manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. British General
  6. •
  7. Accessories
  8. •
  9. British General NBS28G Instruction manual

British General NBS28G Instruction manual

Technical Data
Round Pin And Export Socket Outlets
Brief product description:
A sleek and slim design with softly rounded corners will
compliment any interior décor - suitable for domestic or
commercial installations.
Will accept BS, USA & CEE plugs
Features:
• Fixed integrated plastic gasket to protect metal
edges from moisture
• Stylish modern profile
• Available in 4 metal finishes
• Colour matched fixing screws
• Colour coded terminals for easy installation
Product Images
Black Nickel
Polished Chrome
Polished Brass
Brushed Steel
NBN28B
NPC28W
NPB28B
NBS28G
NBS28W
NBN29B
NPC29W
NPB29B
NBS29G
NBS29W
NBN98B NBN27B
NPC98W NPC27W
NPB98B NPB27B
NBS98G NBS27G
NBS98W NBS27W
NBN99B
NPC99W
NPB99B
NBS99G
NBS99W
Round Pin And Export Socket Outlets
Standard(s)
Rating
Terminal Capacity
RoHS Directive
WEEE Directive
Mounting Box Depth(Min)
Fixing Centres
Size
BS 546
2 Amp 250V~
4 x 1.0mm² 3 x 1.5mm² 1 x 2.5mm² 1 x 4.0mm²
No
No
25mm (Nxx28x, Nxx29x, Nxx98x products)
35mm (Nxx99x product)
60.3mm
86mm x 86mm x 24mm (Nxx28x product)
86mm x 86mm x 23.6mm (Nxx29x product)
86mm x 86mm x 31mm (Nxx99x product)
86mm x 86mm x 25.2mm (Nxx98x product)
Technical Specifications
Cat No. Description
Each Inner
Box
Outer
Box
Pack Quantity
Weights & Dimensions
Weight (g)
Each Inner
Box
Outer
Box
Dimension (W x L x H) cm
Product Inner Box Outer Box
CMB (m3)
Outer Box
Nxx28x
Nxx29x
Nxx99x
Nxx98x
Nxx27x
2A 1G, USW SKT
5A 1G, USW SKT
15A 1G, SW SKT
16A 2G Euro SKT
13A 1G UNI SKT
1
1
1
1
1
5
5
5
5
5
50
50
50
50
50
18 x 19 x 12
18 x 19 x 12
18 x 19 x 12
18 x 19 x 12
18 x 19 x 12
0.044896
0.044896
0.044896
0.044896
0.044896
36.8 x 61 x 20
36.8 x 61 x 20
36.8 x 61 x 20
36.8 x 61 x 20
36.8 x 61 x 20
Line Diagrams
Nxx28x
Nxx27x
Nxx98x
Nxx29x
Nxx99x
Round Pin And Export Socket Outlets
Installation Information
Safety Warning
Before use please read carefully and use in accordance with these safety wiring instructions.
Before commencing any electrical work ensure the supply is switched off at the mains. Either by switching off the consumer unit or by removing the appropriate fuse.
Wiring should be in accordance with the latest edition of the IEE regulations (BS 7671).
Wire Identification – Twin & Earth Cable
EARTH = Green/Yellow Sleeving
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04)
LIVE = Red (pre Apr 04) / Brown (after Apr 04)
The ends of the individual conductors should have the insulation removed by approx.12mm. Any bare earth conductors should be sleeved to within 12mm of the ends.
(These details are for general information only and conductor lengths may need to be trimmed in certain installations).
Technical Helpline: 0845 194 7584
If in doubt consult a competent electrician.
General Installation Instructions
1) If using the new product to replace an old one, note the cable connections and wire up new product in the same way as the old one, with Earthing as stated in these instructions.
2) Ensure the mounting box (metal or patress) for either flush or surface mounting is the appropriate size for the product.
3) Route the cable through the most suitable entry point of the mounting box. If a metal box is used, a protective cable grommet should be used.
4) Cables should be prepared so a sufficient conductor length reaches the terminals. Strip the ends of the individual conductors so that an adequate length enters the terminals.
5) Carefully arrange the wiring to lie along the edges of the product or box, keeping the central area clear.
6) To assist with the correct installation please consult the appropriate wiring diagram on this leaflet.
7) When connecting the new accessory ensure that only the bare end of the wire enters the terminal, and no bare wires are visible.
Always tighten the terminal screws securely, but do not overtighten.
An earth connection should always be made between the mounting box earth terminal, and the accessory earth terminal, where fitted. If this earth wire is bare, it is essential that it is sheathed
with a length of green/yellow sleeving.
8) Carefully position the accessory into the wall box, ensuring that no wires are trapped between the plate and the wall. Do not overtighten the screws. (Fit screw covers + clip-on)
9) Once work has been completed correctly, replace the fuse for the circuit, switch the power back on, and test.
The product is now ready for use.
* Note - If your installation uses a four lug metal mounting box, remove the top and bottom lugs or bend fully back.
Decorative Front Plate Fixing
Fixing method varies depending on which product range is supplied. Always ensure wall surface is reasonably flat and smooth, with no bumps or projections.
Metal Front plates WITH screw fixing holes. These products comprise main unit with integral front plate and rear gasket. Fix unit to back box using two fixing screws supplied.
Front plates WITHOUT screw fixing holes. These products comprise main unit with integral gasket, and front plate as separate item. Fix unit to back box using two fixing screws supplied.
Clip front plate onto main assembly, ensuring screwdriver notch is located bottom right hand corner. To remove plate, place medium size flat bladed screwdriver in notch and lever off against
gasket.
For all Decorative Plates - It is essential the gasket is fitted between product and wall, to reduce possibility of discolouration of front plate edges due to natural moisture in some wall finishes.
To keep the finish of this product, wipe over with soft cloth periodically.
All Decorative products MUST have an earth connection between the front-plate and back box
NBS28G
NBS28W
NPC28W
NPB28B
NBN28B
NBS29G
NBS29W
NPC29W
NPB29B
NBN29B
NBS27G
NBS27W
NPC27W
NBS99G
NBS99W
NPC99W
NPB99B
NBN99B
NBS98G
NBS98W
NPC98W
NPB98B
NBN98B
NPB27B
NBN27B
2A 1G, USW SKT
2A 1G, USW SKT
2A 1G, USW SKT
2A 1G, USW SKT
2A 1G, USW SKT
5A 1G, USW SKT
5A 1G, USW SKT
5A 1G, USW SKT
5A 1G, USW SKT
5A 1G, USW SKT
13A 1G UNI SKT
13A 1G UNI SKT
13A 1G UNI SKT
15A 1G, SW SKT
15A 1G, SW SKT
15A 1G, SW SKT
15A 1G, SW SKT
15A 1G, SW SKT
16A 2G Euro SKT
16A 2G Euro SKT
16A 2G Euro SKT
16A 2G Euro SKT
16A 2G Euro SKT
13A 1G UNI SKT
13A 1G UNI SKT
13A 1G UNI SKT
5050765018906
5050765028424
5050765020015
5050765021128
5050765023214
5050765018913
5050765028455
5050765020022
5050765021135
5050765023221
5050765018920
5050765028486
5050765020039
5050765021142
5050765023238
5050765018937
5050765028516
5050765020046
5050765021159
5050765023245
5050765019279
5050765028431
5050765020381
5050765021494
5050765023580
5050765019286
5050765028462
5050765020398
5050765021500
5050765023597
5050765019293
5050765028493
5050765020404
5050765021517
5050765023603
5050765019309
5050765028523
5050765020411
5050765021524
5050765023610
5050765019644
5050765028448
5050765020756
5050765021869
5050765023955
5050765019651
5050765028479
5050765020763
5050765021876
5050765023962
5050765019668
5050765028509
5050765020770
5050765021883
5050765023979
5050765019675
5050765028530
5050765020787
5050765021890
5050765023986
Cat No. Cat No.Description Description
Individual IndividualInner Box Inner BoxOuter Box Outer Box
Barcode Barcode
Packaging Information
To maintain the high quality appearance of decorative finish switches and sockets, BG Electricals recommend the use of a soft cloth periodically to clean the front face. When installing a decora-
tive product please ensure that the wall is decorated, finished and free of moisture prior to installation. Please note that it can take several weeks for the chemicals in paint or wallpaper paste to
become inert. Before this time there is a danger that they will react with the product if it has a metal faceplate.
BG recommends avoiding using, but not restricted to, the substances from becoming in contact with the decorative metal front-plates when cleaning or decorating;
• Adhesive tape, including masking tape
• Solvents
• White spirit
• Multi surface cleaners
• Industrial multipurpose cleaning wipes
• Wet wipes
Using these items like those listed above may cause a degrading effect to the front-plates lacquer/plated finish, although the function will remain unaffected.
Round Pin And Export Socket Outlets
Installation Information
2 Amp Unswitched Socket
Connect the cables as shown in the diagram.
5 Amp Unswitched Socket
Connect the cables as shown in the diagram.
15 Amp Switched Socket
Connect the cables as shown in the diagram.
2 Gang Euro Socket
Connect the cables as shown in the diagram.
FROM SUPPLY
FROM SUPPLY
FROM SUPPLY
LIVE
LIVE
LIVE
EARTH
EARTH
EARTH
NEUTRAL
NEUTRAL
NEUTRAL
All earth wires must be sleeved
and terminated to the back box
All earth wires must be sleeved
and terminated to the back box
All earth wires must be sleeved
and terminated to the back box
All earth wires must be sleeved
and terminated to the back box
E
L N
E
L N
E
L N L
E
N
FROM SUPPLY
LIVE EARTH NEUTRAL
Universal Switched Socket
Connect the cables as shown in the diagram.
FROM SUPPLY
LIVE EARTH NEUTRAL
All earth wires must be sleeved
and terminated to the back box
LEN

This manual suits for next models

73

Other British General Accessories manuals

British General NEXUS MC554 RCD Operating instructions

British General

British General NEXUS MC554 RCD Operating instructions

British General Nexus Moulded 822BELL User manual

British General

British General Nexus Moulded 822BELL User manual

British General SBS21G Instruction manual

British General

British General SBS21G Instruction manual

British General PCxx22U3 Series Instruction manual

British General

British General PCxx22U3 Series Instruction manual

British General FBS28G Instruction manual

British General

British General FBS28G Instruction manual

British General 821 Instruction manual

British General

British General 821 Instruction manual

Popular Accessories manuals by other brands

Conair SNSC26CTXC manual

Conair

Conair SNSC26CTXC manual

Flexco Flex-Lag Rubber Installation, operation and maintenance manual

Flexco

Flexco Flex-Lag Rubber Installation, operation and maintenance manual

ROSE DISPLAYS ANOQUICK ROUND WITH MULTICLIPS instruction sheet

ROSE DISPLAYS

ROSE DISPLAYS ANOQUICK ROUND WITH MULTICLIPS instruction sheet

Level Pro 300 Series installation manual

Level Pro

Level Pro 300 Series installation manual

Grundfos WIO sensor Installation and operating instructions

Grundfos

Grundfos WIO sensor Installation and operating instructions

Valor APR-101012 Series user guide

Valor

Valor APR-101012 Series user guide

TeraBee TeraRanger Evo Series user manual

TeraBee

TeraBee TeraRanger Evo Series user manual

Lennox 47W36 installation instructions

Lennox

Lennox 47W36 installation instructions

Intra Automation Itabar IBF operating manual

Intra Automation

Intra Automation Itabar IBF operating manual

Chamberlain 915GA install guide

Chamberlain

Chamberlain 915GA install guide

Lightolier AF2FR specification

Lightolier

Lightolier AF2FR specification

MHZ CLASSIC manual

MHZ

MHZ CLASSIC manual

Omron SYSMAC C200H Operation manual

Omron

Omron SYSMAC C200H Operation manual

Cover Pools Save-T Cover II owner's manual

Cover Pools

Cover Pools Save-T Cover II owner's manual

daviteq WSSFC-V1A-025 manual

daviteq

daviteq WSSFC-V1A-025 manual

Jorjin MM5D91-00 installation guide

Jorjin

Jorjin MM5D91-00 installation guide

Furman AIS-10E instruction sheet

Furman

Furman AIS-10E instruction sheet

SCE ENVIRO-THERM SCE-TE170B24VSS user manual

SCE

SCE ENVIRO-THERM SCE-TE170B24VSS user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.