The HEWI wallreader basis-unit ES5403 is defined for usage within the electronic locking
system ES5000 in combination with reading-modules ES5401, ES5402 or ES5404 to control
peripheral devices like electric door openers, electric locks, electric door and gate drives,
elevators and so on.
The usage for scopes apart from the usual requests for electronic locking systems has to be
authorized by HEWI in the doubt. The basis-unit is suitable for security-critical applications
only in combination with the reading-modules ES5401 / ES5402 / ES5404 and correct
installation (see beyond). It must not be used in humid rooms or outside of buildings. For
further informations contact the HEWI Servicecenter locking systems, fon +49 5691 82-200.
The usage in dusty environment without further protections (for instance the mountage in
dust protected casings) is not allowed.
Warning
a) Security against manipulation (unauthorized access)
Attention: If using the ES5403 manipulation in access-direction is possible, if the basis-unit is
not installed in the secured inside area (seen in access direction). That means that by
removing the basis-unit the connection cables could be used for operating the peripheral
device. For security-relevant applications the reader-module has to be seperated from the
basis-unit. Please use the ES5403 in the secured inside area in combination with the
ES5401 / ES5402 / ES5404 in the „unsecured“ outside area.
b) Environmental requirements
Combined with the HEWI covers the protection-class corresponds to IP21, therefore the
ES5400 has to be used inside of buildings an in dry rooms. For the usage in humid rooms or
in dusty environment, specially designed products are offered.
c) Combination with peripheral devices
For the operation with peripheral devices the operating instructions, technical specifications
of the devices have to be observed.
d) Installation / maintenance
Installation and maintenance musted be executed without power supply – danger of injury or
damage of the product or devices.
e) Sensitivity against contact (z.B. ESD)
Never touch electronical components or circuits of the circuit board, otherwise you could
damage the wallreader irreparable.
f) Combination with electrical door openers / special time zones
If a special time zone should be used, which operates an electrical door opener for a longer
time-period (> 20 s, e.g. opening from 9 to 12 am), you must use a door opener which could
endure permanent power.
g) Non-operating at blackout
During a blackout (no power-supply) the wallreader is non-operational. The wallreader has
an included battery-buffer, which guarantees the perservation of the stored data
(programming, internal clock) Nonetheless plase check the internal time after a longer
blackout. If a special time zone or a manual activated toggle-function was in work during the
blackout, it will be automatically deactivated for security reasons, even if it should be active in

HEWI Installation-instruction
M1000_123_ES5403_DE-Vers-001.pdf M1000.123 Page 2of 8
HEWI P.O. Box 1260 D-34442 Bad Arolsen
the moment after the blackout. For example: A special time zone has been programmed
between 2 an 4 om. During this time the relay is activated, a peripheral electrical door opener
is active, the door can be used by everyone without valid access-rights. At 3 pm a blackout
occures, at half past 3 the power supply returns. The relay isn’t activated any more, the door
can only be opened by people with vaild access-rights.
h) Danger of lock-out or lock-in during installation
Ensure, that during the installation of a wallreader combined with a door-lock, the door can
always be opened manually, even if the wallreader or the door-lock is not working (e.g.
because of incorrect installation). Always make complete function-test after installation.
i) Interferences
Strong electro-magnetic fields (e.g. transformers, tomographs, ...) and transmitters (IT-
networks, telecommunications, ...) near the wallreader can cause malfunction or
interferences!
j) Connecting multiple reading-modules with a basis-unit / a compact-wallreader
Up to 8 reading-modules ES5401 / ES5402 / ES5404 can be connected to a basis-unit
ES5403. Up to 7 reading-modules ES5401 / ES5402 / ES5404 can be connected to a
compact-wallreader ES5400. A unique adress of the reading-modules is important (adress-
switch). Each adress (1..9) must je used once per basis-unit / compact-wallreader (see figure
5).
The data connection uses a RS485-Bus, that means, the connection-cable is wired from the
basis-unit / compact-wallreader to the first reading-module and from there to the second
reading-module an so on. Umbrella wiring is not possible!
Variations
The wallreader basis-unit ES5403 can be expanded with additional reading-modules ES5401
/ ES5402 / ES5404. These can be connected with the connection-bar. For Details see the
installation manual of those products.
Alternatives
Alternative to the wallreader basis- unit ES5403 the compact wallreader ES5400 can be
used.
Preparation of installation
Please check before the installation, if the wallreader you tend to install is suitable for your
application! Check especially:
•Electrical data (voltage, current, power) of the wallreader and the peripheral devices.
•Suitability of the wallreader for the environment, especially the protection class IP21.
•The request at security of the system. In doubt always use an additional reader-module
which will be installed on the „unsecure“ side, in combination with a basis-unit ES5403 or
the compact-wallreader ES5400, installed on the „secure“ side.
•Please notice, that the security of the whole system always depends on the quality of
peripheral devices such as doors, self-locking-locks, burglar-protected products, or an
alarm-device. In addition the installation has always to consider the supposed attacking-
direction.
•Please let security-relevant installations be implemented by suitable specialists.
Required Tools
For the installation a screwdriver or a suitable screwdriver for mounting other screws is
needed. To strip the connection cables a cable stripper or a side cutter is needed.

HEWI Installation-instruction
M1000_123_ES5403_DE-Vers-001.pdf M1000.123 Page 3of 8
HEWI P.O. Box 1260 D-34442 Bad Arolsen
Attention: After the installation the relays are active. Therefore a door opener could be active.
According to the application, a door could be unlocked and used by everyone. If this is not
wished, please programm the wallreader instantaneously using the HEWIKey5
Administration-software, the programming device and the programming key / card. In doubt
please contact the HEWI Servicecenter locking systems, fon +49 5691 82-200.
Ensure, that during the installation of a wallreader combined with a door-lock, the door-lock,
the door can always be opened manually, even if the wallreader or the door-lock is not
working (e.g. because of incorrect installation). Always make a complete function-test after
installation.

HEWI Installation-instruction
M1000_123_ES5403_DE-Vers-001.pdf M1000.123 Page 4of 8
HEWI P.O. Box 1260 D-34442 Bad Arolsen
Description of standard-
installation 1. Lock the basis-unit ES5403 in backside
of the cover (ES5410).
2. The sub-finery-socket (depth min. 40
mm) should be mounted smooth to the
wall.
3. Install all neccessary connections
(power supply, relay, etc.) as shown in the
wiring plan beyond. Plug the still
connection cables into the right connector.
They fit automatically.

HEWI Installation-instruction
M1000_123_ES5403_DE-Vers-001.pdf M1000.123 Page 5of 8
HEWI P.O. Box 1260 D-34442 Bad Arolsen
3a. De-Installation:
Move the lever with a small screwdriver (or
smthg. similar) and remove the cable.
.
4. Mount the basis-unit onto the socket
using the enclosed screws. Turn the
screws carefully so that the circuit board
doesn’t become distorted. Alternative use
4 screws at the outside fitting-points.
6. Plug the cover onto the wallreader.
After switching on the power-supply, a beep sounds. The red and green LED blink in change
every second. Simultaneously the relays are activated. This is because to ensure the door
opening with non-personalised wall-readers.
For further steps (esp. programming) see the manual of the HEWIKey 5 Administration
software.

HEWI Installation-instruction
M1000_123_ES5403_DE-Vers-001.pdf M1000.123 Page 6of 8
HEWI P.O. Box 1260 D-34442 Bad Arolsen
Description of known problems during installation including correctional
action
•Connection cables are too thick and cannot be fitted into the connection-bar: Please use
luster terminals and a short linkup of the cable-type specified in the data-sheet beyond.
•The wallreader (basis-unit + reading-module) isn’t working correctly, for instance
identifiers aren’t red: Check the Position of the adress-switch of the reading-modules.
Each module needs a unique adress (see installation-instruction of the modules ES5401 /
ES5402 / ES5404).
Control of function
Please always check the complete function of the installation.
Maintenance
Basically the ES5403 doesn’t need maintenance. However, we recommend to check the
actuality of the internal time regularly. At least make the checks during the time switches
(summer- wintertime).
We further recommend a regulary check of the correct function of the wallreader, especially
in security-relevant areas. Security relevant can be every area, which will be affected by a
possible malfunction or wrong programming. This means especially alarm-systems, which
are operated by the wallreader or locks in escape- or outside-doors.
Please control the event-protocolls, which can be evaluated using the programming-device
and the HEWIKey Software. Coceivably you´ll find indications of a wrong-programming of the
locking system, which can be critical (e.g. an active toggle-function, which wasn’t planned or
an occured access from a person without access-rights to given time). In that case, please
check the correct programming of the wallreader first (especially time, holidays, special time
zones) and the ident-media (especially access-rights to given time, groups and validity). In
doubt, contact the HEWI Servicecenter locking systems, fon +49 5691 82 – 200.
Care
HEWI products are easy-care. Generally speaking, an occasional wipe with a damp cloth is
enough, however, you fell you have to use detergents, you should take note of the following
information: Only use detergents with ph-rating of between 6 and 8. Detergents containing
active substances such as phospates, soap and tensides may be used. Detergents
containing acids, alkalis, bleach or scouring agents may not be used. Nor should utensils
with a scouring effect such as brushes etc. be used. Usage of any detergent requires full
compliance with the manufacturer’s instructions (concentration, soaking time etc.).
If this is not done, the surface finishes of the HEWI products may suffer as a result and
sustain damage. HEWI accepts no liability whatsoever for damage occuring from incorrect
handling.
For further information please contact HEWI Servicecenter locking systems, fon +49 5691
82-200.

HEWI Installation-instruction
M1000_123_ES5403_DE-Vers-001.pdf M1000.123 Page 7of 8
HEWI P.O. Box 1260 D-34442 Bad Arolsen
Data sheet
General
Product description Wallreader basis-unit ES5403
Casing
Length x width x height 70 x 70 x 44 mm
Material synthetic
Installation depth min. 40 mm
Installation
diameter
50 mm
Power supply /
connections
Current
Input
12 - 37 V DC unregulated
23 - 27 V AC
4 - 37 V DC / 4 - 27 V AC 30 - 100 Hz +/- 10%
Current consumption max. 500 mA without load (with 6 reader modules )
Switching capacity Relay Closer/NO max. 40 V AC/DC / 1,6 A
Relasi Opener/NC max. 40 V AC/DC / 0,25 A
Relais Opener/NC (Alarm) max. 40 V AC/DC / 0,25 A
Connection cable I-Y(ST)Y 8 x 2 x 0,8
Power adaptor Depending on number of wallreaders.
Specific data
Operating temperature -20 bis +70 °C
Storage temperature -40 bis +85 °C
Humidity Max. 95% not condensing
Outputs 3 Relays (Photomos-Relays) 1 x NO (Closer), 2 x NC (Opener)
Data interfaces RS485 e.g. for operating a programmable logic controller
RS485 for communication with up to 8 reading-modules ES5401
/ ES5402 / ES5404
Communication with
programming device
Inducticve coupling.
Connection configuration See figure
Memory size 25.000 or 60.000 identifiers (after consultation of HEWI)
Time zones 2 per identifier
Special time zones 20, programmable with administration software HEWIKey5
Tests
CE-test Basic technical standard EN 5002 1081

HEWI Installation-instruction
M1000_123_ES5403_DE-Vers-001.pdf M1000.123 Page 8of 8
HEWI P.O. Box 1260 D-34442 Bad Arolsen
Wiring plan:
inputs:
J1.1: input 1
J1.2: input 1
J1.3: input 2
J1.4: input 2
J1.5: power supply
J1.6: power supply
Input 1 needs to be connected. If there is no alarm-device in use, the power supply has to be
connected to input 1.
outputs: Serial interfaces:
J2.1: closer 1 (NO) J3.1: VCC (onyl for seperated reader-module)
J2.2: closer 1 (NO) J3.2: RS485-A (onyl for seperated reader-module)
J2.3: opener 1 (NC) J3.3: RS485-B (onyl for seperated reader-module)
J2.4: opener 1 (NC) J3.4: GND (onyl for seperated reader-module)
J2.5: opener 2 (NC) J3.5: RS485-A (SPS-interface)
J2.6: opener 2 (NC) J3.6: RS485-B (SPS-interface)
Connection basis-unit ES5403 <--> reading-module ES5401:
Basis-unit ES5403 Reading-module ES5401
RS485-A J3.2 2 (socket X1 or X2)
RS485-B J3.3 3 (socket X1 or X2)
VCC J3.1 1 (socket X1 or X2)
GND J3.4 4 (socket X1 or X2)
J1
J2
J3
J4
6 5 4 3 2 1
6 5 4 3 2 1 6 5 4 3 2 1
1 2 3 4 5
Backside view