Quick Setup
Adjusting The Differential
Fill the reservoir with a 20% propylene glycol
solution: 4 parts RO/distilled/deionized water to 1
part 99.9% propylene glycol.
• If you choose to use water only, it is best to use
tap water. RO/distilled/deionized water on its
own may damage the heat exchanger.
Plug in both temperature probes. The temperature
probes must be plugged in at all times, otherwise
you will get an error code.
Connect your cooling system outlet hose to the IN
bulkhead.
Connect your cooling system inlet hose to the OUT
bulkhead directly to the right.
Install the temperature probe in your thermowell,
or tape it directly to the outside of your vessel if it
does not have a thermowell.
The temperature dierential controls at what
point the pump will power on to begin a cooling
cycle. For example, if your SET temperature is 20°C
(68°F) and the temperature probe reading rises
to 20.5°C (68.9°F), the pump will power on and
recirculate cooling solution until the probe reading
drops back down to 20°C.
The default dierential setting is 0.5°C, but it can
be adjusted if desired.
To adjust this parameter, hold the ‘Up’ and ‘Down’
buttons simultaneously for 3 seconds. The rst
menu code F0 will appear on the display.
During normal operation, the number displayed
on the pump controller is the reading from the
temperature probe.
Adjust the SET temperature on the controller to
your desired fermentation temperature.
• To adjust the SET temperature, hold the ‘Up’
button for 3 seconds until the number is ashing.
While the number is ashing, press the ‘Down’
button to decrease the set temperature or press
the ‘Up’ button to increase the set temperature.
Wait 3 seconds and the controller will save the
setting a return to normal operation mode.
To adjust the reservoir temperature settings, please
see the instructions on the following page.
Press the ‘Up’ or ‘Down’ buttons to cycle through
the parameters until you reach F3 for the
dierential setting.
Press the ‘Up’ and ‘Down’ buttons simultaneously
to make adjustments to the parameter. Then press
either the ‘Up’ or ‘Down’ buttons change the set
value of the selected parameter.
Wait 5 seconds and the controller will save your
parameter setting and return to normal operation
mode.
1
1
2
2
3
3
4
4
5
5
6
6
7
8
Parameter Function Range Default Units
F0 SetPoint range -40.0 – 90.0 10.0 °C
F1 Minimum value for SetPoint -40.0 – F0 -40.0 °C
F2 Maximum value for SetPoint F0 –90.0 90.0 °C
F3 Cooling dierential 0.1 – 10.0 0.5 °C
F4 Heating dierential -10.0 – 10.0 0.5 °C
F5 Temperature probe calibration 1 – 10.0 0 °C
F6 Cooling start delay 0 – 300 1 Minute
F7 Cooling start delay aer power failure 1 – 10.0 10 Second
F8 Heating start delay 0 – 300 1 Minute
F9 Heating start delay aer power failure F11 – 99.9 10 Second
F10 Maximum temperature before alarm activation -45.0 – F10 90.0 °C
F11 Minimum temperature before alarm activation 1 – 120 -40.0 °C
F12 Alarm delay 1 Minute