Quality Construction Features
A. Heavy steel boiler frame, built and stamped in accordance
with the ASME Boiler Code, Section IV.
B. Large volume water leg downcomers promote rapid internal
circulation, temperature equalization and efficient heat transfer.
C. Bryan bent water tubes are flexible, individually replaceable with-
out welding or rolling. Never more than two tube configurations.
D. Boiler tube and furnace area access panel: heavy gauge
steel casing with 2" high temperature ceramic fiber and insulation,
bolted and tightly sealed to boiler frame.
E. Jacket access panels make the interior of the boiler easily
accessible for service and inspection.
F. Steel boiler jacket with 16 gauge rust-resistant zinc coating
and attractive enamel finish, insulated with 1½" fiberglass to insure
exceptionally cool outer surface.
G. Minimum sized flue vent.
H. Forced draft, flame retention head type burner. Efficient
combustion and quiet operation.
I. All controls, gauges, relief valve(s) are factory installed and
wired and easily accessible for servicing.
J. Electrical box: all controls installed and connected to terminal
strip.
K. Water side interior accessible for cleanout and inspection,
front and rear openings, upper and lower drums.
L. Steel plate boiler base with lightweight, high temperature
insulating firebrick combustion chamber, designed for maximum
combustion efficiency.
Form No. 6700
(Rev. 5/07)
Guaranteed 85%
efficiency
• With HE-CLM Series Boilers,
you get a guaranteed 85%
combustion efficiency result-
ing from a uniquely designed
integrated extended surface
heat extractor.
• What's more, HE-CLM Boilers
offer high operating
efficiency—at all normal
operation temperatures—
without the complications
of condensation concerns.
Bryan HE-CLM Series Boiler Specifications
Bryan “Flexible Water Tube”
HE-CLM Series Water Boilers
900,000 to 3,000,000 BTUH
Forced draft gas fired
Originators of the “Flexible Water Tube” design
Model HE-CLM300-W-FDG
BOILER INPUT OUTPUT @ 85% EFFICIENCY(1) HTG.SURFACE APPROX. SHIP
MODEL MBH (KW) MBH (KW) HP (KW) SQ.FT.(M2) LBS. (KG)
HE-CLM90 900 (264) 765 (224) 23 (224) 171 (15.9) 2,110 (957)
HE-CLM120 1,200 (352) 1,020 (299) 30 (299) 227 (21.1) 2,400 (1,089)
HE-CLM150 1,500 (440) 1,275 (374) 38 (374) 282 (26.2) 2,860 (1,297)
HE-CLM180 1,800 (527) 1,530 (448) 46 (448) 338 (31.4) 3,200 (1,452)
HE-CLM210 2,100 (615) 1,785 (523) 53 (523) 394 (36.6) 3,740 (1,697)
HE-CLM240 2,400 (703) 2,040 (598) 61 (598) 451 (41.9) 4,200 (1,905)
HE-CLM270 2,700 (791) 2,295 (672) 69 (672) 506 (47.0) 4,740 (2,150)
HE-CLM300 3,000 (879) 2,550 (747) 76 (747) 564 (52.4) 5,175 (2,348)
NOTES : (1) Output and horsepower based on an average natural gas combustion efficiency of 85%.
BRYAN®BOILERS
Bryan HE-CLM Series Gas Fired Flexible Tube Boilers
Form No. 6700 ©2007 Bryan Steam LLC Printed in USA
57-8782
Efficient Water Tube Design
The Bryan Flexible Water Tube provides for extremely fast
internal circulation for maximum heat transfer and operating
efficiency.
No “Thermal Shock”
The flexibility of the bent water tube design eliminates all
possible damage from “Thermal Shock” and from stresses
caused by poor or unequal internal circulation. This is particu-
larly important with forced hot water heating systems designed
for higher temperatures and greater temperature drops.
Natural Internal Circulation
The water tube design and the large water leg downcomers
provide adequate internal circulation without concern over ex-
terior pumping conditions. Low pressure drop through boiler.
Compact — Minimum Floor Space
Requires less floor space than most boilers — minimum
boiler room size.
Shipped completely assembled and wired.
Tubes are easily removable and replaceable, requiring little
service space.
Combination thermometer and pres-
sure gauge, ASME-rated boiler relief
valve, water temperature control (240°F
max. std.), high limit control, probe
LWCO. Electronic combustion safety
control, automatic operating gas valve,
safety gas valve, pilot solenoid valve,
pilot ignition assembly, main manual
gas shut-off valve, pilot cock, pilot
and main gas pressure regulators, air
safety switch, control panel, all controls
installed and wired.
Dimensions and specifications are subject to change without notice. Consult factory for certified dimensions.
Bryan Steam LLC —Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone: 765-473-6651
•
Internet:www.bryanboilers.com
Fax: 765-473-3074
•
E-mail: [email protected]
OPTIONAL CONSTRUCTION:
Optional construction to ASME Power
Boiler Code requirements for tempera-
tures exceeding 240°F and/or pres-
sure exceeding 160 psi to maximum
of 285°F operating and 300°F design
temperature and 250 psi.
When ordering, please specify:
1. Boiler size
2. Supply and return
temperatures required
3. Boiler relief valve setting
4. Type of fuel: natural, LP,
or other gas
5. Gas BTU content, specific
gravity and pressure
available
6. Electric power voltage,
phase and frequency
7. Optional extra equipment
or construction
8. Special approvals required
(UL, CUL, CSD-1, FM, or IRI)
9. Altitude
OPTIONAL EQUIPMENT:
1. Manual reset high limit control
2. Manual reset low water cutoff
3. Auxiliary low water cutoff
4. Combination low water cutoff
and feeder
5. Alarm bells or horns
6.
UL, CUL, CSD-1, FM, IRI
or other in-
surance approved control systems
7. Control panel mounted on boiler
8. Indicating lights, as desired
9. Lead-lag systems for two or more
boilers with or without outdoor
reset control
STANDARD EQUIPMENT:
Bryan HE-CLM Series Boilers Standard and Optional Equipment
10. Draft control system
11. Special construction
and knocked down
NOTE: * Gas train and control location dimensions will vary depending on job specifications and conditions.
BOILER DIMENSIONS in inches (cm)
A B C D E* F G H I J K L
BOILER Length Width Height Overall Gas Train Supply Return Flue Flue Min. Tube Clearance for Floor to
MODEL Of Outside Over Length Connection Nozzle Nozzle Size Location Removal Servicing Flow
NUMBER Jacket Jacket Jacket Clearance Burner Nozzle
HE-CLM90-W 41
7/16 34 5/8 72 1/16 69
7/16 1 NPT 3 NPT 3 NPT 10 20 11/16 30 36 76 3/16
(105.24) (87.94) (180.03) (176.98) (2.54) (7.62) (7.62) (25.40) (52.54) (76.2) (91.44) (193.51)
HE-CLM120-W 50
11/16 34 5/8 72 1/16 78
11/16 1
1/4 NPT 3 NPT 3 NPT 10 25 5/16 30 36 76 3/16
(128.74) (87.94) (180.03) (199.86) (3.18) (7.62) (7.62) (25.40) (64.29) (76.2) (91.44) (193.51)
HE-CLM150-W 59
11/16 34 5/8 72 1/16 87
11/16 1
1/2 NPT 3 NPT 3 NPT 12 29 13/16 30 36 76 3/16
(151.60) (87.94) (180.03) (212.72) (3.81) (7.62) (7.62) (30.48) (75.72) (76.2) (91.44) (193.51)
HE-CLM180-W 69
1/8 34 5/8 72 1/16 97
1/82NPT 3 NPT 3 NPT 14 34 9/16 30 36 76 3/16
(175.57) (87.94) (180.03) (246.69) (5.08) (7.62) (7.62) (35.56) (87.78) (76.2) (91.44) (193.51)
HE-CLM210-W 78
3/8 34 5/8 72 1/16 106
3/82 NPT 3 NPT 3 NPT 14 39 3/16 30 36 76 3/16
(199.07) (87.94) (180.03) (270.19) (5.08) (7.62) (7.62) (35.56) (99.53) (76.2) (91.44) (193.51)
HE-CLM240-W 88 34 5/8 72 1/16 116 2 NPT 3 NPT 3 NPT 16 44 30 36 76 3/16
(223.52) (87.94) (180.03) (294.64) (5.08) (7.62) (7.62) (40.64) (111.76) (76.2) (91.44) (193.51)
HE-CLM270-W 97 34 5/8 72 1/16 125 2 NPT 3 NPT 3 NPT 16 481/2 30 36 76 3/16
(246.38) (87.94) (180.03) (317.50) (5.08) (7.62) (7.62) (40.64) (123.19) (76.2) (91.44) (193.51)
HE-CLM300-W 106
5/8 34 5/8 72 1/16 134
5/82
1/2 NPT 3 NPT 3 NPT 16 53 3/16 30 36 76 3/16
(270.82) (87.94) (180.03) (341.91) (6.35) (7.62) (7.62) (40.64) (40.64) (76.2) (91.44) (193.51)

This manual suits for next models

17

Other Bryan Boilers Boiler manuals

Bryan Boilers BE-210-W4T7 User manual

Bryan Boilers

Bryan Boilers BE-210-W4T7 User manual

Bryan Boilers BFIT 400 User manual

Bryan Boilers

Bryan Boilers BFIT 400 User manual

Bryan Boilers BH Series User manual

Bryan Boilers

Bryan Boilers BH Series User manual

Bryan Boilers Knockdown RV-500 User manual

Bryan Boilers

Bryan Boilers Knockdown RV-500 User manual

Bryan Boilers RV Series User manual

Bryan Boilers

Bryan Boilers RV Series User manual

Bryan Boilers Water Boiler User manual

Bryan Boilers

Bryan Boilers Water Boiler User manual

Bryan Boilers DR250 User manual

Bryan Boilers

Bryan Boilers DR250 User manual

Bryan Boilers Flexible Water Tube Boilers User manual

Bryan Boilers

Bryan Boilers Flexible Water Tube Boilers User manual

Bryan Boilers Concert Manual

Bryan Boilers

Bryan Boilers Concert Manual

Bryan Boilers Knockdown K-450 User manual

Bryan Boilers

Bryan Boilers Knockdown K-450 User manual

Bryan Boilers D Series Manual

Bryan Boilers

Bryan Boilers D Series Manual

Bryan Boilers FREE FLEX User manual

Bryan Boilers

Bryan Boilers FREE FLEX User manual

Bryan Boilers CLM Setup guide

Bryan Boilers

Bryan Boilers CLM Setup guide

Bryan Boilers BE Series User guide

Bryan Boilers

Bryan Boilers BE Series User guide

Bryan Boilers A-H-FS-15-12-50-D operati Service manual

Bryan Boilers

Bryan Boilers A-H-FS-15-12-50-D operati Service manual

Bryan Boilers Broile System User manual

Bryan Boilers

Bryan Boilers Broile System User manual

Bryan Boilers CLM User manual

Bryan Boilers

Bryan Boilers CLM User manual

Bryan Boilers EB-200-W-FDGO User manual

Bryan Boilers

Bryan Boilers EB-200-W-FDGO User manual

Bryan Boilers K Series User manual

Bryan Boilers

Bryan Boilers K Series User manual

Bryan Boilers Electric Water Boilers Manual

Bryan Boilers

Bryan Boilers Electric Water Boilers Manual

Bryan Boilers CLM-150-S150-GI User manual

Bryan Boilers

Bryan Boilers CLM-150-S150-GI User manual

Bryan Boilers Bryan DR Series User manual

Bryan Boilers

Bryan Boilers Bryan DR Series User manual

Bryan Boilers AB Series User manual

Bryan Boilers

Bryan Boilers AB Series User manual

Bryan Boilers CLM User manual

Bryan Boilers

Bryan Boilers CLM User manual

Popular Boiler manuals by other brands

Benchmark VOKERA Mynute 12 VHE instructions

Benchmark

Benchmark VOKERA Mynute 12 VHE instructions

DOMUSA TEKNIK SANIT 300 Installation and operating instructions

DOMUSA TEKNIK

DOMUSA TEKNIK SANIT 300 Installation and operating instructions

Bosch C950ES installation manual

Bosch

Bosch C950ES installation manual

SYNC 1.0 Installation & operation manual

SYNC

SYNC 1.0 Installation & operation manual

Dunkirk DCBF-125 Installation, operation & maintenance manual

Dunkirk

Dunkirk DCBF-125 Installation, operation & maintenance manual

Windhager BIOWIN 2 TOUCH operating manual

Windhager

Windhager BIOWIN 2 TOUCH operating manual

E.C.A. Proteus Plus Installatio and user's operating instructions

E.C.A.

E.C.A. Proteus Plus Installatio and user's operating instructions

Immergas MINI EOLO 28 3E Instructions and warnings

Immergas

Immergas MINI EOLO 28 3E Instructions and warnings

Elgena KB 6 Installation and instructions for use

Elgena

Elgena KB 6 Installation and instructions for use

Econoburn EBW SERIES Operator's manual

Econoburn

Econoburn EBW SERIES Operator's manual

Truma BG 10 installation instructions

Truma

Truma BG 10 installation instructions

Crown Boiler BWF095 installation instructions

Crown Boiler

Crown Boiler BWF095 installation instructions

Ariterm Biomatic 20 Installation, operation and maintenance

Ariterm

Ariterm Biomatic 20 Installation, operation and maintenance

Biasi Riva Plus HE M296.24SM/C Service manual

Biasi

Biasi Riva Plus HE M296.24SM/C Service manual

Raypak RAYTHERM H-0042 specification

Raypak

Raypak RAYTHERM H-0042 specification

Viessmann VITOCELL 100-B Installation instructions for contractors

Viessmann

Viessmann VITOCELL 100-B Installation instructions for contractors

Viessmann WB1A Series Installation and service instructions

Viessmann

Viessmann WB1A Series Installation and service instructions

Kostrzewa Mini Matic user manual

Kostrzewa

Kostrzewa Mini Matic user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.