Busch-Wachter 6847 220 MasterLINE User manual

1
473-1-8102 │Rev. 01 │11.2012
O
perating Instructions
Busch-Wächter®
Pos: 2 /#Neustruktur#/ Online-Dokumentati on (+KNX)/Titelbl ätter/Waechter /Titelblatt - 6847-6867- MasterLINE -- BJ E @ 24\mod_1338458140180_15. docx @ 214600 @ @ 1
6847 220 MasterLINE
6867 280 MasterLINE
=== Ende der Liste für TextmarkeCo ver ===

Operating Instructions
Busch-Wächter®
Operating Instructions | 1473-1-8102 — 2 —
Pos: 4 /#Neustruktur#/ Online-Dokumentati on (+KNX)/Inhalts verzeichnis (- -> Für alle Dokumente <-- )/Inhaltsverzeichni s @ 19\mod_1320649044386_ 15.docx @ 109653 @ @ 1
1Safety....................................................................................................................................................................... 3
2Intended use ............................................................................................................................................................ 3
3Environment............................................................................................................................................................. 3
4Setup and function................................................................................................................................................... 4
4.1 Busch-Watchdog 220 MasterLINE.......................................................................................................... 4
4.2 Busch-Watchdog 280 MasterLINE.......................................................................................................... 4
4.2.1 General ................................................................................................................................................... 4
4.3 Features of function and equipment........................................................................................................ 4
4.4 Detection ranges..................................................................................................................................... 5
4.4.1 Overview of the detection range for Busch-Watchdogs 220 - 280 MasterLINE ...................................... 5
4.4.2 Limitation of the detection range ............................................................................................................. 5
4.5 Busch-Watchdog 220Ԝ/Ԝ280MasterLINE................................................................................................... 5
5Technical data.......................................................................................................................................................... 6
6Installation and electrical connection ....................................................................................................................... 7
6.1 Requirements for the electrician ............................................................................................................. 7
6.2 Mounting ................................................................................................................................................. 8
6.2.1 Mounting methods .................................................................................................................................. 8
6.2.1.1 Wall mounting ......................................................................................................................................... 8
6.2.1.2 Wall mounting with gradient. ................................................................................................................... 9
6.2.1.3 Ceiling mounting ..................................................................................................................................... 9
6.2.2 Corner mounting ................................................................................................................................... 10
6.2.3 Installation sites .................................................................................................................................... 10
6.2.4 Preparing the installation....................................................................................................................... 11
6.2.5 Mounting steps...................................................................................................................................... 12
6.3 Electrical connection ............................................................................................................................. 13
6.3.1 Standard connection ............................................................................................................................. 13
6.3.2 Standard connection with extension unit push-button........................................................................... 13
6.3.3 Standard connection with RC suppressor 6899 and relay .................................................................... 13
7Commissioning ...................................................................................................................................................... 14
7.1 Setting / limiting the coverage and the detection range......................................................................... 14
7.2 Activation test........................................................................................................................................ 15
8Operation ............................................................................................................................................................... 16
8.1 Control elements................................................................................................................................... 16
8.2 Standard operation ............................................................................................................................... 16
8.3 Standard operation (time- and brightness dependent).......................................................................... 17
8.4 Auxiliary post operation......................................................................................................................... 17
8.4.1 Operation with extension unit push-button............................................................................................ 17
9Remote control....................................................................................................................................................... 18
9.1 Control elements of the remote control ................................................................................................. 18
9.2 Technical data of the remote control ..................................................................................................... 18
9.3 Commissioning of remote control.......................................................................................................... 19
9.4 Battery change of remote control .......................................................................................................... 19
=== Ende der Liste für Te xtmarke TOC ===

Operating Instructions
Busch-Wächter®Safety
Operating Instructions | 1473-1-8102 — 3 —
Pos:6 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften(-->Für alleDokumente<--)/1. Ebene/S - T/Sic herheit @ 18\mod_130261279179 0_15.docx @ 103357 @ 1 @ 1
1 Safety
Pos:7 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweiseund Hinweise(--> Für alleDokumente<--)/Warnhinweise/Sicherheit- 230V @ 18\ mod_1302606816750_15. docx @ 103308 @ @ 1
Warnin
g
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos:8 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften(-->Für alleDokumente<--)/1. Ebene/A - F/ Bestimmungsgemäßer Gebrauc h @ 18\mod_1302763321316_15. docx @ 103483 @ 1 @ 1
2 Intended use
Pos: 9 /#Neustruktur#/ Online-Dokumentati on (+KNX)/Besti mmungsgemäßer Gebrauch ( --> Für alle Dokumente <- -)/Busch-Dimmer/Besti mmungsgemäßer Gebrauc h @ 23\mod_13353504498 57_15.docx @ 208763 @ @ 1
The device is to be used exclusively with the components that are supplied and licensed as described in chapter
"Setup and function".
Pos: 10.1 /#Neustrukt ur#/Modul-Strukt ur/Online-Dokumen tation/Überschr iften (--> Für alle Dokument e <--)/1. Ebene/U - Z/Um welt @ 18\mod_1302614158 967_15.docx @ 103383 @ 1 @ 1
3 Environment
Pos:10.2 /#Neustruktur#/Online-Dokumentation(+KNX)/Sicherheitshinweiseund Hinweise(--> FüralleDokumente <--)/Hinweise/Hinweis- Umwelt- HinweisEl ektrogeräte @ 18\mod_130 2763973434_15.doc x @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with domestic waste.
– The device contains valuable raw materials which can be recycled. Therefore, dispose of the
device at the appropriate collecting depot.
Pos:10.3 /#Neustruktur#/Online-Dokumentation(+KNX)/Sicherheitshinweiseund Hinweise(--> FüralleDokumente <--)/Hinweise/Hinweis- Umwelt- Entsorgung Elektrogeräte @ 20\ mod_1325760695972_15. docx @ 136583 @ @ 1
All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the
packaging material and electric devices and their components via the authorized collecting depots and disposal
companies.
The products meet the legal requirements, in particular the laws governing electronic and electrical devices and
the REACH ordinance.
(EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS)
(EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006)
Pos:11 /#Neustruktur#/Online-Dokumentation(+KNX)/Steuermodule- Online-Dokumentation(--> Für alleDokumente<--)/++++++++++++Seitenumbruch + +++++++++++ @ 9\mod_12688 98668093_0.doc x@ 52149 @ @ 1

Operating Instructions
Busch-Wächter®Setup and function
Operating Instructions | 1473-1-8102 — 4 —
Pos:12 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/1. Ebene/A - F/ Aufbau und Funktion @ 11\mod_1279185 435352_15.doc x@ 83027 @ 111 @ 1
4 Setup and function
Pos: 13 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Aufbau un d Funktion/Waechter /Funktionen - 6847-686 7 220-280 MasterLINE @ 28\mod_1347514 544179_15.doc x@ 23316 3 @ 2223 @ 1
4.1 Busch-Watchdog 220 MasterLINE
The Busch-Watchdog 220 MasterLINE is a movement detector with a detection range of 220° and
is suitable for use in the home and for mounting to the wall or ceiling.
The Busch-Watchdog is ideally suited for larger properties and free-standing buildings.
4.2 Busch-Watchdog 280 MasterLINE
The Busch-Watchdog 280 MasterLINE is a movement detector with a detection range of 280° and
is suitable for use in the home and for mounting to the wall or ceiling.
The Busch-Watchdog is ideal for the surveillance of two sides of a building.
4.2.1 General
The Busch-Watchdogs are passive infrared movement detectors which switch loads via the KNX bus when
sources of heat move within its detection range.
Busch Watchdog is not an intrusion or attack alarm.
Pos:14 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/2. Ebene/A - F/ Funktions- und Ausstattu ngsmerkmale @ 23\mod_1 336557630140_15.doc x@ 2091 36 @ 2 @ 1
4.3 Features of function and equipment
Pos: 15 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Aufbau un d Funktion/Waechter /Ausstattungsmerk male - 6847-6867 220-280 Ma sterLINE @ 29\mod_1348044135 054_15.docx @ 234009 @ 1 @ 1
Comparison of functions:
Function Busch-Watchdog 220 Busch-Watchdog 280
Coverage of 16 m x x
Wider lens - x
Operating mode, twilight setting, switch-off delay and short-time pulse x x
A
utomatic interference suppression and presence simulation x x
Range stabilisation x x
Operation via remote control x x
Extension unit operation x x
Use of corner adapter - x
Note about surveillance of two sides of a building
Detection of two sides of a building only possible with the corner adapter!
More details are available in chapter 6.2.2 "Mounting methods" for corner adapter on page 10.
Pos:16 /#Neustruktur#/Online-Dokumentation(+KNX)/Steuermodule- Online-Dokumentation(--> Für alleDokumente<--)/++++++++++++Seitenumbruch + +++++++++++ @ 9\mod_12688 98668093_0.doc x@ 52149 @ 11 @ 1

Operating Instructions
Busch-Wächter®Setup and function
Operating Instructions | 1473-1-8102 — 5 —
Pos:17 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/2. Ebene/A - F/ Erfassungsbereiche @ 19\ mod_1320393658466_15. docx @ 109558 @ 22333 @ 1
4.4 Detection ranges
Pos:18 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/3. Ebene/U - Z/Über sicht der Erfassungs bereiche Busch-W ächter 220-280 @ 28\mod_13475176 34430_15.docx @ 233219 @ 333 @ 1
4.4.1 Overview of the detection range for Busch-Watchdogs 220 - 280 MasterLINE
Pos: 19 /#Neustruktur #/Online-Dokumen tation (+KNX)/Erf assungsbereiche/W aechter/Erfassungsber eiche - 6847-6867 220-28 0 MasterLINE @ 28\mod_13475 14597367_15.docx @ 233177 @ 1333 @ 1
Fig. 1: Detection ranges
Detection range
• The detection range is 220° and 280° and the coverage is 16 m.
• The movement detector also has rearfield detection of one meter.
Wall mounting
• The movement detector offers optimum surveillance if mounted to the wall at a maximum height of 2.5 m.
Pos:20 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/3. Ebene/A - F/ Erfassungsbereiche Red uzierung @ 29\mod_13476 12043430_15.doc x@ 2336 18 @ 22222 @ 1
4.4.2 Limitation of the detection range
Pos: 21 /DinA4 - Anleitung en Online/Inhalt/W aechter/Erfassungsb ereiche Einengung - 220° - 280° @ 28\mod_1347516663330_15. docx @ 233205 @ 22 @ 1
4.5 Busch-Watchdog 220Ԝ/Ԝ280MasterLINE
Use of adhesive film:
The horizontal detection ranges of the Busch-Watchdogs are 220° and 280°. The detection range can be limited
in case of special local circumstances.
To do this, proceed as follows.
1. Cut the included adhesive film to the desired length.
2. Glue the section of covering foil from the front onto the area of the lens of your Busch-Watchdog where the
detection is to be blocked out.
Note
For an illustration see chapter 7.1 on page 14.
Pos:22 /#Neustruktur#/Online-Dokumentation(+KNX)/Steuermodule- Online-Dokumentation(--> Für alleDokumente<--)/++++++++++++Seitenumbruch + +++++++++++ @ 9\mod_12688 98668093_0.doc x@ 52149 @ 1 @ 1
2,5 m
max. 16 m
16 m1 m
max. 16 m
220° 280°

Operating Instructions
Busch-Wächter®Technical data
Operating Instructions | 1473-1-8102 — 6 —
Pos:23 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/1. Ebene/S - T/Tec hnische Daten @ 11\mod_127 9185386320_15.doc x@ 83019@ 112 @ 1
5 Technical data
Pos: 24 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Techni sche Daten/Waec hter/Technische Daten - 6847- 6867 MasterLINE @ 24\mod_1338 458229291_15.doc x@ 214 614 @ 2 @ 1
Designation Value
Nominal voltage 230 V AC ± 10% 50 / 60 Hz
Switching capacity 3680 W/VA
Maximum switching current: 16 AX
Maximum power loss < 1 W
Horizontal detection
• Busch-Watchdog 220 220°
• Busch-Watchdog 280 280°
Twilight sensor 0.5 … 300/∞lux
Switch-off delay 10 seconds … 30 minutes
Short-time pulse
• Pulse duration 1 second
• Pause time 9 seconds
• Pause time with continuous light /
presence simulation
55 seconds
Coverage
(if mounted 2.5 m high)
Maximum of 16 m
Operating temperature -25°C … 55°C
Protection type IP 55
Pos: 25 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Sic herheitshinweise und Hin weise (--> Füralle Dokumente<--)/Hinweise- Allgemein/Hinweis- Anschlussvon EVG's- Herstellerangaben @ 24\mod_1338458660462 _15.docx @ 214629 @ @ 1
Information for the connection of ballasts
Please observe the following points regarding high inrush currents for ballasts:
- The ballast manufacturer’s specification determines the possible number of ballasts.
Pos:26 /#Neustruktur#/Online-Dokumentation(+KNX)/Steuermodule- Online-Dokumentation(--> Für alleDokumente<--)/++++++++++++Seitenumbruch + +++++++++++ @ 9\mod_12688 98668093_0.doc x@ 52149 @ 221 @ 1

Operating Instructions
Busch-Wächter®Installation and electrical
connection
Operating Instructions | 1473-1-8102 — 7 —
Pos:27 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/1. Ebene/M - O/Mon tage und elektrischer Anschluss @ 23\mod_133647715786 4_15.docx @ 209033 @ 3333 @ 1
6 Installation and electrical connection
Pos: 28 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Sic herheitshinweise und Hin weise (--> Füralle Dokumente<--)/Warnhinweise/Sicherheit- Niederspannungs- und23 0 V-Leitungen @ 23\mod_13365 58868201_15.doc x@ 209 164 @ 2 @ 1
Warnin
g
Electric voltage!
Risk of death due to electrical voltage of 230 V during short-circuit in the low-voltage line.
- Low-voltage and 230 V lines must not be installed together in a flush-mounted socket!
Pos: 29 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Sic herheitshinweise und Hin weise (--> Füralle Dokumente<--)/Warnhinweise/Sicherheit- Fachkenntnisse @ 23\mod_1336 559183027_15.docx @ 209179 @ 112@ 1
6.1 Requirements for the electrician
Warnin
g
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
• Incorrect installation endangers your life and that of the user of the electrical system.
• Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
• Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth and short-circuit;
5. Cover or barricade adjacent live parts.
• Use suitable personal protective clothing.
• Use only suitable tools and measuring devices.
• Check the supply network type (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
Pos:30 /#Neustruktur#/Online-Dokumentation(+KNX)/Steuermodule- Online-Dokumentation(--> Für alleDokumente<--)/++++++++++++Seitenumbruch + +++++++++++ @ 9\mod_12688 98668093_0.doc x@ 52149 @ 322 2 @ 1

Operating Instructions
Busch-Wächter®Installation and electrical
connection
Operating Instructions | 1473-1-8102 — 8 —
Pos:31 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/2. Ebene/M - O/Mon tage @ 18\mod_130261596045 8_15.docx @ 103424 @ 32344433 33 @ 1
6.2 Mounting
Pos: 32 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Sic herheitshinweise und Hin weise (--> Füralle Dokumente<--)/Warnhinweise/Sicherheit- 230 V @ 18\mod_13026 06816750_15.doc x@ 1033 08 @ 31 @ 1
Warnin
g
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 33 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Montage/ Waechter/Montage - 6847-6867_220-280 MasterLI NE@ 24\mod_1338446781648_1 5.docx @ 214481 @ 22222222422 3333 @ 1
Caution
Risk of damaging the device!
The lens of the device is sensitive and
can easily sustain damage.
- Do not press on the lens when
setting the device!
6.2.1 Mounting methods
There are four methods of mounting the Busch-Watchdog MasterLINE range.
The mounting hole is compatible with all previously available Busch-Watchdog models.
The possible mounting methods are described in the following.
Note
The adapters for the following mounting methods must be ordered separately:
- Wall mounting with gradient
- Ceiling mounting (for the desired position)
- Corner adapter
6.2.1.1 Wall mounting
Fig. 2: Wall mounting
Classic wall mounting

Operating Instructions
Busch-Wächter®Installation and electrical
connection
Operating Instructions | 1473-1-8102 — 9 —
6.2.1.2 Wall mounting with gradient.
Fig. 3: Wall mounting with gradient.
Wall mounting with gradient is recommended on a building situated on a hill or with a gradient. This allows the
detection ranged to be used effectively.
6.2.1.3 Ceiling mounting
Fig. 4: Ceiling mounting
There are two options for ceiling mounting:
1. From the bottom for a wider detection range.
2. With a corner adapter, which allows the device to be ideally positioned.

Operating Instructions
Busch-Wächter®Installation and electrical
connection
Operating Instructions | 1473-1-8102 — 10 —
6.2.2 Corner mounting
Fig. 5: Corner mounting
The combination with a corner adapter is recommended for an optimal 280° detection range.
Note
Detailed user information is available via the link http://www.busch-jaeger-katalog.de/index.php
in the Busch-Watchdog category under accessories.
6.2.3 Installation sites
Fig. 6: Installation sites
• Ceiling mounting in narrow rooms is not recommended.
• The mounting height of the device should be between 1.7 m and 2.5. m.
• The distance between light and movement detector should be at least 1.5 m.
• For optimum detection of persons the approach into the detection range should always be offset and never
frontal.
>1,7 m

Operating Instructions
Busch-Wächter®Installation and electrical
connection
Operating Instructions | 1473-1-8102 — 11 —
6.2.4 Preparing the installation
To prepare the installation of the device, perform the following steps:
Fig. 7: Preparing the installation
1. Remove the locking screw (1) (if installed).
2. Press in the clamps (2 ... 5) on the sides of the housing with a suitable tool.
3. Carefully remove the front of the device.
Fig. 8: Opening the water drain
Depending on where the device is installed, the water drain may have to be opened.
• To do this, pierce the plastic membrane on the bottom of the device.
The installation is prepared.
1
23
4
5

Operating Instructions
Busch-Wächter®Installation and electrical
connection
Operating Instructions | 1473-1-8102 — 12 —
6.2.5 Mounting steps
Fig. 9:
1. Mount the device to the wall.
- Do not use countersunk head screws for mounting
to the wall.
- Use screws with a head diameter of 6.5 mm - 8.5
mm.
2. Connect the power to the device, see section 6.3.
- Observe the maximum admissible cable cross
sections.
- The bolting dimensions of the base may be
compatible with existing bores on older versions of
the Busch-Watchdog.
- Latch the upper part of the device onto the base.
3. To protect the device against unauthorized opening, the
enclosed screw can be used on the bottom of the
device.
- To protect the device against unauthorized opening,
screw the enclosed screw into the bottom of the
device.
Pos:34 /#Neustruktur#/Online-Dokumentation(+KNX)/Steuermodule- Online-Dokumentation(--> Für alleDokumente<--)/++++++++++++Seitenumbruch + +++++++++++ @ 9\mod_12688 98668093_0.doc x@ 52149 @ 323 3 @ 1
∅6,5 mm - 8,5 mm
∅3,5 mm - 3,9 mm
mm5,41.xam
²mm
5
,2-5,1

Operating Instructions
Busch-Wächter®Installation and electrical
connection
Operating Instructions | 1473-1-8102 — 13 —
Pos:35 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/2. Ebene/A - F/ Elektrischer Anschluss @ 21\mod_1328177051724_15.doc x @ 138042 @ 223233 @ 1
6.3 Electrical connection
Pos: 36 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Anschl uss/Waechter/Ansc hluss - 6847-6867 220-280 MasterLINE @ 24\mod_1338459376540_15. docx @ 214643 @ 11133 @ 1
6.3.1 Standard connection
Fig. 10: Universal relay insert
6.3.2 Standard connection with extension unit push-button
Fig. 11: Universal relay insert with extension unit push-button
Note
For more information see chapter "Extension unit operation" 8.4 on page 17.
6.3.3 Standard connection with RC suppressor 6899 and relay
Fig. 12: Universal relay insert with RC suppressor 6899 and relay
Pos:37 /#Neustruktur#/Online-Dokumentation(+KNX)/Steuermodule- Online-Dokumentation(--> Für alleDokumente<--)/++++++++++++Seitenumbruch + +++++++++++ @ 9\mod_12688 98668093_0.doc x@ 52149 @ 212 @ 1
NL
16A
N
L
N
L
NL
16A
NL
N
L
16A

Operating Instructions
Busch-Wächter®Commissioning
Operating Instructions | 1473-1-8102 — 14 —
Pos:38 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/1. Ebene/G - L/ Inbetriebnahme @ 11\mod_127 9185496977_15.doc x@ 83035 @ 1222@ 1
7 Commissioning
Pos: 39 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Inbetri ebnahme/Waechter /Inbetriebnahme - 6847-68 67 -- 220-280 Master LINE @ 24\mod_1338448339 667_15.docx @ 214542 @ 322123 3 @ 1
7.1 Setting / limiting the coverage and the detection range
Caution
Risk of damaging the device!
The lens of the device is sensitive and
can easily sustain damage.
- Do not press on the lens when
setting the device.
Use the following steps to set the coverage and the detection range:
Fig. 13: Adjusting the lateral detection range
1. Adjust the lateral detection range by turning the head of the device.
Fig. 14: Adjusting the coverage
2. Adjust the coverage by lifting or lowering the head of the device.
– The minimum coverage is 6 m.
30°

Operating Instructions
Busch-Wächter®Commissioning
Operating Instructions | 1473-1-8102 — 15 —
Fig. 15: Adjusting the detection range by masking
3. The range can be specifically limited by gluing on the enclosed foil.
– Cut the enclosed foil to the size required.
The coverage and the detection range are set.
7.2 Activation test
The activation test can also be triggered via the service remote control (see separate operating manual).
Fig. 16: Control element
To carry out the activation test, perform the following steps:
1. Set selector switch to T/S.
- The device is now in test mode for 10 minutes (daytime operation, switch-off delay 2 sec.). In addition,
each detection is indicated by the status LED flashing quickly.
- The device then switches back to standard operating mode.
2. To carry out an additional activation test, set the selector switch back to position T/S or interrupt the operating
voltage supply for more than 15 seconds.
- The device is now in test mode for another 10 minutes. Test mode is exited automatically after 10 minutes
or by adjusting the brightness.
The activation test has been carried out.
Pos:40 /#Neustruktur#/Online-Dokumentation(+KNX)/Steuermodule- Online-Dokumentation(--> Für alleDokumente<--)/++++++++++++Seitenumbruch + +++++++++++ @ 9\mod_12688 98668093_0.doc x@ 52149 @ 112 2 @ 1
T/ S
0
315
5
1min
10
sek

Operating Instructions
Busch-Wächter®Operation
Operating Instructions | 1473-1-8102 — 16 —
Pos:41 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/1. Ebene/A - F/ Bedienung @ 11\mod_12791855416 49_15.docx @ 83043 @ 2221 @ 1
8 Operation
Pos: 42 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Bedienu ng/Waechter/Bedi enung - 6847-6867 @ 24\mod_13 38459472320_15.doc x @ 214658 @ 22333222 @ 1
8.1 Control elements
Fig. 17: Control elements
No. Function
1 LED
• On – continuous light set (only possible with remote control)
- Flashes fast - detection in test mode
• Flashes 3 times - detection in standard and normal operation
• Flickers: incoming IR signals (remote control)
2 Lens
3 Trim potentiometer for switch-off delay, short-time pulse
4 Trim potentiometer for brightness value, test/standard operation
5 Screw for dismantling safety
8.2 Standard operation
Fig. 18: Standard operation
Lighting during advancing twilight remains switched on for 3 minutes after the last detection.
After activating the mains supply voltage the device remains in test mode for 10 minutes (see
chapter "Activation test").
11
2
3
4
5
T/ S

Operating Instructions
Busch-Wächter®Operation
Operating Instructions | 1473-1-8102 — 17 —
8.3 Standard operation (time- and brightness dependent)
Fig. 19: Normal operation
Set the values for the brightness limit value and the switch-off delay (on period of the light after the last
detection).
Short-time pulse for activating the staircase light timer switches or door bells.
Icon Function
Switching during all brightness levels
Switching during advancing twilight
Switching during darkness
Short-time pulse
Pos:43 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/2. Ebene/M - O/Neb enstellenbetrieb @ 18\ mod_1308568178899_15. docx @ 107029 @ 223 @ 1
8.4 Auxiliary post operation
Pos: 44 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Nebenst ellenbetreib/W aechter/Nebenstellen betrieb - 68476867 -- 220-280M asterLINE @ 28\mod_13475146 57878_15.docx @ 233191 @ 1111 @ 1
8.4.1 Operation with extension unit push-button
Aside from the movement detector being triggered by the infrared radiation in the detection range, manual
operation is possible via an extension unit push-button.
For example, when an exit is not within the detection range of the movement detector, the extension unit push-
button can be used. The lighting can there be switched on or off manually with the push-button.
Fig. 20: Operation with extension unit push-button
• When operating with an extension unit push-button, the lighting for the set operating mode is switched on.
Pos:45 /#Neustruktur#/Online-Dokumentation(+KNX)/Steuermodule- Online-Dokumentation(--> Für alleDokumente<--)/++++++++++++Seitenumbruch + +++++++++++ @ 9\mod_12688 98668093_0.doc x@ 52149 @ 212 22 @ 1
T/ S
0
315
5
1min
10
sek

Operating Instructions
Busch-Wächter®Remote control
Operating Instructions | 1473-1-8102 — 18 —
Pos:46 /#Neustruktur#/Online-Dokumentation(+KNX)/Überschriften (-->Für alle Dokumente<--)/1. Ebene/G - L/ Handsender @ 24\mod_1338471401020 _15.docx @ 214714 @ 21222 @ 1
9 Remote control
Pos: 47 /#Neustruktur #/Online-Dokumenta tion (+KNX)/Sonstige/ Handsender/W aechter/Handsender - 6847- 6867 @ 24\mod_1338471592 389_15.docx @ 214731 @ 22222 @ 1
9.1 Control elements of the remote control
Fig. 21: Control elements
No. Function
1 Resetting the switch-on brightness to the settings of the potentiometers on the Busch-Watchdog.
- Press the button for at least 1 second.
2 The current brightness is set as switch-on brightness.
- Press the button for at least 1 second.
3 Deactivation of presence simulation.
4 Presence simulation activation.
– Continuous light between twilight and 22:30 p.m. CET or 23:30 CEST. Followed by movement detection.
5 Light deactivation for 4 hours.
– No detection of movement.
6 Light activation for 4 hours.
– No detection of movement.
7 Resetting to automatic movement detection.
The sensitivity of the movement sensors can be adjusted to surroundings which are particularly
restless or free of movement.
9.2 Technical data of the remote control
Designation Value
Operating voltage: 3 V DC
Battery type: CR 2025
Battery life: Approximately 2 years
Coverage: Maximum of 6 m
Protection type: IP 40
Operating temperature: 0°C … 45°C
2
4
6
7
1
3
5

Operating Instructions
Busch-Wächter®Remote control
Operating Instructions | 1473-1-8102 — 19 —
9.3 Commissioning of remote control
Fig. 22: Removing the protective foil from the battery
Remove the protective foil from the battery before commissioning.
Fig. 23: Programming the remote control
• Press the "AUTO" button on the remote control for at least 3 seconds within the period of 10 minutes after
activating the power on the Busch-Watchdog.
- The Busch-Watchdog must be de-energized beforehand for at least 30 seconds.
- The remote control will then automatically connect itself to the Busch-Watchdog, and the Busch-
Watchdog will flash if the reception is correct.
- Repeat these steps to program a maximum of 9 additional remote controls.
9.4 Battery change of remote control
Fig. 24: Changing the battery
1. Pull the battery holder out of the remote control.
2. Insert a new battery of type 2025.
- The plus pole of the battery (+) must be on top.
3. Push the battery holder back into the device.
=== Ende der Liste für TextmarkeCon tent ===
+
CR 2025

Operating Instructions
Busch-Wächter®
1473-1-8102 | Rev. 01 | 11.2012
Pos:49 /#Neustruktur#/Online-Dokumentation(+KNX)/Rückseiten(-->Für alle Dokumente<--)/Rückseite- Busch-Jaeger - Allgemein @ 28\mod_134 7009779995_15.doc x @ 232282 @ @ 1
A
member of the ABB Group
Busch-Jaeger Elektro GmbH
PO box
58505 Lüdenscheid
Freisenbergstraße 2
58513 Lüdenscheid
Germany
www.BUSCH-JAEGER.com
Central sales service:
Phone: +49 (0) 2351 956-1600
Fax: +49 (0) 2351 956-1700
Notice
We reserve the right to at all times make
technical changes as well as changes to the
contents of this document without prior notice.
The detailed specifications agreed to at the time
of ordering apply to all orders. ABB accepts no
responsibility for possible errors or
incompleteness in this document.
We reserve all rights to this document and the
topics and illustrations contained therein. The
document and its contents, or extracts thereof,
must not be reproduced, transmitted or reused by
third parties without prior written consent by ABB.
Copyright© 2012 Busch-Jaeger Elektro GmbH
A
ll rights reserved
=== Ende der Liste für TextmarkeBac kcover ===
This manual suits for next models
1
Table of contents
Popular Security Sensor manuals by other brands

IFM Electronic
IFM Electronic OGE3 Series operating instructions

ESP Safety
ESP Safety IPES-IR/UV operating manual

Larson Electronics
Larson Electronics SLEDB-110V-30C-XMS quick start guide

Niko
Niko 351-25456 quick start guide

bolid
bolid IP 212-31 DIP-31 Operation manual

GE
GE EV435AM-AD Series installation manual