manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cajun Kooling
  6. •
  7. Air Conditioner
  8. •
  9. Cajun Kooling CK3000-S User manual

Cajun Kooling CK3000-S User manual

Other Cajun Kooling Air Conditioner manuals

Cajun Kooling CK4500 User manual

Cajun Kooling

Cajun Kooling CK4500 User manual

Cajun Kooling CK4500 User manual

Cajun Kooling

Cajun Kooling CK4500 User manual

Cajun Kooling CK4500 User manual

Cajun Kooling

Cajun Kooling CK4500 User manual

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

InstructionManualEvaporativeAirCoolerCK3000-S-Portable--EasytoOperate--LowMaintenance-- Energy Efficient -
ImportantSafetyInstructionsREADANDSAVETHESEIMPORTANTSAFETYINSTRUCTIONSBEFOREUSINGTHISUNITWHENUSINGELECTRICALAPPLIANCES,BASICPRECAUTIONSSHOULDALWAYSBEFOLLOWEDTOREDUCETHERISKOFFIRE,ELECTRICALSHOCKANDINJUURYTOPERSONS,INCLUDINGTHEFOLLOWING:_____________________________________________________________________ModelType:(CircleOne)-CK4500-S-CK4700-CK3000-S-CK8200-CK18000SerialNumber:(listedonsilverstickeronsideofunit:ex.Ck300009090909)______________________________Attention!Thefollowingisimportantinformationregardingyourwarranty.Pleasereadbeforeopeningandoperatingyourunit.WarrantyWelcometoyournewevaporativeaircooler.Afterpurchasingthisproduct,pleasefillouttheformbelow,andmailittotheCajunKooling.addresswithin14daysofpurchase.Thiswillensureyoua2-yearwarrantyonallmechanicalpartsnotincludinglabor.Pleasecheckitemsuponopeningandexamineforanypossibledamage,inordertovalidateyourwarranty.PleasecutondottedlineandmailintotheCajunKoolingaddress.Yourmailedinwarrantywillbevalidatedaccordingtothedateonourcopyofyourreceiptfrompurchase.CajunKoolingLALLC.112ThruwayParkBroussard,LA705181-844-819-3557--------------------------------------------------------------------------------------------CustomerName:CustomerAddress:_____________________________________________________________________Tel.Number:Dateofpurchaseanddistributorname:1. The unit should always be placed on a firm level and flat surface, and at least 6-10 inches away from the wall.2. The unit should not be used in a small, enclosed room while using the COOLING function without proper ventilation for long periods of time. The air could become saturated and leave condensation on the walls. Leave a door/window partially open when used indoors.3. Before using the unit, check the cord for any signs of damage. DO NOT use the unit if the cord has been damaged. Plug into 120volt, 15amp, 60Hz circuit to avoid fire or shock hazards, CK3000-S cannot be connected to GFCI outlet .4. The appliance should be unplugged and emptied when not being used for long periods of time. Shut off and unplug the unit before moving. DO NOT tilt while the unit is in operation. Plug and unplug with dry hands, and never unplug by tugging on cord.5. The COOLING (snowflake) feature will only operate when water is in the reservoir. Otherwise, the unit will run as a FAN only. First, fill with water. Then plug in, and then turn on your unit. The cooling will automatically begin and you will see a snowflake light up on the panel. If there is no water in the unit, the cooling will automatically shut off and a the snowflake will keep peeping, indicating that it needs more water. If there is no water, it will not harm the motor and will work properly as a regular fan. This is a safety feature.6. This unit requires some maintenance; refer to cleaning instructions for details.7. This unit is designed for outdoors in high humid states. It can be used indoors in open spaces for short periods of time. There is no compressor in the unit and will not act as an air conditioner. It is not recommended as a daily household cooling unit, because of the moisture production in small areas can be harmful.8. Do not insert any object inside the unit without proper care. Only water should be added. Refer to cleaning instructions for details.9. Do not attempt to repair or adjust any electrical or mechanical functions without consulting Cajun Kooling Support first. Doing so will void the warranty.10. If you plan to not use the unit for long periods of time, drain out all of the water from the reservoir to ensure lifelong durability. Then turn the unit on and run as the FAN function only, for approx. 30 mins. This ensures that the inside of the unit will be completely dry before storing.11. Ice may be added from the front flap or side opening for extra cooling
andcomfortableair.Nomistwillbeproduced.Afterapprox.8-12hours,thewaterreservoirwillbecompletelyevaporatedintotheairandwillneedtoberefilled.HowItWorks:Thisunitisaportablefan,aswellsanevaporativeaircooler.Whenusingthecoolingfunction,thewaterinsidetheunitwillbepumpedthroughoutpipesinsideandwillbedispersedontothecoolingpads.Themotionofthefanwilldragairintotheairintakeareas,whichwillthenpassthroughthecoolingpads.ThemovementofthewindoverthemoisturewillevaporateandcreatenaturallycoolInteriorStructureExterior Structure filtervertical auto swing louvershorizontal adjustable louversmanual water fillcontrol panelside panel(air intake)water level indicatorswivel casters lockingswivel casters NON-lockingwater tankRemote control1.“ ”ON/OFF2.“ ”“ ”“ ” Increase speeds3.“ ”“ ”“ ” Reduce speeds4.“ ”Cooling mode5.“ ”Fan mode6.“ ”Non functional for this model 7.“ ”Auto Swing mode
Troubleshooting:PleasecallCajunKoolingSupportbeforealteringorreplacinganyparts.Somepartsmaynotneedfullreplacementandcanbeservicedbyatechnician.1-844-819-3557swing motor swing motor support motor bracket fan blades louver bracket horizontal louver manual water inlet drain cap water hoseside filterside louvercooling pad supportcooling padfilterback panel(air intake)motorcontrol panel boxelectrical control boardcontrol paneltop coverwater distributorside cooling padcasterswater sensorsubmersible pumpwater tankside cooling pad supportside cooling padProblemPossibleCauseSolutionCannotturnontheunit1.Thepowersupplyisnotconnected2.ON/OFFbuttondoesnotwork3. Fuse shortage4.Voltageistoolow1.Checkthepowersupply2.Replacethecontrolpanel3.Checkthephasewire (spare fuse available in the box)4.CheckthevoltagesupplyThefuseshortsoften1.Thewaterpumphasshutoff3.Motorofthe“swing”functionisbroken1.Replacethewaterpump3.Replacethemotorforthe“swing”WaterLeakagefromexternalpartsorspittingwater1.Themachineisnotwellbalanced2.Waterreservoirisleaking3.Drainisleaking4.Waterlevelinletisleaking5.Waterlevelistoohigh6.Internalpipesfordistributionisbroken or moved7.Coolingpadsdirty8. Side opening is not fully closed.1.Placeonabalancedsurfaceandgivetimeforexcesswatertodryup2.Checkforanyholesorcracksonthetank3.Sealthedrainproperlyanddonotovertighten4.Checkforcracksordamagesofthewaterinletflap5.DrainsomewateranddonotfillpastHighandcheckthattheinternalfloatisproperlypositioned6.Openunitfromthebackandcheckthepipesforanyleaks and disconnections7.Removeandproperlycleanthecoolingpads8. Tuck the side opening under and into the bracket9. foam product been used clean the cooling padsMakingnoise1.Fanbladesaredirty,warped,orbroken2. Replace the motorBuild-upisblockingtheairflow3.Waterwasfilledtoohighandreachedthefanblades4.1. Replace the fan blade2. Replace the motorCleantheunitfromtheinsideoutandallofthecoolingpadsandscreens3.Drainsomewaterandallowfordrying4.Nowindsupplyortheairflowistoolow1.Coolingpadsorscreensareclogged2.Controlpanelisbroken3.Remotecontrolisbroken4.Fanisnotturningon5.Shortageinthephasewire1.Cleanorreplacethecoolingpadsorscreens2.Replacethecontrolpanel3.Checkbatteriesorreplacetheremote4.Checkthemotorfrominsideoftheunit5.CheckthephasewireNoCooling1.Shortageofwaterinthereservoir2.Waterpumpbroken3.“Cooling”buttononthepanelisbroken or turned off4.Remotecontrolbroken1.Addwatertoreservoirandmakesure“snowflake”stayslituponcontrolpanel2.Repairthewaterpump3.Checkthepaneland/orreplace4.CheckthebatteriesorreplaceremoteWaterreservoirorscreenshavewhitebuildup1.Mineralsubstanceinthewateristoohigh2.Improperchemicalswereaddedtotheunit1.Cleanmorefrequently2.Donotaddanychemicaltothewaterortotheunit4. Power strip is too strong or too weak4. Use a proper outlet for machine9. spitting water6. Plug unit into a proper plug with more voltage6. Outlet is too weak for amperage5. pump sensor5. Check the pump sensor if its floating
Control PanelTroubleshooting:Electrical Wiring DiagramInstallingTheUnit:
swingwater pump
blueswingmotorwaterpumpmotorconnect to the signal wire High speed Low speed
yellowwhite
brownNL
fan-μF/500V
UVUVAC220V~240VUltra-low speedMedium speed CleaningandMaintenance:1.TheDryingProcess:Forlongerlifetimeofyourevaporativeaircooler,afterusingtheunit,itisrecommendedtoTURNOFFthecoolingfunction(snowflakebutton)andruntheunitasaFANonlyforapproximately30mins.Thishelpstodryoutthecoolingpadsandavoidmildew.Theremainingwatercanbekeptinthereservoirfor3moredays,butshouldbechangedatleastonceaweek.Ifstoringforlongerthanoneweek,drainthewaterfromthereservoirusingthedrainvalveatthebottomoftheunit,andthencompletethedryingprocess.2.FortheAutomaticDrying:thetimercanbeusedasaconvenienceforyoutodryyourunitwithouthavingtooccupyit.SimplyturnthesnowflakebuttonOFF,keepthefanrunning,pressthetimerbuttononforonehour,andthefanwilldryandshutdownitselfafteronehour.3.Thereservoircanhandle2oz.ofbleachinatleast32-gallonsofwatertorefreshtheinterior.DONOTputanyothercleaningorfoamingproductsintothemachine,becauseitwillfoamupthewaterandoverflowyourunit.Donotdothismorethanonceaweek.4.Theblackscreensprotectingyourcoolingpadswillcollectdustandshouldbecheckedatleastonceaweekwhenusingfrequently.Pullthemoutandsimplyhosethemofforwipedownwithawetragandre-insert.Toavoidbuildup,DONOTputchemicalsonthescreens.Thescreensshouldbetransparentandyoushouldbeabletoseecompletelythroughthemaftertheyhavebeencleaned.Thisensurescompleteairintake.5.Cleaningthecoolingpads:makesurethecoolingpadsaredryandthemachineisunplugged.Useascrewdrivertoremovethebackpaneloftheunitandthecoolingpadscaneasilyslideinandout.Rinsesoftlywithahosethroughonesideonlyonlowpressureanddonotuseanychemicals.Atanangle,youshouldbeabletoseelightthoughtheholesonceithasbeenfullycleaned.Re-insertthepadsgentlyandputthebackpanelbackintoplaceandputthescrewsbackintoplace.88 This CAJUN KOOLING the CK3000-S unit is factory tested and ready to use. make sure the unit is placed on flat level surface and the front casters are locked to prevent inadvertent movement, please follow the instruction below 1.Stand your box up and remove the box from the unit by lifting it over the top. Make sure that all parts are intact and correctly assembled.2.You may begin filling water through the water inlet flap using regular tap water. There is a water level in the front of your unit, located on the reservoir. Be sure not to fill past the “H”, HIGH, level. You will not see the water until it reaches half of the tank on “L”, low, but this level may not need to be reached for your preference. Filling at half of the tank will last at least 4 hours of run time.3.Plug in the power cord to a safe outlet, and begin using your fan by pressing the Power button. Choose your suitable speed for your unit and begin enjoying.2. AUTO WIND MODE3. COOLING MODE/ WATER PUMP ON/OFF4. WIND SPEED ADJUSTMENT5. LCD DISPLAY SCREEN1. ON/OFF6. TOUCH SCREEN LOCK7. OSCULATION (SWING) MODE8. MACHINE SHUT DOWN TIMER9. REMOTE CONTROL SIGNAL