1
Specification
Model no.
BR10D
Power supply
220~240V, 50Hz
Humidity Removal capacity
9 L/day RT 30 oC , RH 80%
10 L/day RT 35 oC , RH 90%
Power consumption
TURBO (high) -730W
Electric heating element-650W
Air volume (max.)
185 m3/h
Fan (Ventilation) Speed
3
Water tank volume
5L
Working temperature range
1 ~ 32oC
Timer
1 ~ 24 hours
Continuous Drainage
Yes
Safety Device
Tip-over switch
Size (WxDxH)
340 x 232 x 511 mm
N.W.
7.5 Kg
Above is measured under RT 30 oC , RH 80%.
The data marked with * may vary for technical reasons. For greater precision,
please refer to the rating label placed on the product.
Current & Fuse : F2L250V or T2L250V
Disposal
This product should be taken to our local recycling centre for safety
treatment. Waste electrical and electronic products must not be
disposed of with household waste.

2
Where to position
Excess moisture will travel
throughout your home,
For this reason, the
dehumidifier should be
positioned, so that it can
draw this moist air
towards it from all over
the home.
When positioning the
dehumidifier, ensure that
it is placed on a level
surface and that there is a
minimum of 20 cm (8") of
space on either side of
the unit to allow for
efficient airflow.
Heater advice for Dryer
function. The distance
between air vent &
clothes must be kept at
least 40cm to avoid water
drop into machine and
cause damage.
Suitable to use in basement, kitchen, living room etc

3
Before use
Caution!
Operate this unit on a firm, flat surface to avoid water leak.
Ensure that it is kept upright at all times (including transport
and store).
Suggest to run the unit continuously for 24hrs on its first use.
Do not place on soft surfaces.
Ensure that there is at least 300mm between the sides of the
appliance and any flammable materials.
Ensure that there is at least 900mm from the top of the
appliance and any flammable materials.
The unit contains a chemical substance. The unit will emit a
chemical smell during the 1st hour of operation without any
dangerous consequences.
The unit features an anti-tip safety device that will switch the
unit off if it was tipped during operating.
Only connect the unit to a properly installed and easily
accessible socket so that you can quickly pull the plug in an
emergency.
DO NOT OBSTRUCT THE AIR INTAKES AND EXHAUSTS.
FOR INDOOR USE ONLY.
NOT FOR COMMERCIAL AND INDUSTRIAL USE.
DO NOT EXPOSE THE UNIT TO DIRECT SUNLIGHT.
DO NOT USE IN CABINET, CLOSET, BOATS, CARAVANS OR
SIMILAR LOCATIONS.
DO NOT USE THE UNIT IN BATHROOMS, SWIMMING POOLS,
WASHROOMS OR SIMILAR WET AREAS.
DO NOT USE THE UNIT CLOSE TO A BATHTUB, SHOWER,
SINK AND THE LIKE.
Do not use the appliance in locations where paint, petrol or

4
other flammable liquids are used or stored.
Do not allow the appliance to fall over when there is water in
the bucket.
AVOID THE UNIT FROM SPLASH. DO NOT LET ANY LIQUID
ENTER THE UNIT.
DO NOT PLACE A CONTAINER WITH LIQUID ON TOP OF THE
UNIT.
THE CONDENSED WATER IS NOT FOR DRINKING EITHER
FOR HUMAN OR ANIMALS.
DO NOT USE BUG SPRAYS OR OTHER FLAMMABLE
CLEANSERS ON THE UNIT.
Do not lay the cord under carpets/rugs so that you can
regularly check its condition.
DO NOT TOUCH THE PLUG OF THE UNIT WITH WET HANDS.
Never use the cord of the unit as a carrying strap.
Before moving the unit, first switch off, then unplug and empty
the water tank. Basically, it takes around 2 minutes to stop
the unit and this allows the heater to cool down.
Always unplug the unit from the mains and wait for at least
one hour before carrying out any maintenance, transport or
cleaning of the unit.
Always switch the unit off and pull the plug out of the socket:
If you are not using the unit.
Before you clean the unit.
Before you assemble the accessories.
If a fault occurs.
In the event of a storm.
AVOID OVER-TWISTING, -COILING, -PULLING THE POWER
CORD, NEVER USE NYLON OR IRON WIRE TO TIDE THE
POWER CORD.

5
DO NOT USE EXTENSION CORDS.
IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED
BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PERSON, TO
AVOID HAZARD.
THE MAINS SUPPLY MUST CONFORM TO THE
SPECIFICATION SHOWN ON THE RATING PLATE AT THE
BACK OF THE UNIT.
THE APPLIANCE SHALL BE INSTALLED IN ACCORDANCE
WITH NATIONAL WIRING REGULATIONS.
NEVER REACH TO RETRIEVE THE UNIT IF IT HAS FALLEN IN
WATER. IN SUCH CASE, IMMEDIATELY PULL THE PLUG.
HAVE THE UNIT CHECKED BEFORE USING IT AGAIN.
This appliance can be used by children aged from 8 ye
ars and above and persons with reduced physical, sensory
or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
Appliances intended for indoor use (excluding laundry room).
While using DRYER mode for clothes, please keep the unit AT
LEAST 40CM away from the objects (ex. the clothes) and
ensure no water will drip into the air vent of unit.
SUGGEST TO SEND THE UNIT FOR PROFESSIONAL
MAINTENANCE PERIODICALLY.
ONLY A LICENSED PROFESSIONAL IS ALLOWED TO
DISMANTLE OR MODIFY THE APPLIANCE.
THE MACHINE IS TO BE USED ONLY FOR ITS PRESCRIBED PURPOSE.
ANY OTHER USE IS DEEMED TO BE A CASE OF MISUSE. THE

6
USER/OPERATOR, NOT THE MANUFACTUER WILL BE LIABLE FOR
ANY DAMAGE OR INJURIES OF ANY KIND CAUSED AS A RESULT OF
THIS.
DO NOT USE YOUR DESICCANT UNDER THE FOLLOWING

7
Parts

8
Programming Feature
1. FAN SPEED Indicator (Sleep,
NORM, TURBO)
2. Humidity/Timer Display Window
3. TIMER Indicator
4. AUTO button
5. AIR CLEAN Indicator
6. FAN SPEED Button
7. DRYER Indicator
8. DRY(TURBO) Button
9. Humidity Button
10. ON indicator (heat element
operation indicator)
11. Power (ON/OFF) Button
12. “Full Water” indicator
13. TIMER button
14. AIR CLEAN Button

9
FAN SPEED BUTTON 3 selections:
SLEEP (MUTE): Low fan speed with Low heat and the unit is quieter. If the
ambient humidity is less than set humidity, it will run at low fan (ventilation)
only, no heat. Note! In sleep mode, the humidity indicator in the front plate
will not light on.
NORM (standard): MEDIUM fan speed with HIGH heat setting. If the ambient
humidity is below set humidity, the unit will run at Medium fan speed only, no
heat.
TURBO: HIGH fan with HIGH Heat setting. If the ambient humidity is below
set humidity, the unit will run at HIGH fan speed only, no heat.
Indicator for the set mode will light on.
AUTO BUTTON
By pressing this button, the unit will work automatically as below:
Above 70% ….in TURBO mode.
Between 55% and 70% …. in SLEEP model.
Less than 55%, …. unit stops for 30 minutes before rechecking room humidity.
Will not restart until humidity is above 55%.
DRY (LAUNDRY) BUTTON (40% RH / high fan speed/high heat)
Suitable for drying clothes.
Set desired humidity at 40%, unit will work 8hrs continuously.
Rest for 30 minutes
If room humidity > 40%, unit work for another 8hrs.
If room humidity <40%, unit rests for another 30 minutes
The DRYER indicator will be light on
☆Under this mode, the fan speed is always fixed at HIGH speed, not adjustable.
HUMIDITY BUTTON
CO (continuous dehumidify) , 40%, 50%, 60% or 70% The set HUMIDIFY level will
show on the LED display .
Please Note:
1. After 8hrs of the heater running continuously, the unit will rest for 30 minutes
before resuming the previously selected operation.
2. If the HUMIDITY button is not set, the unit will work at the default setting:
50% RH /low fan speed/low heat.

10
※Continuous dehumidify mode
For safety reason, the machine will stop automatically after running for 8hrs.
After rest for 30 minutes, resumes to work. Repeat in this cycle.
※Continuous dehumidify mode + Ambient humidity less than 35%
the heater works for 15minutes -> rest for a few minutes, repeats in this cycle,
unless the humidity rises up.
※Ambient temperature higher than 36oC
the heater stops , the fan keeps running to check humidity (last set mode) /
temperature, then follows the general logic of stopping for 30 minutes if humidity is
reached.
※Working with humidity setting: 40%, 50%, 60% or 70%
the machine will stop automatically after running for 8hours, no matter the setting
humidity is reached or not. After rest for 30minutes, resumes to work. Repeat in
this cycle.
POWER BUTTON Press this button to start or turn off the machine. Please note it
may take a few minutes for the unit to turn off once pressed.
TIMER BUTTON
1. Press TIMER button to set the working hours you need.
- the LED display will show the hour you set (starting from 0, 1 to 24 in a cycle).
- The TIMER Indicator will light on at the same time.
When the set time has been reached, the machine will turn off automatically.
2. By pressing TIMER but without turning on other functions, you can PRE-SET
time to work. For example, if you press the timer to '2', the unit will turn on
automatically 2 hours after and works in the previous mode.

11
AIR CLEAN BUTTON This mode runs the fan without dehumidifying the air.
Suitable for purifying the air when the set-up humidity has been reached
(especially when the optional HEPA filter is installed).
AIR CLEAN indicator will light on at the same time. The fan speed is adjustable in
this mode.
Please Note: If using a HEPA filter while dehumidifying, the performance of the unit may be
reduced by 10%.
DISPLAY WINDOW
Displays the room temperature (0 ~ 50oC )
Displays the room humidity (35~95%RH).
Displays the set humidity, while pressing the HUMIDITY button.
Displays the set time while pressing the TIMER, after 8 seconds, return to room
humidity.
ON INDICATOR (heat operation indicator)
lights on in GREEN as the heat element is working.
lights on in RED and blink as the unit is tipped over.
WATER FULL INDICATOR It turns to RED and blink when the water tank is full or the tank is
not in proper position.
HUMIDITY INDICATOR IN THE FRONT
This unit is equipped with an intelligent humidity display on
the front, giving the user an immediate visual indication of
the ambient humidity. The front LED’s will change color to
indicate the current humidity level.
☆In SLEEP mode, this indicator will not work.
Blue light – room humidity > 70%
Green light – room humidity 50~70%
Red light –room humidity < 50%

12
Operation
1. Plug the unit into a correct mains socket. (Please refer to the rating label at the
rear of the unit.)
2. OPEN THE AIR DEFLECTOR at the top.
3. Press button POWER to turn on the unit. The unit will start to work in LOW
FAN/LOW HEAT/LOW DEHUMIDIFY (humidity setting: 50%)
4. Press button HUMIDITY to set the room humidity you need: continuous
de-humidifying , 40%, 50%, 60% or 70% (the set level will appear on the LED
display)
5. Press button FAN SPEED to choose the ventilation speed, MUTE, NORM
(normal/standard) or TURBO.
6. Press button TIMER to set the working hour you need (1~24 hours).
7. To turn off the unit, press button POWER again.
☆You may set the unit in AUTO mode or DRY mode, please refer to the
description in the previous page.
IMPORTANT!
1. After switching off the unit, it takes at least 2 minutes to OFF the unit
completely, this allows the heater to cool down. DO NOT DISCONNECT THE
PLUG DIRECTLY FOR QUICK-OFF.
2. Do not operate the unit without the AIR FILTER.

13
3. While using DRYER mode for clothes, please keep the air vent (air outlet) of the unit
AT LEAST 40CM away from the objects (ex. the clothes) and ensure no water will drip
into the air vent of unit. ☆ATTENTION! DO NOT used in the closet, wardrobe .
4. Tip Over
protection This
unit is equipped with tilt switch for overheat protection. While the unit is tipped ,
the unit will stop automatically. The ON indicator will turn into RED and blink for
warning, also the display window will show E5. After repositioning the unit upright,
press POWER button to re-start.
5. Self-Diagnosis: This machine is equipped with self-diagnosis function. If something
is wrong in the machine, the LED will show the signal from E1 to E7 (each represents
different situation).
E5 means the unit is tipped over. Please re-posit the unit upright, press POWER
button to re-start.
For the other signal, please call your service centre. DO NOT dismantle the machine
by yourselves in any case.

14
Drainage
While the water tank is full, the unit will stop working for self-protection. The water full
indicator will blink in red and the unit will buzz for warning.
To empty the tank, please follow the steps:
1. Hold the unit with one hand to make it stand firmly.
2. Pull out the tank squarely from the unit.
3. Grasp the water tank handle, remove the cover of the tank, empty the water from the
drain.
4. After the tank was empty, return the water tank to its position, make sure it is
properly positioned, so the 'water full' sign can go out and your dehumidifier is
operating again.
Please note, if the water tank has not been positioned well, the water full indicator will
turn into red and the unit will keep buzzing.

15
CONTINUOUS DRAINAGE
When the dehumidifier is operated in very high humidity, the water tank will require more
frequent drainage. In this condition, it may be more convenient to set the unit up for
continuous drainage with the following procedures:
1. Connect the drain hole with a water tube of inner diameter 11mm. ☆Please note,
the water tube is not supplied with the unit.
2. Ensure the water will always drain away freely and the tube will remain in right place.
Note! In very cold weather conditions, precautions should be taken to prevent the
water tube from freeing.
3. When you don’t need it, please remove the water tube, then the water will go again
to the water tank.
Maintenance
Always unplug the unit from the mains and wait for at least one hour before carrying out
any maintenance or cleaning of the unit.
CLEANING THE BODY
Use soft cloth to wipe the unit clean.
Don't ever use volatile chemicals, gasoline, detergents, chemically treated clothes, or other
cleansing solutions. These all could possibly hurt the cabinet.

16
CLEANING THE FILTER
Draw out the air filter from the rear of the unit.
For dust filter (washable filter) –
1. Use a vacuum cleaner or tap the filter lightly
for easy cleaning. If the filter is particularly
dirty, use warm water with a small amount
of medium strength.
2. Make sure the filter is completely dry
before replacing.
3. Do not expose the filter to sunlight.
For active carbon filter –
This filter is not washable. Its life span is variable and depends on the ambient conditions
where the appliance is used. The filter should be checked periodically (about every 6
months) and replaced if necessary.
STORAGE
If not use the unit for an extended period of time. Please:
Turing the unit off, unplug and tidy AC cord.
Completely empty the water tank and wipe it clean.
Cover the unit and store where it will not receive direct sunlight.

17
Trouble shooting
PROBLEM
POSSIBLE REASON
The unit doesn’t work at all.
1. Bad connection of the main plug
2. Water tank not positioned well or full.
3. Is the unit standing upright and level.
The unit not work dehumidifying
1. Too heavy dust on air filter.
2. Any things stuck on intake or air vent.
3. Too low room humidity already.
Dehumidifying efficiency not good
1. Too many doors and windows open.
2. Any room equipment increases the room
humidity.
Abnormal noises from the motor
1. Check and clean the air filter
2. Is the unit standing upright and on a level
surface?
The unit leaks water
1. Has the unit been tipped?
2. Check if the float of the water tank is
blocked by foreign material.
After the unit has been switched off,
the fan motor is still running
1. After the unit stops, about 2 minutes are
needed to cool down the electric heater by
running the internal fan.
Please TURN off immediately the power when the unit emits strange noises, odors, etc.
180704
This manual suits for next models
1
Table of contents
Other BROLIN Dehumidifier manuals
Popular Dehumidifier manuals by other brands

Seaira Global
Seaira Global WatchDog 900c Installation and operation manual

MCS Master
MCS Master DH 752 User and Maintenance Book

Midea
Midea MDDF-16 Owner's manual & installation manual

Aprilaire
Aprilaire 1700 Safety and installation instructions

Sharp
Sharp DW-RN23A-W Operation manual

Master
Master DH 752 User and Maintenance Book