manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BRIDGEWERKS
  6. •
  7. Power Supply
  8. •
  9. BRIDGEWERKS Mag 15 User manual

BRIDGEWERKS Mag 15 User manual

WARRANTY
Bridgewerks provides technical support free of charge, regardless of how long you have had your controller.
Somemes an issue can be xed over the phone, saving the cost of shipping and geng your railroad
running faster.
Parts and labor are warranted for a period of 5 years. If your Bridgewerks Product requires repair, ship it
back to Bridgewerks, We will repair or replace it and return it to you. If your warranty has expired, or is
not registered, there will be a charge for repair and shipping.
If a unit is returned for repair and no problem is found, there will be a $25 service charge.
Return Freight Policy: Customer is responsible for return freight; you will be advised the amount when
your unit is ready for return.
Warranty does not cover repairs to damage caused by misuse or abuse. Please do not leave this product
outdoors: unplug the quick disconnect plugs and bring it indoors when it is not in use.
Be sure to keep the packaging just in case your unit ever does need to be returned for service. Some of our
products are very heavy, and the special packaging is designed specically to protect the internal parts and
cosmecs of the product.
Please take a moment to ll out the Warranty card in the box or online at Bridgewerks.com and return it to
us.
Thank you.
BRIDGEWERKS
901 N Brutscher St Suite D383
Newberg, OR 97132
www.bridgewerks.com
Mag 15
Power Supply
Family owned and operated since 1995
Mag 15 Power Supply
• CONNECTIONS:
The MAG-15 is a linear power supply intended to provide up to 600 Was of power for model railroads,
and accessories
There are three outputs from the MAG-15.
• the primary output is a 20V regulated DC output, this can be used as a power source for
other power controllers such as the Bridgewerks Mag-Mate, or UR-15, or for third party
control systems such as DCC systems.
• There is an unregulated, 12V output from the power supply,
• There is a 24V AC output
• Overload Protecon:
In the event of an overload, the circuit is protected by a reseable fuse on the back of the unit. If it trips,
turn o the power, wait for a few minutes, remove whatever caused the overload, then press the buon
on the back of the unit to reset the fuse, and turn on the power again.
• Wire:
Use heavy gauge wire to connect your power controller to the track. For distances of up to 15 feet,
you should use 12 gauge wire. For distances over 15 , you use 10 gauge wire. Although the track
itself is similar to a very heavy gauge wire, in larger layouts, signicant loss can occur from the
connecons between secons of track. To improve this, run mulple power connecons to the
track from the controller and/or use track clamps rather than slider type couplers. In outdoor
layouts which are exposed to extreme temperatures, the track will expand and contract as the
temperature changes, and slider type couplers may have to be used.
• Outdoor operaon
Garden railways are oen installed outdoors and Bridgewerks controllers are built to be used with
outdoor railroad layouts. However, they are not waterproof, and as with any electronic equipment,
they should not be le outdoors when not in use. To make this easy, the connecons are all made so
that they can simply be unplugged and the controller can be carried indoors.

Popular Power Supply manuals by other brands

EVGA 80 PLUS BRONZE 500 BQ user manual

EVGA

EVGA 80 PLUS BRONZE 500 BQ user manual

Digitrax PS2012 manual

Digitrax

Digitrax PS2012 manual

Valcom VP-2048C datasheet

Valcom

Valcom VP-2048C datasheet

Neuralynx Lynx-8 user manual

Neuralynx

Neuralynx Lynx-8 user manual

Ultra Products ULT31312 Features

Ultra Products

Ultra Products ULT31312 Features

REO REOTRON SMP CP Series instruction manual

REO

REO REOTRON SMP CP Series instruction manual

Mastech HY3000M Series user manual

Mastech

Mastech HY3000M Series user manual

Altronix WayPoint104 installation guide

Altronix

Altronix WayPoint104 installation guide

California Instruments FCS Series II user manual

California Instruments

California Instruments FCS Series II user manual

THORLABS GPS011-EC Original instructions

THORLABS

THORLABS GPS011-EC Original instructions

Magnetek 144-45117-R3 instruction manual

Magnetek

Magnetek 144-45117-R3 instruction manual

Keithley 2260B Series Programming manual

Keithley

Keithley 2260B Series Programming manual

Bpt VA/01 instructions

Bpt

Bpt VA/01 instructions

EcoFlow River user manual

EcoFlow

EcoFlow River user manual

EFLOW eFlow3NV installation guide

EFLOW

EFLOW eFlow3NV installation guide

LEYBOLD 521 50 instruction sheet

LEYBOLD

LEYBOLD 521 50 instruction sheet

Puls PIANO PIM36.241 manual

Puls

Puls PIANO PIM36.241 manual

StarTech.com ATXPOWER400 Instruction guide

StarTech.com

StarTech.com ATXPOWER400 Instruction guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.