CAUTION:
Verify power is OFF to swi tch
be f o re proceeding.
IMP O R TANT NOTES
TOGGLE SWITCH TECHNICAL SPEC.
TOGGLE SWITCH STYLE:
STANDARD 2 WAY SWITCH.
RATED AT 10AX250V~ AC ONLY.
1. Bef o re commencing work, isolate the mains power
supp ly a n d remove the fuse in the fusebox or switch
o t he c i rcuit breaker in the consumer unit.
6. Turn power back on.
2. If u nit is t o b e use d as a replacement for an existing
pr oduct, remove existing unitfro m its locatio n a n d
disco n n ectt h e w i r i n g .
5. To re d uce the risk of discolouration ortarnishing, avoid
installation onwetplaster.
1GANG 2 WAY 10AX AND TOGGLE SWITCH
2GANG 2 WAY 10AX AND TOGGLE SWITCH
3 GANG 2 WAY 10AX AND TOGGLE SWITCH
INSTALL ATION
BUSTERANDPUNCH . C O M
ELECTRICIT Y
1 G , 2 G, 3G & 4G SWITCH
SKU# AUZ-TO-CO-1G-XX-A**, AUZ-TO-CO-2G-XX-A**,
AUZ-TO-CO-3G-XX-A**, AUZ-TO-CO-4G-XX-A* *
4 GANG 2 WAY 10AX AND TOGGLE SWITCH
Note: To ensure your toggles operate in the same orientation for on and
off for the top and bottom rows, you need to wire your top row of
toggles in reverse order to the bottom row. This means your Live will
now be wired into L2 and your Neutral will be wired into L1.
i) Please ensure screws are sufficiently tight to support the
product but please do not over tighten as this may cause
some deformationto the plate or damage the screw.
ii) Do NOT use a standard screw driver to tighten the coin
caps. This may damage the cap and is not covered under
warranty. Plastic coincap tool must be used by hand only.
Use a c ross head electric
or ma nual s c rewdriverto
fit the special countersunk
scr ews u nti l tight.
3.
4a.
4a.
By hand, s c rew the coin
caps int o theend of th e
scr ews. Use the plastic coin
cap toolto fully ti g h ten the
co in c a p s i).
4b.
4b.
Co n n ectt h e w i res as shown in appropriat e w i r i n g
diagrams. Us e g r een/yellow s leeving on earth conductors
th a t a re n o t insul a t e d . E nsure terminals are pro perly
ti g h ten e d and n o b a re wire is visable. Push back unit into
moulding box making sure conductors are nott rapped .
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L
L1 L2
L
Please readbefore installing.
All wiring and installation must adhere to the latest
local and national wiring rules - e.g.AS/NZS 3000 in
Australia & New Zealand;
This product is suitable for indoor use only.
Must be installed by a licensed electrician;
Do not exceed the rated power input
specification;
1.
2.
3.
4.
APPROVAL NO. SAA-171697-EA
WARNING: The two mounting screws on the
faceplate must be well tightend to maintain the
earthing continuity. Check their earthing continuity by
multimeter before screw on the decorative cap. The
resistance between the two mounting screws must
not exceed 0.1 Ω.
TO EARTH
TERMINAL
IN BOX
TO EARTH
TERMINAL
IN BOX
NOTE: The plate must be earthed at the earth point