Fixed gas connection
The appliance is supplied with the most common
parts required to connect the appliance to a fixed
gas connected.
Additional spares can be supplied by calling
the Customer Helpline on 0345 257 7271.
If the appliance is to be connected to the gas inlet
using a fixed gas connection, the following must
be observed:
• The nut on the gas manifold must always
remain in a fixed position. Only rotate mating
parts.
• Use the correct size tools for all connections.
• Only the supplied seals should be used. Do
not use plumbing seals to make connections.
Alternative supplies
The appliance is equipped for connection in the
country of manufacture. This is indicated on the
rating plate of the appliance.
If the appliance is to be used in another country,
the alternative connections shown in figure 3
may be used. You must only use the alternative
connections designed for the selected supply.
The connection of the appliance should be
performed in accordance with local and
international standards and applicable regulations.
You can find the information related to appropriate
gas types and appropriate gas injectors in
the Technical Specifications of the Operating
Instructions.
If the gas pressure used is different to the values
in the Technical Specifications or the gas supply
pressure is not stable, the gas inlet requires a
pressure regulator.
You must contact your authorised service agent to
make these changes.
Flexible hose connection
If the appliance is to be connected to the gas
inlet with a flexible hose, the following must be
observed:
• The flexible hose must be secured with a pipe
collar.
• The flexible hose must not exceed 1.5m in
length and should be kept as short as possible.
• Inspect the flexible hose prior to installation and
annually for signs of damage including ruptures,
bends or folds. Do not use damaged hoses.
• Make sure the flexible hose is located away
from sharp objects.
WARNING – Do not use naked flames or sources
of ignition to perform leak tests.
• All connections including the flexible hose must
be leak tested using a suitable fluid.
IMPORTANT – Make sure all metal connections
are free from rust. Rust may pose a potential
source of ignition.
Installation Customer Helpline 0345 257 7271
Gas connection
Figure 3
5