Airsupply
Allhydrocarbonburningappliancesrequireanoxygen/airsupply.
If the stove is to be fitted on an external wall the air supplycanbetaken
straightfromtheoutside.A100mmdiameterholeneedstobedrilledinthe
correctplace(138mmabovethehearth)totakethe86mmexternal(80mm
internal)ductassupplied.
Thiswillallowforeasyconnection,anygapcanbefilledinwithcementor
mastic.
Aproprietarygrilleissuppliedwiththekit.
Iftheroomsealingkitisnotused,anairbrickornon‐closingventshouldbe
fittedtoensuretheairsupplyisnotblockedinanyway.
Ventilationisnotrequiredonthe3kW&4kWmodels.
Asideventoptiontotheroomsealingkitisavailable.
RoomSealingKit
Theroomsealingmethodofsupplyingairisalwaystobepreferredasheat
lossfromtheroomwillbegreatlyreducedthereforeincreasingthe
efficiencyoftheappliance.
Ifthestoveisnotonanoutsidewallorthedirectairsupplymethodcannot
beused,anairventmustbesuppliedintheroominwhichthestoveis
fitted.Thesizesoftheventsrequiredare:
3kW‐Noventrequired(Usingtheroomsealingkitwillincreaseefficiency)
4kW‐Noventrequired(Usingtheroomsealingkitwillincreaseefficiency)
5kW‐550mmsqrequired(Forhomesbuiltbefore2010noairventrequirement.)
8kW‐1650mmsq(50mmdiameter)
12kW4950mmSq(100mmdiameter)
Onlypermanentlyopenventscanbeusedandconsiderationshouldbegiven
todraughtwhenthestoveisnotinuse,thereforesitethisventcarefully.
TheventcoversshouldcomplywithBuildingRegulationsPartJandshould
besitedwheretheycannotbeblocked.