PANEL PRO
You will find that you will need to add water frequently. It may not be necessary to add
Koolmist every time, but if the color becomes less blue, then the mixture is too lean,
and it loses lubrication capability.
The cutting process will create a sludge of very fine metal particles. Plan to replace the
coolant and clean the pail every 3-4 months.
Plan to clean the chips out of the drain pan every day. The chips may be scraped uphill
in the drain pan to facilitate draining.
.
17.Place the pump and tank on the floor with the large hole positioned under drain hole
in the pan.
18.Install the drain fitting as shown with the rubber gasket against the bottom of the pan
and the fiber gasket between the
rubber and the nut. There is
nothing attached to the drain. Its
purpose is to prevent coolant
splashing beside the screen in
the pail when a large volume of
coolant is poured in the pan.
19.The controller mount bars
(shipped in the tool box) are
mounted to the front of the drain
pan. Supplied with the controller
mount bars are 8 each 6x25 mm
socket head screws. Liberally
apply silicone seal under the head of 4 of the 6mm socket head screws. Loosely
install the controller mount arms to the drain pan with these screws. Attach the SC3
controller to the arms with the remaining 4 6x25mm screws. Line up the arms and
tighten the screws.
20.Attach the X interconnect cable 16 pin
Amp connector to the controller. The
controller connector has a keying pin to
prevent installation on the Y/Z connector.
The X axis cable will have 2 connectors
with angle brackets.
The X1 axis has a 3 pin white connector
for the X axis limit switch.