BRB Systems USA TX-101 User manual

1
BRB Systems USA Co.
Instruction Manual
Fully Wireless Counter Release System
IMPORTANT: Read and understand this manual before assembling, installing or
using this system. Improper use of this system can cause serious injury.
Table Of Contents
(1) Safety Information…………………………………………………………………………….
(2) Installation…………………………………………………………………………………………
(3) Set Up
(3.1) Counter Set Up……………………………………………………………………..
(3.2) Receiver Set Up……………………………………………………………………
(3.3) Transmitter Set Up………………………………………………………………
(3.31) User Modes………………………………………………………………
(3.32) TX-101 Transmitter Button Layout Options…………..
(4) Operation
(4.1) Counter Operation……………………………………………………..
(4.2) RX-101 Receiver Operation……………………………………….
(4.3) TX-101 Transmitter Operation…………………………………..
(5) Counter Codes………………………………………………………………………………………..
(6) Maintenance……………………………………………………………………………………………..
(7) Warranty………………………………………………………………………………………………
2
4
7
8
10
10
11
16
18
18
21
22
23

2
(1) Safety Information
Make certain that any person assembling or installing this system has read and fully
understood this Instruction Manual. It is your guide to safe and proper operation of this
system.
TX-101 Transmitters are 6V powered by 4 AA batteries.
AA batteries are small but powerful and must be treated with respect. Never short
the ends of the battery together. Never burn the battery, even when you think it is
fully discharged.
RX-101 Receivers sold as 12V are to be powered with 12V dc power sources only.
The 12V dc power sources that may be used with the Receivers are; 12V lead acid
batteries, 12V regulated ac to dc power supplies and 12V dc power directly from the
trap.
RX-101 Receivers sold as 120V are to be powered with 120V ac power sources only.
Do not defeat the safety purpose of the polarized or grounding type plug fitted to
this apparatus. If the provided plug does not fit into your outlet consult a qualified
electrician. Exterior 120V outlets should be GFCI protected for your safety. If the
outlet is not GFCI protected then contact a qualified electrician for rectification.
System Counter components sold as 12V units are to be used with 12V dc power
sources only. The 12V dc power sources that may be used with the Counter units
are; 12V lead acid batteries, 12V regulated ac to dc power supplies and BRB Power
Packs.
12V lead acid batteries (such as car type batteries) contain acid and so extreme care
must be taken when handing them.
CAUTION:
This system is powered by electricity. To reduce the risk of electric shock, do
not remove any cover from the apparatus. There are no user serviceable parts
inside. Refer servicing to BRB Systems USA Co.
BRB Systems USA Co.

3
12V car batteries are capable of supplying large amounts of current and care must
be taken not to connect the + (red) and –(black) terminals together.
Protect the power cord from being walked on, pinched or damaged in any way.
Disconnect this apparatus from its power source during lightning storms or when
unused for extended periods of time.
Use only the attachment parts/accessories supplied by BRB Systems USA Co.
Do not allow liquid entry into the system components.
Ensure that the traps are disconnected from their power sources and unloaded
before connection of the Receiver or set up of the Transmitter. Failure to do so
could result in the unexpected operation of the trap causing serious injury.
Ensure that the trap is disconnected from its power source and unloaded and that it
is completely disconnected from the Receiver before attempting loading,
maintenance or repair of the trap. Failure to do so could result in the unexpected
operation of the trap causing serious injury.
Extreme caution must be taken when a manually loaded trap is in use.
This system is not able to determine whether a loader is ready for a target to be
launched. Inadvertent operation of the system may cause serious injury to the
loader.

4
(2) Installation
(2.1) Counter Unit
Installation of the Counter should be to the side or rear of the shooting position, in such a
place as not to obstruct or distract the shooter. The Counter unit should be mounted
either to a post, wall or tree and must be mounted vertically without obstruction between
the antenna and the trap house.
Three (3) hanger bolts, washers and wing nuts are supplied for mounting the Counter
enclosure. Once installed these allow for easy removal of the Counter for storage at the
end of the day.
To install the hanger bolts, place the Counter enclosure against the surface it is to be
mounted to and mark the positions of the 3 mounting holes through the box flanges. Drill
the appropriate size holes in the 3 marked positions. Using 2 wrenches, lock the 2 nuts
(supplied) against each other on the machine thread of the hanger bolt. Using a wrench,
turn the wood thread into the mounting surface, using the 2 locked nuts, until only the
machine thread can be seen. Unlock the 2 nuts from each other and remove them from
the bolt. When all are installed there will be 3 studs protruding from the mounting surface.
Slide the Counter enclosure over the studs and fit the wing nuts.
Counter Unit Connections
Battery Power
6ft 2 core cable with alligator clips or crimp ends = Counter power. Connect to battery.
Red = 12V +ve.
Black = 12V –ve.
BRB Power Pack
6ft cable with 3 pin plug = Power. Plug into BRB battery pack.

5
(2.2) RX-101 Receiver
Using the cabling as supplied, each RX-101 Receiver should be mounted vertically and
within 10ft of the power and release connections of the trap.
To lengthen the power/release cabling use a connector that is rated for outdoor use and
meets current electrical standards. Ideally the Receiver antenna should have an
unobstructed line of sight to the Transmitter antenna.
To make the Receiver connections to your traps, use the appropriate plug for the trap.
These parts can be purchased from your trap manufacturer or dealer. Release plug and
socket wiring diagrams for your trap can be obtained from your trap manufacturer or
dealer.
Receiver Connections –1Trap Receiver
Power From Trap
10ft long 4 core cable = Receiver power and trap release connections.
Red= 12V +ve.
Black= 12V –ve.
White and Green = trap release connections. Orientation of the white and green wires is
not important.
Power From 120Vac Wall Outlet
10ft 120V ac power cord = Receiver power.
Plug into GFCI protected 120V outlet.
10ft 2 core cable = trap release connections.
Orientation of the wires is not important.
Receiver Connections –2 Trap Receiver
Power From Trap
10ft 4 core cable = Receiver power and trap release connections.
Red= 12V +ve.
Black= 12V –ve.
White and Green = trap release connections Trap A. Orientation of the white and green
wires is not important.
2 pin socket and plug = trap release connections Trap B. Orientation of white and green
wires is not important.
Make solder connection of customer supplied cable into plug from Trap B.