1
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
iPLASMA INSTALLATION GUIDE
PRODUCT FEATURES:
LED luminaire ideal for lighting facades, large structures, bridges, sports areas,
retail spaces and perimeter areas.
iPlasma provides a high-intensity wash of light with customisable beam angles for
floodlighting, spotlighting, wall washing and grazing. Three sizes: small, medium and large.
Advanced thermal design with cutting-edge manufacturing process and materials.
Designed to last in extremely harsh environments.
RECOMMENDATIONS FOR THE USER:
1)Before the installation, make sure that there is no voltage.
2)Do not touch the fitting when it is working on / switched on
3)Do not look at the fitting directly or from a short distance.
4)Disconnect / switch off the fitting before changing the lamps
NOTES:
-Technical amendments are reserved.
-CE – Conformity mark
-The manufacturer is then discharged from liability when damage is caused by improper
use or installation.
-Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use
high pressure cleaners.
2
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
iPLASMA INSTALLATION GUIDE
Mounting Surface
1) Drill holes on the mounting surface and install the fixing plugs.
The luminaire is screwed onto the mounting surface.
2) Allen imbus bolt on the luminaire foot are loosened to the desired angle and the tightened again.
Mounting Holes
Mounting Surface
Mounting Surface
Mounting Surface
Allen
Inbus
Bolt
3
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
- iPlasma Mono Electrical Connection
IP 68 Terminal
Block
*Page 4
IP 68 Plug
Connector
*Page 5
or or
IP 68 Socket
When connecting the
luminaires, make sure that the
same color cables are
matching. (+) Brown
( ) Yellow - Green
(-) Blue
- iPlasma Mono Multi Electrical Connection
The incoming
power line.
- iPlasma RGB-RGBW Electrical Connection
220VAC
When connecting the
luminaires, make sure that the
same color cables are
matching.
*Please contact us for cables if in different colors.
When connecting the
luminaires, make sure that
the same color cables are
matching.
*Please contact us for cables if in different colors.
DATA
(+) White
( ) Green
(-) Brown
- iPlasma RGB-RGBW Multi Electrical Connection
*Install the luminaires according to the order in numbers. The cable from main controller should first be connected to the luminaire number 1.
(+) Brown
( ) Yellow - Green
(-) Blue
iPLASMA INSTALLATION GUIDE
The incoming
power line.
220VAC
OUT 220VAC
IN
Input Data
Input Electric
220VAC
DATA
Input
Electric
Input Data
220VAC
DATA
220VAC
DATA
220VAC
DATA
220VAC
DATA
IP 68 Terminal Block IP 68 Plug Connector IP 68 Socket
RESIN
At the outlet of AC output RESIN cable end of
the final luminaire, the component is tightened
as a filled material or protected by resin.
DMX Main
Controller
and
Fuse Box
220VAC
OUT
DATA
OUT
Max 5mt Cable Max 5mt
Cable
Max 22 Piece
220VAC
OUT 220VAC
IN 220VAC
OUT 220VAC
IN
22
220VAC
OUT IN DATA
OUT IN 2
220VAC
OUT IN DATA
OUT IN 1
220VAC
OUT IN DATA
OUT IN
4
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
iPLASMA INSTALLATION GUIDE
5
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
iPLASMA INSTALLATION GUIDE
6
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
Considerations
- Do not cut-off or damage the cables of the products supplied as sockets.
Otherwise, water may enter to the luminaire through cable and damage the electronic
parts inside.
- If you make the electrical connection, except for IP.68 Terminal Block - IP.68 Plug connector
- IP.68 socket; the connections must be under IP protection. Otherwise, water may enter to the
luminaire through cable and damage the electronic parts inside.
- The IP68 Connecting kits must be assembled in accordance with the installation instructions.
Otherwise, water may enter to the luminaire through cable and damage the electronic parts inside.
- The luminaire should not be opened and screws should not be loosened. If you want to open the
luminaire, please contact our company.
Out of Warranty Situations
- Opening the product or loosening the screws.
- Product last output cable is not protected IP67-IP68.
- Faulty electrical connection.
- Wrong IP68 socket-terminal block- plug connector connection.
(Wrong opening of the cable length, fauly tightening the screws etc.)
- If the IP68 Connecting kits are under water.
iPLASMA INSTALLATION GUIDE

Popular Lantern manuals by other brands

Saxby Lighting 75271 Instruction leaflet

Saxby Lighting

Saxby Lighting 75271 Instruction leaflet

BEGA 77 148 Instructions for use

BEGA

BEGA 77 148 Instructions for use

BEGA 99 326 Instructions for use

BEGA

BEGA 99 326 Instructions for use

Archon EX99-LED Installation, operating,  & maintenance instructions

Archon

Archon EX99-LED Installation, operating, & maintenance instructions

BEGA 3590 Instructions for use

BEGA

BEGA 3590 Instructions for use

AEL AVL SERIES installation instructions

AEL

AEL AVL SERIES installation instructions

Cooper Lighting VISTRAL installation instructions

Cooper Lighting

Cooper Lighting VISTRAL installation instructions

Chimera 1827 Instructions for care and use

Chimera

Chimera 1827 Instructions for care and use

Makita BML184 instruction manual

Makita

Makita BML184 instruction manual

LED Group RSUF486FT-24 manual

LED Group

LED Group RSUF486FT-24 manual

National Geographic 90-48500 operating instructions

National Geographic

National Geographic 90-48500 operating instructions

ubbink Multi Bright Float 3 LED manual

ubbink

ubbink Multi Bright Float 3 LED manual

KingShield ELTSLED65NM Installation & operating instructions

KingShield

KingShield ELTSLED65NM Installation & operating instructions

olympia electronics GR-938/15L quick start guide

olympia electronics

olympia electronics GR-938/15L quick start guide

DS Produkte 781976 instructions

DS Produkte

DS Produkte 781976 instructions

Philips Vari-lite VL3500 Wash FX Luminaries Service manual

Philips

Philips Vari-lite VL3500 Wash FX Luminaries Service manual

KILLARK KF1L SERIES Installation operation & maintenance

KILLARK

KILLARK KF1L SERIES Installation operation & maintenance

Midstream Titan Series Installation guidance

Midstream

Midstream Titan Series Installation guidance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.