The Contractors Choice
thermOweld®
ECN 2552 REV "B" 03/06/13 34-5657-34
+1 (918) 627-5210 • 1-800-558-1373 • WWW.THERMOWELD.COM
ELECTRICAL GROUNDING • CATHODIC PROTECTION • ELECTRIC UTILITY • RAIL
Tel. +1.800.558.1373
Tel. +1.918.627.5210
www.thermoweld.com
INSTRUCTIONS FOR THERMOWELD GROUNDING CONNECTIONS - BAR TO BAR
M-10310 BB-99
Place bus bars into mold
as shown.
Follow instructions on
back of this sheet.
M-10311 BB-99
Place bus bars into mold
as shown.
Follow instructions on
back of this sheet.
25 to 20 mm
overlaping
1-800-558-1373 • SALES • SERVICE • TECHNICAL SUPPORT • VISIT www.thermOweld.com
t
h
e
r
m
O
w
e
l
d
®
Z
Z
E
E
Pa tented
E
Z
L
i
t
e
®
M
o
l
d
GENERAL SAFETY INSTRUCTIONS
1. Always wear proper clothing, safety glasses and gloves when
exothermic welding.
2. Only weld items mold is designed for.
3. Do not use worn or broken molds which could cause leakage
of molten weld metal.
4. Make sure that the material being welded ts in the mold
properly and that the mold will close tightly around them.
5. Do not alter molds or accessories without factory
authorization.
6. Avoid breathing concentrations of smoke, as it may be
hazardous to your health.
7. Avoid contact with hot materials.
8. Remove or protect re hazards in the welding area.
9. Avoid moisture and contaminants in the mold and materials
being welded. Contact of molten weld metal with moisture or
contaminants may cause weld metal to spew out of mold.
10. When welding to pipe or vessels, you should consider
the following:
a. the effect welding may have on structural members
and thin wall pipe or vessels.
b. pipe or vessels that are pressurized or contain (or
have contained) ammable, explosive or hazardous
materials should be evaluated in the case of a melt-
through or hot molten weld metal coming in contact
with any ammable, explosive or hazardous materials.
11. Failure to abide by the above and follow welding procedures
may result in improper welds, damage to the material being
welded or create hazardous situations for the individual.
PREPARATION OF BUS BAR, LUGS & COPPER STRIP
1. Bus bar and lugs must be bright, clean and dry on all
surfaces that are within the weld area in the mold.
2. Use a le or card cloth brush to remove oxides.
WELDING PROCEDURE
1. Check mold tag for material to be welded and proper cartridge
size to use.
2. Make sure all surfaces and conductors are clean, dry and are
the proper sizes for the molds application per mold tag.
3. Molds can be dried by heating to approximately 250ºF. Molds
may be dried with a hand operated butane torch or by ring a
charge in the mold before making the desired weld.
4. Position mold onto conductor(s). See front of this sheet for
positioning of conductors into mold. Lock mold with handle
clamps or frame, whichever is the case.
5. Insert steel disk being sure it is directly centered over the
tap hole. Failure to insert disk into mold or failure to seat the
disk properly can create an improper weld and may cause
mold to spew weld metal.
6. Pour proper weld cartridge(s) into crucible being careful not to
loosen all the starting powder while pouring weld metal into
mold. Use of wrong weld cartridge can cause improper welds
or damage to molds.
7. Close the lid of the mold and place a small amount of starting
powder in the ignition pocket.
OR
Insert the EZ Lite®ignitor in the connector of thermOweld EZ
Lite Remote™ Unit. Close the lid and place the ignitor in the
top opening of the EZ Lite®Lid allowing the connector to rest
on the lid.
8. Before igniting, verify conductor positioning and that mold is
closed completely.
9. Ignite the starting powder with the int ignitor. Pull int ignitor
away from starting powder right after trigger is pulled to keep
from fouling int ignitor. (Do not place any exposed body part
directly over lid or in front of lid opening.)
OR
Turn the power button to the “ON” position on the EZ Lite
Remote™ Unit followed by the “operate” button until the
exothermic reaction is initiated.
10. Wait for 15 seconds before opening mold to allow weld metal
to cool.
11. To clean the mold, use a natural bristle brush, soft cloth or
newspaper before making next weld. On horizontally split
molds, use a small diameter rod or screw driver to remove
slag from tap hole. Caution should be used when cleaning
molds to avoid burns from contact with hot mold.
DO NOT USE WIRE BRUSH TO CLEAN MOLD!
NOTE: 1. A fouled int ignitor may be cleaned by soaking in
house hold ammonia.
2. Proper cartridge size is marked on mold tag and
shown on the bottom of the cartridge tube.
3. Cartridge size is the approximate weight of the powder
in grams. When the cartridge size specied is not
available, two or more smaller cartridges or part of a
larger cartridge may be used. Care should be taken
not to mix starting material in-between cartridges.
4. Handle Clamp adjustments may be made by removing
cotter pin and clevis pin and turning eye bolt one turn
clockwise to tighten or one turn counter clockwise to
loosen.

This manual suits for next models

1

Other Burndy Cables And Connectors manuals

Burndy Continental thermOweld CS-32 User manual

Burndy

Burndy Continental thermOweld CS-32 User manual

Burndy Continental Industries ThermOweld CC-1 User manual

Burndy

Burndy Continental Industries ThermOweld CC-1 User manual

Burndy Continental Industries ThermOweld CB-9 User manual

Burndy

Burndy Continental Industries ThermOweld CB-9 User manual

Burndy Continental Industries ThermOweld CR-26 User manual

Burndy

Burndy Continental Industries ThermOweld CR-26 User manual

Burndy Continental Industries ThermOweld CR-18 User manual

Burndy

Burndy Continental Industries ThermOweld CR-18 User manual

Burndy Continental Industries thermOweld BRE-7 User manual

Burndy

Burndy Continental Industries thermOweld BRE-7 User manual

Burndy Continental Industries ThermOweld CB-1 User manual

Burndy

Burndy Continental Industries ThermOweld CB-1 User manual

Burndy ACC-FWT User manual

Burndy

Burndy ACC-FWT User manual

Burndy Continental Industries thermOweld CB-18 User manual

Burndy

Burndy Continental Industries thermOweld CB-18 User manual

Burndy Continental Industries CC-37 User manual

Burndy

Burndy Continental Industries CC-37 User manual

Burndy Continental Industries thermOweld CRE-7 User manual

Burndy

Burndy Continental Industries thermOweld CRE-7 User manual

Burndy Wiley ACC-F90-1 User manual

Burndy

Burndy Wiley ACC-F90-1 User manual

Burndy Continental Industries ThermOweld CC-8 User manual

Burndy

Burndy Continental Industries ThermOweld CC-8 User manual

Burndy Continental Industries ThermOweld CB-8 User manual

Burndy

Burndy Continental Industries ThermOweld CB-8 User manual

Burndy Continental Industries ThermOweld CR-4 User manual

Burndy

Burndy Continental Industries ThermOweld CR-4 User manual

Burndy Continental Industries ThermOweld BRE-3 User manual

Burndy

Burndy Continental Industries ThermOweld BRE-3 User manual

Burndy Continental Industries thermOweld CB-15 User manual

Burndy

Burndy Continental Industries thermOweld CB-15 User manual

Burndy Continental Industries thermOweld CX-6 User manual

Burndy

Burndy Continental Industries thermOweld CX-6 User manual

Burndy Continental Industries ThermOweld CR-27 User manual

Burndy

Burndy Continental Industries ThermOweld CR-27 User manual

Burndy Continental Industries thermOweld CP-1 User manual

Burndy

Burndy Continental Industries thermOweld CP-1 User manual

Burndy Continental Industries thermOweld CR-5 User manual

Burndy

Burndy Continental Industries thermOweld CR-5 User manual

Burndy Continental Industries ThermOweld CR-28 User manual

Burndy

Burndy Continental Industries ThermOweld CR-28 User manual

Burndy YCP4CL Series Guide

Burndy

Burndy YCP4CL Series Guide

Burndy Continental Industries ThermOweld CRE-11 User manual

Burndy

Burndy Continental Industries ThermOweld CRE-11 User manual

Popular Cables And Connectors manuals by other brands

Alpine KWE-901G7MIC user guide

Alpine

Alpine KWE-901G7MIC user guide

Philips SWV3010W Specifications

Philips

Philips SWV3010W Specifications

Philips SDJ6360W Specifications

Philips

Philips SDJ6360W Specifications

Edsbyn CONNECT Assembly instruction

Edsbyn

Edsbyn CONNECT Assembly instruction

Lindy 43322 user manual

Lindy

Lindy 43322 user manual

ATX SignalOn Series Installation & operation manual

ATX

ATX SignalOn Series Installation & operation manual

Werner A330000 quick start guide

Werner

Werner A330000 quick start guide

Leviton eXtreme 6+ Connector 61110-Rx6 Specifications

Leviton

Leviton eXtreme 6+ Connector 61110-Rx6 Specifications

Renkforce 1404051 operating instructions

Renkforce

Renkforce 1404051 operating instructions

Philips SWV3030W Specifications

Philips

Philips SWV3030W Specifications

Tyco Electronics 58449-1 instruction sheet

Tyco Electronics

Tyco Electronics 58449-1 instruction sheet

Infineon EZ-PD user guide

Infineon

Infineon EZ-PD user guide

Bticino F441 Instructions for use

Bticino

Bticino F441 Instructions for use

VOLTCRAFT BS-19 operating instructions

VOLTCRAFT

VOLTCRAFT BS-19 operating instructions

Sumitomo Lynx-CustomFit LYNX2-FC installation manual

Sumitomo

Sumitomo Lynx-CustomFit LYNX2-FC installation manual

Panduit FSCMM Series installation instructions

Panduit

Panduit FSCMM Series installation instructions

Philips SWA2083 Specifications

Philips

Philips SWA2083 Specifications

Alemite 7340 Service guide

Alemite

Alemite 7340 Service guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.