iPLASMA INSTALLATION GUIDE
PRODUCT FEATURES:
LED luminaire ideal for lighting facades, large structures, bridges, sports areas,
retail spaces and perimeter areas.
iPlasma provides a high-intensity wash of light with customisable beam angles for
floodlighting, spotlighting, wall washing and grazing. Three sizes: small, medium and large.
Advanced thermal design with cutting-edge manufacturing process and materials.
Designed to last in extremely harsh environments.
RECOMMENDATIONS FOR THE USER:
1)Before the installation, make sure that there is no voltage.
2)Do not touch the fitting when it is working on / switched on
3)Do not look at the fitting directly or from a short distance.
4)Disconnect / switch off the fitting before changing the lamps
NOTES:
-Technical amendments are reserved.
-CE – Conformity mark
-The manufacturer is then discharged from liability when damage is caused by improper
use or installation.
-Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use
high pressure cleaners.
2
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
iPLASMA INSTALLATION GUIDE
Mounting Surface
1) Drill holes on the mounting surface and install the fixing plugs.
The luminaire is screwed onto the mounting surface.
2) Allen imbus bolt on the luminaire foot are loosened to the desired angle and the tightened again.
Mounting Holes
Mounting Surface
Mounting Surface
Mounting Surface
Allen
Inbus
Bolt
3
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
- iPlasma Mono Electrical Connection
IP 68 Terminal
Block
*Page 4
IP 68 Plug
Connector
*Page 5
or or
IP 68 Socket
When connecting the
luminaires, make sure that the
same color cables are
matching. (+) Brown
( ) Yellow - Green
(-) Blue
- iPlasma Mono Multi Electrical Connection
The incoming
power line.
- iPlasma RGB-RGBW Electrical Connection
220VAC
When connecting the
luminaires, make sure that the
same color cables are
matching.
*Please contact us for cables if in different colors.
When connecting the
luminaires, make sure that
the same color cables are
matching.
*Please contact us for cables if in different colors.
DATA
(+) White
( ) Green
(-) Brown
- iPlasma RGB-RGBW Multi Electrical Connection
*Install the luminaires according to the order in numbers. The cable from main controller should first be connected to the luminaire number 1.
(+) Brown
( ) Yellow - Green
(-) Blue
iPLASMA INSTALLATION GUIDE
The incoming
power line.
220VAC
OUT 220VAC
IN
Input Data
Input Electric
220VAC
DATA
Input
Electric
Input Data
220VAC
DATA
220VAC
DATA
220VAC
DATA
220VAC
DATA
IP 68 Terminal Block IP 68 Plug Connector IP 68 Socket
RESIN
At the outlet of AC output RESIN cable end of
the final luminaire, the component is tightened
as a filled material or protected by resin.
DMX Main
Controller
and
Fuse Box
220VAC
OUT
DATA
OUT
Max 5mt Cable Max 5mt
Cable
Max 22 Piece
220VAC
OUT 220VAC
IN 220VAC
OUT 220VAC
IN
22
220VAC
OUT IN DATA
OUT IN 2
220VAC
OUT IN DATA
OUT IN 1
220VAC
OUT IN DATA
OUT IN
4
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
iPLASMA INSTALLATION GUIDE
5
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
iPLASMA INSTALLATION GUIDE
6
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
Considerations
- Do not cut-off or damage the cables of the products supplied as sockets.
Otherwise, water may enter to the luminaire through cable and damage the electronic
parts inside.
- If you make the electrical connection, except for IP.68 Terminal Block - IP.68 Plug connector
- IP.68 socket; the connections must be under IP protection. Otherwise, water may enter to the
luminaire through cable and damage the electronic parts inside.
- The IP68 Connecting kits must be assembled in accordance with the installation instructions.
Otherwise, water may enter to the luminaire through cable and damage the electronic parts inside.
- The luminaire should not be opened and screws should not be loosened. If you want to open the
luminaire, please contact our company.
Out of Warranty Situations
- Opening the product or loosening the screws.
- Product last output cable is not protected IP67-IP68.
- Faulty electrical connection.
- Wrong IP68 socket-terminal block- plug connector connection.
(Wrong opening of the cable length, fauly tightening the screws etc.)
- If the IP68 Connecting kits are under water.
iPLASMA INSTALLATION GUIDE

Popular Lantern manuals by other brands

Emos P4526 manual

Emos

Emos P4526 manual

Honeywell ImperLED E quick start guide

Honeywell

Honeywell ImperLED E quick start guide

Almat STELLAsc operating manual

Almat

Almat STELLAsc operating manual

Philips UrbanSpark BDP301 Replacement

Philips

Philips UrbanSpark BDP301 Replacement

GE Lumination LVT 24 Series installation guide

GE

GE Lumination LVT 24 Series installation guide

Patriot Lighting 343-1474 installation guide

Patriot Lighting

Patriot Lighting 343-1474 installation guide

SLV BRICK DOWNUNDER E14 operating manual

SLV

SLV BRICK DOWNUNDER E14 operating manual

DS Produkte Z 02880 operating instructions

DS Produkte

DS Produkte Z 02880 operating instructions

Anslut 004259 operating instructions

Anslut

Anslut 004259 operating instructions

BEGA 33 159 Instructions for use

BEGA

BEGA 33 159 Instructions for use

Carmanah EG40 user manual

Carmanah

Carmanah EG40 user manual

Stahl PRACHT EXLUX 6401 Series operating instructions

Stahl

Stahl PRACHT EXLUX 6401 Series operating instructions

EDM 31841 manual

EDM

EDM 31841 manual

Vaughan Denmead WA0346 installation guide

Vaughan

Vaughan Denmead WA0346 installation guide

IKEA BORRBY quick start guide

IKEA

IKEA BORRBY quick start guide

ASTRO Messina Sensor 7355 instructions

ASTRO

ASTRO Messina Sensor 7355 instructions

Primus 3069 Instructions for use

Primus

Primus 3069 Instructions for use

olympia electronics KLIN-20/ST quick start guide

olympia electronics

olympia electronics KLIN-20/ST quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.