Round Pin And Export Socket Outlets
Installation Information
Safety Warning
Before use please read carefully and use in accordance with these safety wiring instructions.
Before commencing any electrical work ensure the supply is switched off at the mains. Either by switching off the consumer unit or by removing the appropriate fuse.
Wiring should be in accordance with the latest edition of the IEE regulations (BS 7671).
Wire Identification – Twin & Earth Cable
EARTH = Green/Yellow Sleeving
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04)
LIVE = Red (pre Apr 04) / Brown (after Apr 04)
The ends of the individual conductors should have the insulation removed by approx.12mm. Any bare earth conductors should be sleeved to within 12mm of the ends.
(These details are for general information only and conductor lengths may need to be trimmed in certain installations).
Technical Helpline: 0845 194 7584
If in doubt consult a competent electrician.
General Installation Instructions
1) If using the new product to replace an old one, note the cable connections and wire up new product in the same way as the old one, with Earthing as stated in these instructions.
2) Ensure the mounting box (metal or patress) for either flush or surface mounting is the appropriate size for the product.
3) Route the cable through the most suitable entry point of the mounting box. If a metal box is used, a protective cable grommet should be used.
4) Cables should be prepared so a sufficient conductor length reaches the terminals. Strip the ends of the individual conductors so that an adequate length enters the terminals.
5) Carefully arrange the wiring to lie along the edges of the product or box, keeping the central area clear.
6) To assist with the correct installation please consult the appropriate wiring diagram on this leaflet.
7) When connecting the new accessory ensure that only the bare end of the wire enters the terminal, and no bare wires are visible.
Always tighten the terminal screws securely, but do not overtighten.
An earth connection should always be made between the mounting box earth terminal, and the accessory earth terminal, where fitted. If this earth wire is bare, it is essential that it is sheathed
with a length of green/yellow sleeving.
8) Carefully position the accessory into the wall box, ensuring that no wires are trapped between the plate and the wall. Do not overtighten the screws. (Fit screw covers + clip-on)
9) Once work has been completed correctly, replace the fuse for the circuit, switch the power back on, and test.
The product is now ready for use.
* Note - If your installation uses a four lug metal mounting box, remove the top and bottom lugs or bend fully back.
Decorative Front Plate Fixing
Fixing method varies depending on which product range is supplied. Always ensure wall surface is reasonably flat and smooth, with no bumps or projections.
Metal Front plates WITH screw fixing holes. These products comprise main unit with integral front plate and rear gasket. Fix unit to back box using two fixing screws supplied.
Front plates WITHOUT screw fixing holes. These products comprise main unit with integral gasket, and front plate as separate item. Fix unit to back box using two fixing screws supplied.
Clip front plate onto main assembly, ensuring screwdriver notch is located bottom right hand corner. To remove plate, place medium size flat bladed screwdriver in notch and lever off against
gasket.
For all Decorative Plates - It is essential the gasket is fitted between product and wall, to reduce possibility of discolouration of front plate edges due to natural moisture in some wall finishes.
To keep the finish of this product, wipe over with soft cloth periodically.
All Decorative products MUST have an earth connection between the front-plate and back box
NBS28G
NBS28W
NPC28W
NPB28B
NBN28B
NBS29G
NBS29W
NPC29W
NPB29B
NBN29B
NBS27G
NBS27W
NPC27W
NBS99G
NBS99W
NPC99W
NPB99B
NBN99B
NBS98G
NBS98W
NPC98W
NPB98B
NBN98B
NPB27B
NBN27B
2A 1G, USW SKT
2A 1G, USW SKT
2A 1G, USW SKT
2A 1G, USW SKT
2A 1G, USW SKT
5A 1G, USW SKT
5A 1G, USW SKT
5A 1G, USW SKT
5A 1G, USW SKT
5A 1G, USW SKT
13A 1G UNI SKT
13A 1G UNI SKT
13A 1G UNI SKT
15A 1G, SW SKT
15A 1G, SW SKT
15A 1G, SW SKT
15A 1G, SW SKT
15A 1G, SW SKT
16A 2G Euro SKT
16A 2G Euro SKT
16A 2G Euro SKT
16A 2G Euro SKT
16A 2G Euro SKT
13A 1G UNI SKT
13A 1G UNI SKT
13A 1G UNI SKT
5050765018906
5050765028424
5050765020015
5050765021128
5050765023214
5050765018913
5050765028455
5050765020022
5050765021135
5050765023221
5050765018920
5050765028486
5050765020039
5050765021142
5050765023238
5050765018937
5050765028516
5050765020046
5050765021159
5050765023245
5050765019279
5050765028431
5050765020381
5050765021494
5050765023580
5050765019286
5050765028462
5050765020398
5050765021500
5050765023597
5050765019293
5050765028493
5050765020404
5050765021517
5050765023603
5050765019309
5050765028523
5050765020411
5050765021524
5050765023610
5050765019644
5050765028448
5050765020756
5050765021869
5050765023955
5050765019651
5050765028479
5050765020763
5050765021876
5050765023962
5050765019668
5050765028509
5050765020770
5050765021883
5050765023979
5050765019675
5050765028530
5050765020787
5050765021890
5050765023986
Cat No. Cat No.Description Description
Individual IndividualInner Box Inner BoxOuter Box Outer Box
Barcode Barcode
Packaging Information
To maintain the high quality appearance of decorative finish switches and sockets, BG Electricals recommend the use of a soft cloth periodically to clean the front face. When installing a decora-
tive product please ensure that the wall is decorated, finished and free of moisture prior to installation. Please note that it can take several weeks for the chemicals in paint or wallpaper paste to
become inert. Before this time there is a danger that they will react with the product if it has a metal faceplate.
BG recommends avoiding using, but not restricted to, the substances from becoming in contact with the decorative metal front-plates when cleaning or decorating;
• Adhesive tape, including masking tape
• Solvents
• White spirit
• Multi surface cleaners
• Industrial multipurpose cleaning wipes
• Wet wipes
Using these items like those listed above may cause a degrading effect to the front-plates lacquer/plated finish, although the function will remain unaffected.