Bullerjan O series User manual

Version: 10/ 2014 - We reserve the right to make changes
Operating manual
and certificate of authenticity
for
Bullerjan hot air stoves
Series O
Types 00 – 01 – 02
--- Limited edition – while stock lasts ---

Version: 10/ 2014 - We reserve the right to make changes
Operating manual and certificate of authenticy
for Bullerjan stoves Series O
Please note that all fireplaces, whether a new installation or retrofit, must be approved by a chimney sweep and/or insurance
underwriter. Contact them for specific details.
This stove is an intermittent burning appliance.
Before installing your stove, ensure that the load carrying capacity of the installation location is sufficent for the weight of the
stove including the base and combustion wood. If necessary, there must be weight adustment using a shim.
The Bullerjan GmbH points out that it is not permitted to burn waste, combustible fluids or non-suitable fuels to heat the stove.
1. Set-up/ Connections/ Installation
1.1 General operation of Bullerjan O stoves
When installing Bullerjan stoves O and when connecting them to exhaust gas systems, the relevant regluations under public law,
particularly the provisions of state construction ordinances and the approved firing regulations are to be followed.
1.2 Combustion air supply1
The room in which the stove is to be installed should at least have a minimum volume of 4 m3 per kW of nomimal heating
capacity.
The air supply for Bullerjan stoves O, Type 00, 01 and 02 will be sufficient if the room, where the stove is located is provided by
at least one door leading into the open air an by a window which can be opened.
1.3 Connecting pipes
In order to provide maximum echaust gas efficiency for the best stove operations, the stove needs to be connected to the chimney
in the shortest and straightest possible manner. Additonally, this connection should be able to be dismantled for cleaning and
inspection from time to time.
1.4 Safety distance to combustible components and furniture1
Please note the following table for deviating minimum distances to combustible components and furniture:
Model O Front Sides Back/rea
r
Floo
r
Type 00 800 mm 400 mm 650 mm 0
Type 01 800 mm 400 mm 850 mm 0
Type 02 800 mm 400 mm 850 mm 0
1.5 Chimney
Bullerjan stoves O need a chimney of their own. For the purpose of fire protection, the design of the chimney will be made
according to the EN 13384 using the triple of values indicated in the table below.
The safe operation and the rated thermal output of our Bullerjan stoves can only be guaranteed if the design of the chimney
with regard to fire protection has been proven to be calculated according o the EN 13384 and confirmed by an authorised chimney
sweep.
Triple of values
Bullerjan
–
Type „O“ Unit 00 01 02
Nominal heat capacity (NWL) kW 7,7 10,4 16,0
Exhaust gas mass flow relative to NWL g/s 14,5 12,4 13,3
Average exhaust temperature °C 378 370 366
Conveyance pressu
r
e Pa 12 12 12
NOx
–
Emission relative to 13 % O2 mg/m
3107,3 115,9 103,6
CO-Emission relative to 13 % O2
V
ol.- % 0,218 0,167 0,299
CO-Emission relative to 13 % O2 mg/m
32724 2092 3735
Dust-Emission relative to 13 % O2 mg/m
359,5 35,9 38,3
CxHy
–
Emission relative to 13 % O2 (total C as OGC) mg/m3181,5 118,9 303,2
Efficiency % 75 74 77
1 The applicability of the above mentionned values will be subject to other rules and requirements indicated in the firing regulations an building regulations
of the individual states.

Version: 10/ 2014 - We reserve the right to make changes
2. Firing / User manual
2.1 Firewood feed and permissible fuels
As a fuel, you should only use air-dried, natural hard wood (e. g. beechwood) in the form of logs with residual moisture of less
than 15 %.
The use of larger quantities of combustible wood does not increase the heating capacity to a major degree. Instead, the excess
engergy escapes to the chimney. In addition, this results in high hazardous emissions and in extreme cases can damage the
Bullerjan stove O and/or individual parts.
Never use treated or plastic-coated wood, chip boards, saw dust, card board, paper, coal, coke or similar items!
Permissible fuels (max. kg/h)
Bullerjan - Type Unit 00 01 02
Nominal heat capacity kW 7,7 10,4 16,0
Fuel quantity Kg/h 2,7 3,7 5,2
Fuele type 2 logs dry hard wood Alongside
each other
Alongside
each other
Alongside
each other
Length of wood logs 25 cm 33 cm 50 cm
Adjustment primary air valvet below the door 10 mm, 42°
open
11 mm, 45°
open
16 mm, 47°
open
Adjustment secondary air above the door ½ open 1/3 open 1/3 open
Adjustment tertiary air valvet 100 % open 50 % open 50 % open
2.2 Operating Bullerjan stoves model O
Bullerjan hot air stoves O may only be operated with thermal safety covers2 and with closed fire room dor. When igniting and for
the operation with nominal heat capacity please open the adjustments for primary, secondary and tertiary air as mentionned in the
schedule
under 2.1.
2.3 Combustion air adjustment
For the combustion air supply Bullerjan® stoves O are equipped with adjustable primary, secondary (glass washing) and tertiary
air supplies.
The glas cleaning system (secondary air supply) on top of the combustion camber door guides the secondary air along the front
glass downwards to the flame. This way, the soiling of the glass can be successful delayed. However, soiling can not be avoided
fully when burning solid fuels which naturally create soot and therefore soiling does not constitute a defect.
2.4 Heating-up procedure
Open the adjusters for the combustion air supply as mentionned in the schedule unter 2.1. Then open the fire room door and insert
the logs until just before the back wall of the stove. The logs should be placed alongside each other. Place small ignition wood or
wood chips or an ignition aid onto the logs. Ignite the igniton aid and close the stove door.
Important:
Do not use any combustible liquids like aclohol or gasoline when igniting.
Caution: HOT:
During operation, the external surfaces of the stove are very hot. No contact should be made with the stove except at the handles.
Bullerjan stoves are coated with high-quality, heat-resitant paint which only reaches ist completely solid stage the first time the
stove is used. There will be smoke formation and odour when initially heating the stoves. Therefore, when initially heating, open
the doors and windows. Please check the viewing glass installation before initial heating. The screws for the glass holder on the
front side of the fire room door may only be or become so firmly connected that the glas can still move. The sealing cord must be
clamped by the glass all around.
2.5 Cleaning and maintenance
The parts of the Bullerjan® stoves O which carry flue gas and the connection pieces must be cleaned in the event of soiling, at
least once during and after the heating period. This can be done with an ash vaccuum..
Bullerjan stoves O are working with an ash grate and an ash box. The ash grate should be cleaned of combustion residues. This
can be done with a clean out. The ash box must be emptied regularly in cold condition. To remove the ash box, please lift the ash
grate. Please do not put glowing material in the trash.
The company Bullerjan GmbH requests your understanding that our warranty claim to the Bullerjan stoves becomes invalid if you
put too much strain on your stove by using non-permissible fuels oder by loading with fuel quantities which are excessively large.
2 Not necessary, if Bullerjan hot air stoves O are enrased or strucurally covered. The encasing of the stoves may only be performed by
specialised licensed companies in the in-built stove and installation business.

Version: 10/ 2014 - We reserve the right to make changes
Certificate of authenticity and double counter-piece of the
hologram type plate on your
Bullerjan stove model O
Bullerjan hot air stoves model O meet the requirements of EN 13240.
Please see the corresponding Declarations of performance on www.bullerjan.com!
Bullerjan GmbH Neuwarmbüchener Straße 2 30916 Isernhagen Tel.
+49(0)5136/9775-0 www.bullerjan.com
Table of contents
Other Bullerjan Stove manuals
Popular Stove manuals by other brands

Nibe
Nibe Contura C750 instructions

Dimplex
Dimplex EOS-2006 Practical user's guide

superior fires
superior fires HAMBLETON Installation & user's instructions

Jolly Mec
Jolly Mec CULT 8 kW UP Instructions for installation, use and maintenance manual

Travis Industries
Travis Industries Avalon owner's manual

Heartland Appliances
Heartland Appliances Oval 1902 Installation and operating instructions