Parame ter Table
、
Evaporative air cooler
V
Conditions of Using
、
IV
Scope of Application
、
9
Evaporative air cooler
Fault phenomenon Possible cause
1、Cannot operate
this machine
Solution
XIV、Ordinary fault and solution
3、Water leakage
4、Noise too loud
1.Replace another fan
2.Replace another motor
3.Clean out the obstacle
6、No cooling
1.The content of mineral substance is
too high in water supply
1.Increase the times of water drainage
and have a water soft treatment
2、Fuse often
break down
1.Fan become dirty, transform or
break down
2.Motor break down
3.Some sundries block the air inlet
or air outlet
5、No wind supply or
airflow too low
1.Cooling pads or dust proof nets are
blocking
2.Control panel break down
3.Controller break down
4.Fan does not work
5.Motor phase shortage
1.Clean or replace the cooling pads or
dust proof nets
2.Replace another control panel
3.Replace another controller
4.Check over the motor
5.Check over the phase wire
1.Water in the container shortage
2.Water level control system
3.Submersible pump break down
4.“cooling” button does not work
5.Controller break down
1.Add water into water container
2.Repair water level sensor
3.Replace another submersible pump
Replace another control panel
5.Replace another controller
4.
7、Water container and
dust proof net appear
white precipitation
Air cooler has a lot of excellent advantages like cooling, humidification,
purification, ventilation, saving energy. This product suitable for the place is
open and ventilation .
1.Processing industry: electronics, electroplate, shoemaking, textile
printing, plastic, garment, packing, foodstuff.
2.Manufacturing industry: spinning, machinery, ceramics, fine chemistry,
metallurgy, glass, hardware, leather.
3.Hospital, clinic, school, waiting room, cyber cafe, store, supermarket,
washing room.
4.Public: kitchen, food market, big entertainment center, underground
parking, bus station.
5.Farm: green house, flower, poultry, livestock.
6.If some place have strict humidity require, the equipments should depend
on the engineering design.
1.Ambient temperature:25℃~45℃
2.Relative humidity: ≤90%
3.Water supply should make softening treatment,
0℃<temperature of water supply<45℃.
Pressure of water supply:0.15~0.6MPa
4.Deviation of voltage can not more than ±10% of rated voltage;
5.No corrosive gas;
6.No inflammable and explosive gas or dust.
Air Outlet Dimension(mm)
Current
Water Consumption
Airflow
Machine Size (mm)
Water Container
Rang of Air Supply (m)
Model
Lowest Noise
Motor protection grade
Voltage/Frequently
Net Weight
Power
110V/60Hz
CK4500
600×640
3
7600m/h
3~6L/h
0.4kW
3.5A
65dB
12x3
38kg
Axial /3 speeds
Type of Fan
1.The power supply is not connected
2.“ON/OFF”button does not work
3.phase shortage
4.voltage is too low
1.Check over the power supply
2.Replace another control panel
3.Check over the phase wire
4.Check over the voltage supply
1.Water pump break down
2.Drainage pump break down
3.Motor of wind swing break down
1.Replace another water pump
2.Replace another drainage pump
3.Replace another motor of wind swing
1.Place this machine to balance
2.Repair the water container
3.Replace the water drainage device
4.Replace the water inlet device
5.Adjust the water float valve position
6.Check over the water distributive
pipe device
7.Clean the cooling pads
1.This machine place not balance
2.Water container leakage
3.Drainage device break down.
4.Water inlet device break down.
5.Water level too high
6.Water distributive pipe device
break down
7.Cooling pads dirty
Machine protection grade
IPX4
910x480x1380
IPX4