Operating Instructions
Technical data
Operating Instructions | 1473-1-8378 — 4 —
Pos:9 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alleDokumente<--)/1. Ebene/S - T/Techni sche Daten @ 11\mod_127918 5386320_15.docx @ 83019 @ 1 @ 1
3 Technical data
Pos: 10 /#Neustruktur #/Online-Doku mentation (+KNX)/Techni sche Daten/Sicher heitstechnik/Busc h-Rauchalarm/Techni sche Daten - 6831-6832-84 @ 36\ mod_1369206702890_15. docx @ 296237 @ 11 @ 1
6831-84
Power supply (replaceable block battery) 9 Volt
Battery service life 18 months
6832-84
Power supply (permanently installed lithium
battery) 2,000 mAh
Battery service life 10 years
General
Operational readiness - visual display with a red
LED every 40 seconds 85 dB(A)
Sound pressure 0°C … 40°C
Operating temperature - 10 °C to + 60 °C
Storage temperature 115 mm x 45 mm
Dimensions DIN EN 14604 / DIN 14676 / CE / ISO 9001 2000
Standards VdS G208016
Certification 200 g
Weight 15% to 95% rel
Humidity, no condensation 85 dB(A)
Pos:11 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften(--> Für alle Dokumente<--)/1. Ebene/A - F/ Aufbau und Funktion @ 11\mod_1279185 435352_15.doc x@ 83027 @ 112 2 @ 1
4 Setup and function
Pos: 12 /#Neustruktur #/Online-Dokumen tation (+KNX)/Aufbau un d Funktion/Sicher heitstechnik/Busch- Rauchalarm/Funk tionen - 6831-6832-84 @ 36\mod_1369 206685157_15.doc x @ 296221 @ 11 @ 1
The smoke detector works according to the scattered light principle. It detects smoke particles floating in the air.
Therefore, ensure that air can at all times enter the lateral slats of the smoke detector unhindered.
The device responds early and reliably to smoldering fires and open fires with smoke.
Avoid situations in which the device is subjected to draught (open window and / or ventilators). Use only the
specified type of batteries.
Pos:13 /#Neustruktur#/Online-Dokumentation(+KNX)/Steuermodule- Online-Dokumentation(--> Für alleDokumente<--)/++++++++++++Seitenumbruch + +++++++++++ @ 9\mod_12688 98668093_0.docx @ 52149 @ 11 @ 1