAMETER KM-7 Operation guide

SatisGeo

SatisGeo KAPPAMETER KM-7 Operation guide

Sur-Gard SG SECURITY SG-DVT1 instruction manual

Sur-Gard

Sur-Gard SG SECURITY SG-DVT1 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.