manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BVF
  6. •
  7. Thermostat
  8. •
  9. BVF Heato9 User manual

BVF Heato9 User manual

Other BVF Thermostat manuals

BVF 23-FA User manual

BVF

BVF 23-FA User manual

BVF L-1 User manual

BVF

BVF L-1 User manual

BVF 24-F User manual

BVF

BVF 24-F User manual

BVF SYME model-E User manual

BVF

BVF SYME model-E User manual

BVF 23-FA User manual

BVF

BVF 23-FA User manual

BVF 23-FA User manual

BVF

BVF 23-FA User manual

BVF Heato8 User manual

BVF

BVF Heato8 User manual

BVF 601 User manual

BVF

BVF 601 User manual

BVF 24-F User manual

BVF

BVF 24-F User manual

Popular Thermostat manuals by other brands

Full Gauge TIC-17C product manual

Full Gauge

Full Gauge TIC-17C product manual

Imit Chronomix S manual

Imit

Imit Chronomix S manual

ChiliTec ST-35 ana instruction manual

ChiliTec

ChiliTec ST-35 ana instruction manual

Salus VS05 Installer's/user's manual

Salus

Salus VS05 Installer's/user's manual

Azel D-500 user guide

Azel

Azel D-500 user guide

Honeywell Chronotherm III owner's manual

Honeywell

Honeywell Chronotherm III owner's manual

Charmeg MP-R user manual

Charmeg

Charmeg MP-R user manual

dixell WING XW40LS Installing and operating instructions

dixell

dixell WING XW40LS Installing and operating instructions

Network Thermostat NetX X7C-WIFI Installation and programming manual

Network Thermostat

Network Thermostat NetX X7C-WIFI Installation and programming manual

Radio Thermostat CT80 Operation guide

Radio Thermostat

Radio Thermostat CT80 Operation guide

HAI Omnistat RC-120 installation manual

HAI

HAI Omnistat RC-120 installation manual

Lennox iComfort E30 Installation and setup guide

Lennox

Lennox iComfort E30 Installation and setup guide

Lux Products PSD011Ba Installation and operating instructions

Lux Products

Lux Products PSD011Ba Installation and operating instructions

Computherm Q20 operating instructions

Computherm

Computherm Q20 operating instructions

Heatmiser neoStat user manual

Heatmiser

Heatmiser neoStat user manual

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

Mars

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

LUX LP0511D user manual

LUX

LUX LP0511D user manual

Saswell SAS920XWHB-7-S-RF User manual and warranty card

Saswell

Saswell SAS920XWHB-7-S-RF User manual and warranty card

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

User manual
www.bvfheating.com
BVF Heato9
Programmable smart thermostat,
Heato Box compatible for online access
SPECIFICATION
Operating voltage: 230V AC, 50/60 Hz
Capacity: 3600W/16A
Standby consumption: 0.5W
Display: LCD White backlight
External Sensor: NTC 10kΩ @ 25°C
IP protection rating: IP 30
Housing: White ABS to UL94-5 re
standard
Temperature settings: 5°C–80°C, 0.5°C
Accuracy: ± 0.5°C
PRG options: 5+1+1, four cycles each day
Housing dimensions: 86 mm × 86 mm × 16 mm
Relay inst. dimensions: Ø 65 mm diameter, standard
Radio frequency: 433 MHz
Channel selection: ID Study function
To pair it with Heato Box, please follow the steps in the Heato Box user
manual.
SETTING COMFORT MODE AND ENERGY-SAVING MODE
Switch between modes using the button.
1. Choosing the Comfort Mode you may assing temperature using or buttons.
2. Choosing the Energy-saving Mode you may assing temperature using or buttons.
Day indicator
Comfort Mode
Increase temperature
Clock
Temp. display
RF signal
Key lock on
Heating icon
Period Icons
Energy-saving Mode
Decrease temperature
PRG Mode
Modes & Parameter
Power On / O
CLOCK & 5+1+1 PRG SETTING
PRG function allows you to set dierent temperatures throughout the day. For example, you may want the home warm in the morning, cooler when you leave it for
the day, and then warmer in the evening when you return. The thermostat oers 5+1+1 programming option, four dierent temperature levels for each day. Default
comfort levels are pre-programmed; still you can change them easily with the following method:
Press and hold button for 5 seconds,
1. press and to adjust the clock (min-hour-weekday), each press of will go into the next setting,
2. after the clock adjustment, press to change the 5+1+1 mode. By pressing and you can set the desired time and temperature of each period.
(Weekday- period- time- temp.) Each press of the button goes into the next item setting.
User manual
www.bvfheating.com
KEY-LOCK FUNCTION
In order to avoid unauthorised access (hotels, public areas, child room) you can activate the key lock function from parameter settings page 12. To unlock your device
long press the and buttons for ~5 seconds.
DEFAULT VALUES
PARAMETER SETTINGS
WIRING DIAGRAM & INSTALLATION
During the power o mode, to access or modify parameter settings, please press and hold the and buttons simultaneously for ~8 seconds until the MENU
appears showing 01 which is menu 1. Each press of the button goes to the next MENU.
Period Wake up 1 Leave Home 2 Return Home 3 Sleep 4
Time Temp. Time Temp. Time Temp. Time Temp.
1-5 (Mon.-Fri.) 7:00 22°C 8:30 19°C 17:00 22°C 22:00 19°C
6 (Sat.) 8:00 22°C 8:30 22°C 17:00 22°C 22:00 19°C
7 (Sun.) 8:00 22°C 8:30 22°C 17:00 22°C 22:00 19°C
Menü Description Range Default
01 Temp. Oset -8°C ~ 8°C 0
02 Set Point Max. 5°C ~ 80°C 35°C
03 Set Point Min. 5°C ~ 80°C 5°C
04 Sensor Select
ROOM
SURFACE
Room + Surface
05 Frost Protection Temp. 5°C ~15°C 5°C
06 Surface Temp. Display Read Only
07 High Temp. Protection 10°C ~ 80°C 32°C
11 Reset rE(Yes)
12 Key lock 0 - o, 1 - on 0
13 Master ID address Read Only
14 OWD function ON/OFF Select 0 - o, 1 - on 0
15 OWD Detect Time Select 2 ~ 30 mins 15 mins
16 OWD Drop Temp. Select (within detect time) 2 / 3 / 4°C 2°C
17 OWD Delay time select (Return to previous working status) 10 ~ 60 mins 30 mins
18 The temp. di to exit high protection mode 1°C ~ 3°C 1°C
19 External sensor temp. oset -8°C ~ 8°C 0
20 Energy optimisation 1: electric radiator 3: ceiling heating
2: heating panel 4: oor heating 2
21 Brightness (Standby Mode) 0 - 100% 5%
22 Software version Read Only
v1.1 EN (08.02.2019)
EXTERNAL SENSOR
230V/AC16A