Make sure all knobs are in the “OFF” position.
The main gas valve should be “CLOSED/OFF” for five minutes prior to relight the appliance to
clear any exiting gas. (Main gas valve is supplied by others.)
Turn “ON/OPEN” the main gas valve to the unit.
Light and hold an ignition source (match) at the pilots. When the flame is established, remove
the ignition source. Repeat this step for each burner as each burner has its own individual
pilot. The pilot can be reached through the holes in the front of the unit.
Adjust the pilot valve, make sure the pilot flame is at 1/2 inch height.
Turn each burner knob “ON”. If the burners do not ignite promptly, turn the Knobs ”OFF”,
from the opening in the front panel, use a screwdriver and turn the pilot valve screw
counterclockwise which will increase the flame height and repeat step 4. The pilot flame
should be as small as possible but large enough to guarantee reliable ignition of the burners
when the knobs are turned to “ON”. The holes located in the front panel are pilot valve
adjustments. Use a screwdriver to turn the valve to adjust the flame height to your desired
level.
TO COMPLETELY SHUTDOWN THE BURNERS AND PILOT LIGHTS
For complete shutdown: Turn the main gas supply valve OFF
1
2
3
4
5
6
7
The burner is in two sections, controlled by two heavy duty infinite control valves. The center “Star”
section (Fig.6) is on a separate burner with an input of 40,000 btu/hr. It is controlled by the right burner
valve knob. The outer circle of the burner is the other separate 40,000 btu/hr input burner, controlled
by the left burner valve knob.
These two separate burners provide heat flexibility. With one burner off and the second burner set low,
up to both burners full on, you can move from low simmer on up to 80,000 btu/hr input.
FIG 6
FIG 5
CONTROLS
10www.brikaequipment.ca
LIGHTING INSTRUCTIONS