Broadata Link Bridge LBS Series User manual

LBS-1616
LINK BRIDGE
TM
UNIVERSAL
16X16 OPTICAL/DVI/HDMI
MATRIX SWITCH
BCI reserves the right to make changes to the products described herein without
prior notice or consent. No liability is assumed as a result of their use or
application. All rights reserved.
©2013 Broadata Communications, Inc.

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
SAFETY INSTRUCTIONSANDCOMPLIANCE DECLARATIONS
PLEASE OBSERVE THE FOLLOWING SAFETY PRECAUTIONS AS OUR
PRODUCTS CONTAIN
CLASS I LASER PRODUCTS
WARNING
This product is a CLASS I LASERPRODUCT only when the units are connected
with a fiber optical cable. Do not disconnect the fiber optic connector while
the unit is powered up. Exposure to laser radiation is possible when the
laser fiber optic connector is disconnected while the unit is powered up. It
should be noted that when the fiber is disconnected, the product will have
CLASSIMINVISIBLELASERRADIATION.
Although the fiber optic connectors in this product emit only Class 1 energy
that is below the levels considered to be hazardous, one should never stare
directly into a fiber optic connector or an unconnected fiber end unless one
can be certain that no exposure to laser energy could occur.
CAUTION
Only service personnel are intended to access the interior of the units. It
should be cautioned that CLASS 3 INVISIBLE LASER RADIATION WHEN
OPEN, AVOID EXPOSURE TO THE BEAM. The use of controls, making
adjustments, or performing operations other than those specified may result
in hazardous radiation exposure. This product has operating wavelengths
at 778nm, 800nm with average -0.5dB to 0dBm optical power per wavelength,
825nm, 911nm, and 980nm. The laser is operated in pulse mode within 1
KHz frequency and ¼ duty cycle.
The following label or equivalent is located on the surface of laser products.
This label indicates that the product is classified as a CLASS 1 LASER
PRODUCT.
SURGEPROTECTION DEVICERECOMMENDED
This product contains sensitive electrical components that may be damaged
by electrical spikes, surges, electric shock, lightning strikes, etc. Use of
surge protection systems is highly recommended in order to protect and
extend the life of your equipment.

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
Broadata Technical Support, (800) 214-0222
4
TABLE OF CONTENTS
1.0 PRODUCT DESCRIPTION ............................................. 5
2.0 OPERATION CONTROLS AND FUNCTIONS ............... 6
2.1 FRONT PANEL ................................................................ 6
2.2 REAR PANEL ................................................................... 8
3.0 SWITCH CONTROL ........................................................ 9
3.1 RS-232 PIN ASSIGNMENT............................................. 9
3.2 RS-232 AND TELNET COMMANDS............................ 10
3.3 TELNET CONTROL ..................................................... 11
3.4 WEB GUI CONTROL .................................................... 13
4.0 SPECIFICATIONS .......................................................... 15
5.0 SERVICE PROCEDURE................................................ 17
5.1 REPLACEMENT POLICY.............................................. 17
5.2 RETURN AND REPAIR SERVICE ................................. 17
6.0 LIMITED WARRANTY .................................................... 18
7.0 APPENDIX...................................................................... 19

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
1.0 PRODUCT DESCRIPTION
The LBS Series is a high performance Link BridgeTM Universal Matrix
Switcher System that provides up to 16x16 video switching for HDMI/
DVI signals. It supports 12-bit deep color resolutions up to 1080p and
1920x1200@60Hz with multi-channel digital audio, such as LPCM 7.1CH,
Dolby TrueHD, Dolby Digital Plus and DTS-HD. Standard versions of the
LBS support all optical switching, or hybrid optical/electrical switching,
for HDMI/DVI signals. When configured for optical switching, only one
fiber is required per input or output port. In addition, the distance between
the switch and HDMI/DVI devices can be up to 400m when connected
by fiber cable. The I/O ports in the LBS can be configured in multiples of
8, thus supporting 8x8, 8x16, up to 16x16 matrix size. Appendix B
describes the I/O cards available for LBS Universal Matrix Switcher.
The LBS comes in a 3-RU packaging design, and has option for single
or dual power supply.
The LBS supports jitter-free, high-quality HDMI/DVI Display with several
EDID functions for independent display resolution at per-port basis. Types
of switching control available: manual control panel, standard
RS-232, or Ethernet Web GUI and Telnet control.

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
Broadata Technical Support, (800) 214-0222
6
2.0 OPERATION CONTROLS AND FUNCTIONS
2.1 Front Panel
1LOCK LED: This LED will illuminate when the on-panel key
functions is set to lock.
2POWER LED: This red LED will illuminate when the device is
set to standby mode, when it is flashing it means the temperature
inside is too high and air circulation is highly suggested.
3LCD: Displays the setting information of each input and output
and other setting information according to the selection.
4POWER: Press this button to turn on the device or to set it to
standby mode.
5UNDO: Press this button to return back/exit the current
selection.
6PAGE UP, PAGE DOWN,
,
: Use these buttons to flip the
LCD’s page for displaying the current I/O status or when entering
into the menu for detail selection.
3
5
12
4
7
6
810 9
11
12
13
14

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
7CONFIG: Press this button to enter into the menu selections of
A. EDID Setting
Standard EDID: Use the built-in EDID which supports video
up to 1080p@60/WUXGA@60Hz.
Auto EDID: based on the TV/Display’s EDID
of the lowest connected output port.
Manual EDID: Support independent EDID by assigning the
selected input port to the selected output port.
B. IP Configuration
1. IP address,
2. Netmask,
3. Gateway.
C. Temperature
T1, T2: these figures shows the temperature inside the device.
D. LCD Contrast Range from 1~4
8ALL: Press this button to select all outputs to one input.
90~9: Press these numbers when selecting input output ports.
10 IN/OUT: Press this button to select input source to switch to
output display. The sequence should be IN/OUT-number of input
source-IN/OUT-number of output display-Enter. (This button
works only under In/Out function)
11 LOCK: Press this button to lock all the function buttons on
panel. To unlock, press and hold lock button for 4 seconds.
12 SAVE: Press this button to save the present setting of the I/O.
There are 10 pre-sets available for saving.
13 RECALL: Press this button to recall from the saving settings of
1~10.
14 ENTER: Press this button every time to confirm the setting or
the selection.

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
Broadata Technical Support, (800) 214-0222
8
2.2 Rear Panel
1OUTPUT 1~16: Connect HD/3D display TV/monitor with HDMI
cables up to 16 displays.
2CPU
a. USB: This port is reserved for firmware update
only.
b. IR IN: Reserved.
c. ETHERNET: Connect to an active network line for LAN
and Telnet/Web GUI control.
d. RS-232: Connect with D-Sub 9-pin cable from the
PC/Control device for RS-232 control over the LBS-1616.
3INPUT 1~16: Connect source equipment such as Blu-ray/PS3
players up to 16 devices with HDMI/optical cable.
4POWER & POWER Supply: The device will automatically be
placed on stand-by mode when the power supply is connected
to AC power.
5Ventilation Fan: This fan will automatically turn on when the
device is switched ON. Do not block this port of the device or
cover it with any object. Please allow adequate space around
the unit for air circulation.
ETHERNET IR IN USB
RS232 OUTPUT 0
1
2
3
45

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
3.0 SWITCH CONTROL
3.1 RS-232 Pin Assignment
Default Port Settings
Baud Rate: 19.2K
Data Bits: 8
Parity Bits: None
Stop Bits: 1
Flow Control: None
PIN
1
2
3
4
5
6
7
8
9
Definition
NC
TxD
RxD
NC
GND
NC
NC
NC
NC
LBS-3232
PIN
1
2
3
4
5
6
7
8
9
Definition
NC
RxD
TxD
NC
GND
NC
NC
NC
NC
Remote Controller

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
Broadata Technical Support, (800) 214-0222
10
3.2 RS-232 and Telnet Commands
Refer to Appendix A for full list of commands.

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
3.3 Telnet Control
Before attempting to use the telnet control, please ensure that
both the Matrix (via the ‘LAN /CONTROL’ port) and the PC/Laptop
are connected to the active networks.
Note: Please do not connect both the Matrix and the PC/Laptop
with a single CAT5e/6 cable together as it will not access the
telnet function.
To access the telnet control in Windows 7, click on the ‘Start’
menu and type “cmd” in the Search field then press enter.
Under Windows XP go to the ‘Start’ menu and click on “Run”,
type “cmd” with then press enter.
Under Mac OS X, go to Go-Applications-Utilities-Terminal. See
below for reference.

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
Broadata Technical Support, (800) 214-0222
12
Once in the command line interface (CLI) type “telnet”, the IP
address of the unit you wish to control, then hit enter.
Note: The IP address of the Matrix can be displayed on the
device’s LCD monitor by pressing the “Config” button twice,
then ENTER.
This will bring us into the device which we wish to control. Type
“HELP” to list the available commands.
Type “IPCONFIG” To show all IP configurations. To reset the IP,
type “RSTIP” and to use a set static IP, type “SETIP” (For a full
list of commands, see Appendix A).

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
Note: Commands will not be executed unless followed by a
carriage return. Commands are not case-sensitive. If the IP is
changed then the IP Address required for Telnet access will
also change accordingly.
3.4 Web GUI Control
On a PC/Laptop that is connected to the same active network
as the Matrix, open a web browser and type device’s IP address
on the web address entry bar. The browser will display the
device’s status, control and User setting pages.

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
Broadata Technical Support, (800) 214-0222
14
Click on the ‘Control’ tab to control power, input/output ports,
EDID and reset mode.
Clicking on the ‘User Setting’ tab allows you to reset the IP
configuration. The system will ask for a reboot of the device
every time any of the settings are changed. The IP address
needed to access the Web GUI control will also need to be
changed accordingly on the web address entry bar.

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
4.0 SPECIFICATIONS
Matrix Switch
Array Size Up to 16x16 (configurable by
multiple of 8)
EDID Control Built-in Internal Standard EDID
HDMI/DVI Ports*
Signal Single Link DVI 1.1, HDMI 1.3
Resolution Up to 1080p or 1920x1200@60Hz
Connector DVI or HDMI Female Plugs
Protocol EDID/DDC and HDCP Capable
HDBT Ports
Cable Type CAT-5e/6 or higher
Connector RJ-45
Fiber Ports
Fiber Type Multimode 50um or 62.5um
Connector SC
Protocol EDID/DDC and HDCP Capable
Control
Manual Panel Button
RS-232 DB-9, 19.2 kb/s
Ethernet 10/100Base-T for Web
Browser, Telnet

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
Broadata Technical Support, (800) 214-0222
16
Physical
Dimension (H x W x D) 5.25” x 19.0” x 13”,
Including chassis handle
Power Level 110 VAC~240VAC, 50/60Hz
450W (max.) with all
optical ports
250W (max.) without
optical ports
Operating Temperature 0 to +40oC
Humidity 0 to 90% RH, non-condensing

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
5.0 SERVICE PROCEDURE
5.1 Replacement Policy
Standard products found defective on arrival (DOA) will be
replaced, based on availability, within 24 to 48 hours anywhere
in the U.S. Please call Customer Service at 800-214-0222 for
information.
5.2 Return/Repair Service
The LBS-1616 System contains no user serviceable
components. If you have a problem with your unit, please contact
the Customer Service Department. To facilitate our return/repair
processing please contact Broadata Communications, Inc. to
obtain a Return Material Authorization (RMA). Please include
the following information:
• Product model number
• Serial Number
• Complete description of problem
• Hardware installation description
Broadata Communications, Inc.
2545 West 237th Street, Suite K
Torrance, CA 90505
1-800-214-0222
(310) 530-1416
(310) 530-5958 (Facsimile)
e-mail: [email protected]
Website: www.broadatacom.com

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
Broadata Technical Support, (800) 214-0222
18
6.0 LIMITED WARRANTY
Broadata Communications, Inc. (BCI) warrants, for a period of one year
from date of shipment, each product sold shall be free from defects in
material and workmanship. BCI will correct, either by repair, or at BCI’s
election, by replacement, any said products that in our sole discretion
prove to be defective and are returned to the manufacturing location
within 30 days after such defect is ascertained. All warranties are limited
to defects arising under normal use and do not include malfunctions or
failure resulting from misuse, abuse, neglect, alterations, electrical power
problems, usage not in accordance with product instructions, improper
installation, or damage determined by BCI to have been caused by the
Buyer or repair made by a third party. Limited warranties granted on
products are to the initial customer end-user and are not transferable.
OUR LIABILITY UNDER THIS WARRANTY SHALL IN ANY CASE BE
LIMITED TO THE INVOICE VALUE OF THE PRODUCT SOLD AND BCI
SHALL NOT BE LIABLE TO ANYONE FOR CONSEQUENTIAL OR
INCIDENTAL DAMAGES ARISING FROM THE USE OF ITS PRODUCTS
OR THE SALE THEREOF. We make NO WARRANTY AS TO THE
MERCHANTABILITY OF ANY GOODS, OR THAT THEY ARE FIT FOR
ANY PARTICULAR PURPOSE OR END APPLICATION NOR DO WE
MAKE ANY WARRANTY, EXPRESSED OR IMPLIED OTHER THAN
AS STATED ABOVE.

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
7.0 APPENDIX A

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
Broadata Technical Support, (800) 214-0222
20

BCI LBS-16x16 User’s Manual
Link BridgeTM Universal 16x16 Optical/DVI/HDMI Matrix Switch
8.0 APPENDIX B
The following provides currently available LBS I/O cards and their
description. Their panel drawings are also shown.
LBS-8IN-OPT 8-Input Card, Optical (Video Only)
LBS-8IN-OPT-VP 8-Input Card, Optical (AD Compatibility)
LBS-8IN-OPT-ILCE 8-Input/ Card, Optical with Ethernet In-Line Control (AD Compatibility)
LBS-8-OUT-OPT 8-Output Card, Optical (Video Only)
LBS-8-OUT-OPT-VP 8-Output Card, Optical (AD Compatibility)
LBS-8-OUT-OPT-ILCE 8-Output Card, Optical with Ethernet In-Line Control (AD Compatibility)
Optical Input Port
Optical Input Port
Optical Input
Port
Optical Output Port
Optical Output Port
Optical Output Port
Ethernet for ILC
Ethernet for ILC
This manual suits for next models
1
Table of contents
Other Broadata Matrix Switcher manuals
Popular Matrix Switcher manuals by other brands

Keithley
Keithley 7072-HV instruction manual

Hall Research Technologies
Hall Research Technologies HSM-44-BX user manual

WolfPack
WolfPack HDTVFIX1616-HDR user manual

AMX
AMX AVS-OP-2004-347 Product View

Matrix Switch Corporation
Matrix Switch Corporation MSC-XV1616S product manual

Kramer
Kramer VS-3232DN-EM user manual