HOW TO ARM YOUR SECURITY SYSTEM
ToArmthesecuritysystem,closealloftheprotecteddoorsandwindows.Thegreen"READY"
light on the keypad control will be illuminated when all of the protected zones and sensors are
secure. If any of the zones are bypassed, a sensor in that zone can be violated without
affecting the "READY" light. The security system will not arm if the "READY" light is not
illuminated unless "FORCE ARMING" has been enabled (see "FORCE ARMING" page 4).
With the "READY" light on, you may arm the security system with your Master Code or one of
the auxiliary codes. Each time a key is pressed on the keypad control, a short tone (beep) will
sound. If the keypad beeps three times after a code entry, it is an indication that the code has
not been accepted. Press the [#] key (reset) and re-enter a valid code. If the keypad control
beeps continuously after code entry, it is an indication that; (1) the "POWER" light is off,
meaning there is no AC power to your system; (2) a faulted fire zone; or (3) a faulted phone
monitor. The keypad sounder can be silenced by re-entering your four digit code. If the
"POWER" light is off, you should restore power to the system if possible. If the “Ready” light
is flashing, a telephone line fault has been detected. If you are unable to correct the above
conditions, you should contact the installing company listed on page 1 of this booklet for
service. When the security system has accepted a valid code, the red "ARMED" light will
illuminate indicating that the system has been turned on. If you choose to leave the protected
area, you must exit through a designated exit door within the exit delay time noted on page 1.
If you choose to stay within the protected area, insure that all interior zones which may be
tripped by your movement are bypassed.
NOTE: If the exit door is open when the exit delay expires, the siren will sound, and the entry
delay will begin. If a valid code is not entered prior to the expiration of the entry delay, an
alarm report will be transmitted to the monitoring station if the system is monitored. Entering
avalidcodeduring theentrydelaywill disarmthesystem, silencethesiren, andkeepan alarm
report from being transmitted.
HOW TO DISARM YOUR SECURITY SYSTEM
Whenyou enterthe protectedarea throughone ofthe designatedentry/exitdoors,the keypad
control will sound a continuous tone (beep) for the duration of the entry delay time, or until you
entera validcode.Afteravalidcodehas beenentered, thered "ARMED"light willturnoff,and
thetone will stop.The security systemis nowDISARMED.If avalid codeis not enteredbefore
the end of the entry delay time, an alarm will occur. (NOTE: IF THE RED "ARMED" LIGHT IS
FLASHING DURING THE ENTRY DELAY, THE ALARM SYSTEM HAS BEEN ACTIVATED
IN YOUR ABSENCE. LEAVE THE BUILDING IMMEDIATELY AND CALL YOUR ALARM
COMPANY AND/OR THE POLICE FROM A SAFE LOCATION.)
HOW TO BYPASS ZONES
Whenzones areopen orunsecured, theircorresponding LEDswill flash.To bypassany ofthe
zones, press [U], zone number(s) to be bypassed, and [U]. When bypassed, corresponding
zone LEDs will be on steady. Zones cannot be bypassed while the control is in the armed
state. Upon disarming, all bypassed zones will be unbypassed. As bypassed zones are not
protected, the bypass procedure should only be given to authorized persons.
QUICK-ARM FEATURE
Ifchecked,yoursecuritysystemhasa"QUICKARM"codeprogrammed.Thisfeaturewillallow
you to arm the security system by pressing one, pre-designated key on the keypad control.
This "QUICK ARM" code is for ARMING ONLY, and will not disarm the security system. This
makesitideal foramaidcode, babysittercode,etc. Thiscodecanonlybeprogrammedand/or
changed by your installing company.