PRODUCT SPECS:
VoltageInput:110V
Maximumoutputcurrent:15AM,Fuse:AC110V15AM
Remotecontroldistance:Openspace>150Feet(50meters)
MaximumGateweight:1000LBS
MaximumGatelength:22FEET
WARNING
ToreducetheriskofINJURYorDEATH:
Neverletchildrenoperateorplaywithgatecontroloraroundgate,keep
remotecontrolawayfromchildren.
ALWAYSkeeppeopleandobjectsawayfromgate.NOONESHOULDCROSS
THEPATHOFMOVINGGATE.
Testgateoperatormonthly.ThegateMUSTreverseincontactwitharigid
objectofreversewhen anobjectactivatesthe noncontactsensors.After
adjustingtheforceorlimitoftravel,resetgateoperator.Failuretoadjust
and reset the gate operator properly can increase the risk of INJURY or
DEATH.
UsetheemergencyreleaseONLYwhengateisnotmoving.
KEEPGATEPROPERLYMAINTAINED.Readowner’smanual.Haveacertified
servicepersontomakerepairsorinstalloperatorhardware.
The entrance is for vehicles ONLY. Pedestrians MUST use separate
entrance.
SAVETHESEINSTRUCTIONS.
3000
50

2
3
Installation of Base
1. Layoutpositionof6Anchorsbymeasuringclearancebetweenanchorsand
insideedgeofgate.Figure1
2. Installundergroundconduitsinareaforconduits.Figure2
Figure1 Figure2
3
Installation of Base
1. Lay out position of 4 Anchors by measuring clearance between
anchors and inside edge of gate. Figure 1
2. Install underground conduits in area for conduits. Figure 2

3
4
Installation Barrier distance
Figure3
Figure4

4
5
Position Of Gate and Operator
Twooptionsforchainconnections:
Figure5 RearMount
Figure6 FrontMount

5
6
Welding Bracket of Chain
Figure 7
Correct connection of chain
Figure 8
Figure 8. Follow the correct way to install chain. Incorrect installation will cause
malfunctionofoperatorandpotentialdamages.

6
7
Power Connection
Figure9
1. MUSTuseULprovedpowerwires,powerwiresMUSThaveminimumcapacity
for25Amcurrent.
2. AlloperatorsMUSTbeproperlygroundedinordertopreventelectricalcharge.
Mustusededicatedcircuitforpowersupply.
3. Whenpowerisconnected,turnoperatorpowerswitchtoONposition.

7
8
EMERGENCY RELEASE
Figure10
A. EmergencyReleaseofgate
1. Disconnectpower.
2. PushReleasepedaldownwardandmoveslightlytotherightuntilitwaslocked
in.
3. Holdandpushgatetodesireddirection.
B. Resetpedal(OnlywhenoperatorhasNoreactionwhileusingremotecontrol)
1. Push pedal downward from locked position and slightly move to the left,
unlockedpedal.
2. AllowPedalriseuptoresetpositionandreleasepedal.
8
EMERGENCY RELEASE
Figure 10
A. Emergency Release of gate
1. Disconnect power
2. Push Release pedal downward and move slightly to the right until it was locked in down
position.

8
9
Entrapment Protection
Safety and Exit Loop
Figure11

9
10
Control Board Lay Out
Figure12

10
11
Gate Travel Limit Adjustment
Figure13
Turnupordownofbothwheelstoadjustdistanceinbetween,makegatestopat
thedesiredposition.
11
Gate Travel Limit Adjustment
Figure13
Turnupordownofbothwheelstoadjustdistanceinbetween,makegatestopat
thedesiredposition.
11
Gate travel limit adjustment
Figure 13
1. Turn up or down of both wheels to adjust distance between them, making gate stop on
position desired.

11
12
Use Remote Control
Device
Figure 14
Therearetwomodestosetremotecontrol:SelfstudyMode&NumericMode
Selfstudycodemaybesetupto60groups.
A. Selfstudymodecorrespondstoreceiverincontrolboard.Pressandhold
STUDYkey for3seconds untilflashinglight turnto solidbright, pressanykey on
remotecontroluntilSTUDYlightturntoflashingagain,settingnowisdone.Repeat
aboveifadditionalcodeneeded.
B. ExistingCodesremoval.PressSTUDYkeyandholdfor8seconds,watching
lightstate:flashingsolidflashing,settingisdone.AllexistingSelfstudycodeshave
beenremoved.
NumericMode
A. FirsttoturnSW9keytoONposition,nowcontrolboardisactivated.
B. Make a combination of code. On SW8, Set an 8digit combination to match
identical 8digit combination on Remote Control. Note: each switch could be
placedonup,middleorlowposition.Thereisnolimitforgroupsofcombinations.
C. On switch SW10, KEY 1 and KEY 2 are used for 2buttom model of remote
controls.Note:if
KEY1codewassetwithBUTTONONEonremotecontrol;KEY1willNOTworkwith
BUTTONTWOonremotecontrol.

12
13
Use DIP Switches
Figure 15 DIP switch
1.CLDELAY:GateClosingdelay,switchtoONposition,turntimerto16seconds.
2.TIMER:160Timer:Autoactivatedtoclosegateuponsettime(1~60seconds).
3. OSC: Remote control priority. Allow remote control to direct gate movement
whenevergateismovinginanydirection.Usefirstsignaltostopgate,usesecond
signaltomovegatetooppositedirection.
4. 1 PASS: Antitailgating system. It corresponds to underground safety loop.
Afterthevehiclehasclearedsafeloopoutsideofproperty,gatewillstarttoclose
immediatelywithoutopeningtolimit,whenONisselected.Ifsecondvehicleacross
loopatthistime,gatewillstop.Thesecondvehiclemustgetofftheloopandthen
gatewillcontinuetoclosecompletely.
5. SLAVE:Secondaryoperatoractivation.
6. OPEBL/R:ChoosegateopendirectionLeftorRight.
Use Infrared Control
Figure16
Followinfraredcontrolinstructiontoconnectpower.Commonwireisconnectedto
Commonpole,signalwireisconnectedtoOPENorCLOSEpole.

13
14
Use of External Receiver
Figure17
Externalconnectorsareinstalledontherearsideofmainboardprotectorbox.
Slave Operator Activation
Figure18
1. SetSLAVEswitchonSLAVECONTROLBOARDtoONposition.
2. UseULprovedelectricwireconnectDATAandDATAfromMastercontrol
boardtoSlavecontrolBoard,thenconnectDATA+andDATA+accordingly.
3. M/LINKlightturnstosolidbright.

14
16
2.AdjustknobonTIMERbetween0~60secondstoactivateoperator(Figure20)
15
Use Reversing Device
Figure19
1. CLOSE ERD: when closing gate, increase/decrease amount of force by
turningknobclockwise/counterclockwise.
2.OPENERD:Whenopeninggate,increase/decreaseamountofforceby
turningknobclockwise/counterclockwise.
3.Testdevicesensitivityevery6months.
Remote Control & Timer Delay Closing
Figure20
A. RemoteControldelayclosing
1. Choosetimedelaytoactivateoperatorbetween0~6secondsbyturningknob
onDELAY
B. Timerautomaticdelayclosing
1. OnDIPswitchSetkeyTIMERtoONposition(Figure15)
15
Use Reversing Device
Figure19
1. CLOSE ERD: when closing gate, increase/decrease amount of force by
turningknobclockwise/counterclockwise.
2.OPENERD:Whenopeninggate,increase/decreaseamountofforceby
turningknobclockwise/counterclockwise.
3.Testdevicesensitivityevery6months.
Remote Control & Timer Delay Closing
Figure20
A. RemoteControldelayclosing
1. Choosetimedelaytoactivateoperatorbetween0~6secondsbyturningknob
onDELAY
B. Timerautomaticdelayclosing
1. OnDIPswitchSetkeyTIMERtoONposition(Figure15)
15
Use Reversing Device
Figure19
1. CLOSE ERD: when closing gate, increase/decrease amount of force by
turningknobclockwise/counterclockwise.
2.OPENERD:Whenopeninggate,increase/decreaseamountofforceby
turningknobclockwise/counterclockwise.
3.Testdevicesensitivityevery6months.
Remote Control & Timer Delay Closing
Figure20
A. RemoteControldelayclosing
1. Choosetimedelaytoactivateoperatorbetween0~6secondsbyturningknob
onDELAY
B. Timerautomaticdelayclosing
1. OnDIPswitchSetkeyTIMERtoONposition(Figure15)

9949 Hayward Way, South El Monte, CA 91733
www.bestirongatemotor.com
Other manuals for CM-5-ACFP
2
Table of contents
Other Calimet Garage Door Opener manuals
Popular Garage Door Opener manuals by other brands

Chamberlain
Chamberlain Power Drive PD752 owner's manual

Nice
Nice SPY800KCE/V1 Instructions and warnings for installation and use

Erreka
Erreka NAOS Quick installation and programming guide

RIB
RIB BOSS 24V MASTER Technical drawings for projects

CAME
CAME MYTO ME installation manual

Merlin
Merlin Powerlift user guide