CAMDEN CV-110SPK User manual

CV-110SPK
Standalone Keypad/Prox Access Control
Installation Instructions
Page 1 of 8
1. Packing List
13
4"[44mm]
1 2
3 4
5 6
7 8
9 0
*#
515
16
"
[150mm]
2. Description
The CV-110SPK is a single door multifunction standalone
keypad with a wiegand output for interfacing to an access
control system or remote card reader. It is suitable for
mounting either indoor or outdoor in harsh environments.
It is housed in a strong, sturdy and vandal proof Zinc Alloy
electroplated case. The electronics are fully potted so the
unit is waterproof and conforms to IP68. This unit supports
up to 2000 users in either a Card, 4 digit PIN, or a Card +
PIN option. The built-in prox card reader supports 125KHZ
EM cards. The unit has many extra features including lock
output current short circuit protection, wiegand output, and a
backlit keypad. These features make the unit an ideal choice
for commercial and industrial applications such as factories,
warehouses, laboratories, banks and prisons.
3. Features
• 2000 users, supports Card, PIN, Card + PIN
• Backlit keys
• Zinc Alloy Electroplated anti-vandal case
• Waterproof, conforms to IP68
• Easy to install and program
• Wiegand 26 output for connection to a controller-
• Full programming from the keypad
• Can be used as a stand-alone keypad
• Wiegand 26 input for connection to external reader
• Adjustable Door Output time, Alarm time, Door Open time
• Very low power consumption (30mA)
• Fast operating speed, <20ms with 2000 users
• Lock output current short circuit protection
• Built in light dependent resistor (LDR) for anti-tamper
• Built in buzzer
• Red, Yellow and Green LEDS status indicators
Qty Name Remarks
1
1
1
2
2
1
Keypad
User manual
Screwdriver
Wall plugs
Self-tapping screws
Torx screw
0.8” x 2.4”Φ(20 mm×60 mm)
0.24” x 1.2”Φ (6 mm×30 mm)
0.16” x 1.1”Φ(4 mm×28 mm)
0.12” x 0.24”Φ(3 mm×6 mm)

Standalone Keypad/Prox Access Control
5. Specifications
Operating Voltage 12V DC ±10%
User Capacity 2,000
Card Reading Distance 1.25” to 2.4” (3 cm to 6 cm)
Active Current < 60mA
Idle Current 25±5 mA
Lock Output Load Max 3A
Alarm Output Load Max 20mA
Operating Temperature -49°F to 140°F (-45°C to 60°C)
Operating Humidity 10% - 90% RH
Waterproof Conforms to IP 68
Adjustable Door Relay time 0 - 99 seconds
Adjustable Alarm Time 0 - 3 minutes
Wiegand Interface Wiegand 26 bit
Wiring Connections Electric Lock, Exit Button, External Alarm, External Reader
Dimensions 5 15/16” H x 1 3/4” W x 1” D (150 mm x 44 mm x 25 mm)
Page 2 of 8
4. Quick Reference Programming Guide
To enter programming mode *Master Code #
999999 is the default factory master code
To exit from the programming mode *
Note: You must be in programming mode to program the following feature.
To change the master code 0New Code #New Code #
The master code can be 6 to 8 digits
To add a PIN user
1User ID Number #PIN #
The ID number is any number between 1 & 2000. The
PIN is any four digits between 0000 & 9999 with the
exception of 1234 which is reserved. Users can be
added continuously without exiting programming mode.
To add a card user
1Read Card #
Cards can be added continuously without exiting
programming mode
To delete a PIN or a card user
2User ID Number #for a PIN user or
2Read Card #for a card user
Users can be deleted continuously without exiting
programming mode.
To unlock the door for a PIN user Enter the PIN then press #
To unlock the door for a card user Present the card

Standalone Keypad/Prox Access Control
• Remove the back cover from the keypad using the
supplied special screw driver
• Drill 2 holes on the wall for the Self tapping screws and
1 hole for the cable
• Put the supplied wall plugs into the two holes
• Attach the back cover rmly to the wall with the
2 Self tapping screws
• Thread the cable through the cable hole
• Attach the keypad to the back cover
6. Installation
7. Wiring
Color Function Description
Pink BELL_A Doorbell
Pale Blue BELL_B Doorbell
Green D0 Wiegand output D0
White D1 Wiegand output D1
Grey ALARM Alarm negative (alarm positive connected 12 V+)
Yellow OPEN Exit button (the other end connected GND)
Brown D_IN Door Contact switch (the other end connected GND)
Red 12V+ 12V + DC Regulated Power Input
Black GND 12V - DC Regulated Power Input
Blue NO Relay Normally Open
Purple COM Relay Common
Orange NC Relay Normally Closed
Common power supply diagram:
Power supply
BELL_A PINK
D_IN BROWN
D0 GREEN
GND BLACK
ALARM GRAY
COM PURPLE
BELL_B PINK
+12V RED
D1 WHITE
NO BLUE
OPEN YELLOW
NC ORANGE
Bell
Connect
Alarm
Exibit Button
Door Contact
12V +-
Fail Secure Lock
Fail Safe Lock
Page 3 of 8
+

Standalone Keypad/Prox Access Control
8. To Reset to Factory Default
The unit uses a LDR (light dependent resistor) as an
anti-tamper alarm. If the keypad is removed from the cover,
the tamper alarm will operate.
a. Disconnect power from the unit
b. Press and hold # key while powering the unit back up
c. On hearing two “Beeps” release # key, system is now
back factory settings
9. Anti-Tamper Alarm
10. Sound and Light indication
11. Detailed Programming Guide
Operation Status Red Light Green Light Yellow Light Buzzer
Power on -Bright -Beep
Stand by Bright - --
Press keypad - - -Beep
Operation successful - Bright -Beep
Operation failed - - -Beep/Beep/Beep
Enter into programming mode Bright - - -
In the programming mode - - Bright Beep
Exit from the programming mode Bright - -Beep
Open the door - Bright -Beep
Alarm Bright - -Alarm
To enter the programming mode * Master code #
999999 is the default factory master code
To exit from the programming mode *
Note: You must be in programming mode to perform any of the following functions
To change the master code 0 New code # New code #
The master code can be 6 to 8 digits long
Setting the working mode:
Set valid card only users
Set valid card and PIN users
Set valid card or PIN users
3 0 # Entry is by card only
3 1 # Entry is by card and PIN together
3 2 # Entry either by card or PIN (default)
11.1 User Settings
Page 4 of 8
Note: Only the installer data is restored, user
data will not be affected.

Standalone Keypad/Prox Access Control
To add a user in either card or PIN mode, i.e. in the 3 2 # mode. (Default setting)
To add a Pin user 1 User ID number # PIN #
The ID number is any number between 1 & 2000.
The PIN is any four digits between 0000 & 9999 with
the exception of 1234 which is reserved. Users can be
added continuously without exiting programming mode
as follows:
1 User ID no 1 # PIN # User ID no 2 # PIN #
To delete a PIN user 2 User ID number # Users can be deleted
continuously without exiting programming mode
To change the PIN of a PIN user
(This step must be done out of programming mode)
* ID number # Old PIN # New PIN #
New PIN #
To add a card user (Method 1)
This is the fastest way to enter cards. The user ID
number is automatically generated.
1 Read card #
Cards can be added continuously without exiting
programming mode
To add a card user (Method 2). This is the alternative
way to enter cards using User ID Allocation. In this
method a User ID is allocated to a card. Only one
user ID can be allocated to a single card.
1 ID number # Card #
Users can be added continuously without exiting
programming mode
To add card user (Method 3)
Card number is the last 5-8 digits printed on the
back of the card, user ID number is automatically
generated
1 Card number #
Users can be added continuously without exiting
programming mode
To add a card user (Method 4)
In this method a User ID is allocated to a card
number. Only one user ID can be allocated to the
card number
1 ID number # Card number #
Users can be added continuously without exiting
programming mode
To delete a card user by card. Note users can
be deleted continuously without exiting
programming mode
2 Read Card #
To delete a card user by user ID. This option can
be used when a user has lost their card 2 ID number #
To delete a card user by card number.
This option can be used when the user want to
make the change but the card has been lost
2 Card number #
Note users can be deleted continuously without exiting
programming mode
Page 5 of 8

Standalone Keypad/Prox Access Control
To add a card and PIN user in card and PIN mode ( 3 1 # )
To Add a card and Pin user
(The PIN is any four digits between 0000 & 9999
with the exception of 1234 which is reserved.)
Add the card as if for a card user. See page 5
Press * to exit from the programming mode
Then allocate the card a PIN as follows:
* Read card 1234 # PIN # PIN #
To change a PIN in card and PIN mode (Method 1)
Note that this is done outside the programming mode
so the user can do this themselves
* Read Card Old PIN # New PIN #
New PIN #
To change a PIN in card and PIN mode (Method 2)
Note that this is done outside the programming mode
so the user can do this themselves
* ID number # Old PIN # New PIN #
New PIN #
To delete a Card and PIN user just delete the card 2 User ID #
To add a card user in card mode ( 3 0 # )
To Add and Delete a card user The operating is the same as adding and deleting
cards in mode 3 2 #
To delete All users
To delete ALL users. Note: This removes all user
codes. 2 0000 #
To unlock the door
For a PIN user Enter the PIN then press #
For a card User Read card
For a card and PIN user Read card then enter PIN #
Page 6 of 8

Standalone Keypad/Prox Access Control
Alarm output time
To set the alarm output time (0~3 minutes) Factory
default is 1 minute 5 0~3 #
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a
10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes,
depending on the option selected below.
Normal status: No keypad lockout or alarm
(factory default) 7 0 # (Factory default setting)
Keypad lockout enable 7 1 #
Alarm and inside buzzer enable 7 2 #
To remove the alarm
To reset the Door Forced Open Alarm Read valid card or Master Code #
To reset the Door Propped Open Alarm Close the door or Read valid card or
Master Code #
Page 7 of 8
Relay Output Dealy Time
To set door relay strike time * Master code # 4 0~99 # *
0-99 is to set the door relay time 0-99 seconds
Door Open Detection
Door Propped Open Alarm. When used with an optional magnetic contact or built-in magnetic
contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep
automatically to remind people to close the door and continue for 1 minute before switching off automatically.
Door Forced Open Alarm. When used with an optional magnetic contact or built-in magnetic contact of the lock, if
the door is opened by force, or if the door is opened after 20 seconds of the electro-mechanical lock not closing
properly, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0~3
minutes with the default being 1 minute.
To disable door open detection. (Factory default) 6 0 #
To enable door open detection 6 1 #
11.2 Door Settings

Standalone Keypad/Prox Access Control
Push Buttons Keypads Strikes Magnetic Locks Key Switches Relays & Timers Access Control
5502 Timberlea Blvd.,
Mississauga, ON Canada
L4W 2T7
www.camdencontrols.com
Toll Free: 1.877.226.3369
File: Standalone Keypad/Prox Access Control
Installation Instructions.indd R3
Revision: 05/03/2018
Part No.: 40-82B190
In this mode the keypad provides a 26 bit wiegand output. The wiegand data lines can be connected to any controller which
supports the 26 bit wiegand protocol.
Every key pressed generates an 8 bit data stream that is transmitted over the wiegand bus.
12. Interfacing to an Access Control System
12.1 Keypad 8 bit Burst Mode
Page 8 of 8
BELL_A PINK
D_IN BROWN
D0
D0
12V
GREEN
GND BLACK
ALARM GRAY
COM PURPLE
BELL_B PINK
+12V RED
D1
D1
GND
WHITE
NO BLUE
OPEN YELLOW
NC ORANGE
Bell
Connect
Key Output Key Output
011110000 610010110
1 11100001 710000111
2 11010010 801111000
3 11000011 901101001
4 10110100 *01011010
5 10100101 #01001011
Access Controller
Table of contents
Other CAMDEN IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

TrustOne Global
TrustOne Global TSG-550 Setup guide

TG Electronics
TG Electronics HSY-S212W user manual

SoundCraft
SoundCraft Secura Key Radio Key 600 Operating & installation guide

Delta Controls
Delta Controls ADM-2W704 Installation and application guide

Anviz
Anviz T5S user manual

PRASTEL
PRASTEL EASYKA manual