Silence Sentinel Basic G2 Installation and Operation Manual
OPERATION
Operational Guidelines
Operation
Front Panel LED indicators
“PWR/HB” LED: Blinks to indicate operation when power is applied. (Green)
“Reset” LED: Lit the Reset/Disable input is active. (Red)
“ACT” Left/Right LEDs: Lit when input audio is above threshold. (Yellow)
“Alarm” Left/Right Tally LEDs: Lit = Indicates a current or past silence alarm.
(Red)
“K1” Left “K2” Right LEDs: Lit = Lit when a relay is closed/active. (Green)
Front Panel Controls
Recessed Reset/Disable switch (“Reset”): Used to clear Alarm Tally LEDs after an
alarm or to disable alarms.
Stereo Mode Operation
When the Silence Sentinel® Basic G2 is “Enabled”, it will trigger in the absence of
audio (see trip level setup) on either or both channels after the delay time has expired
(See delay dipswitch SW2-1 through 4 and SW2-9) which will cause the following
action:
1 - The front panel left and/or right “ACT” audio LEDs extinguish.
2 - The left and/or right alarm tally “Alarm” LEDs and relay K1 activate.
3 – K2 relay pulses for either 2 or 20 seconds.
Note: The K2 relay will generate a pulse duration determined by JPR1.
When both channels return and the restore time delay has expired (if enable), the fol-
lowing action occurs:
1 – Relay K1 opens.
2 - The front panel left and right “ACT” audio LEDs will illuminate
3 - Either or both “Alarm” tally LED indicators will stay illuminated to provide his-
tory of the alarm until reset. To reset/clear an alarm, press in the disable (alarm
reset) switch and then press again to release the switch, or momentary pull the
remote “disable” input to ground.
Dual Monaural (Independent) Mode Operation
When the Silence Sentinel® Basic G2 is enabled, it will trigger in the absence of
audio (see trip level setup) on each of the independent channels after the delay time
has expired (See delay dipswitch SW2-1 through 4 and SW2-9).
The Silence Sentinel® Basic G2 when triggered will cause the following action:
1 - The left and or right “Alarm” tally LED(s) will illuminate.
2 – Relay K1 will close for the “Left” input and relay K2 will close for the “Right input.
When either audio channel returns, and the restore time delay has expired (if
enabled), the following action occurs:
1 - Either or both relays K1 and K2 will open.
2 - The “Alarm” tally LED indicators stay illuminated to provide history of the alarm.
To reset/clear an alarm, press in the disable (alarm reset) switch and then press again
to release the switch, or momentary pull the remote “disable” input to ground.