Passive Probe
P500 User Manual Guide
Passive Probe
P500 User Manual Guide
SPECIFICATIONS, PERFORMANCE AND COMPLIANCE
www.CarlisleIT.com www.CarlisleIT.com
Technical Specifications
Dividing ratio 10:1
Input capacitance 15 pF +/- 2 pF
Compression range 10 pF ~ 25 pF
Frequency range DC-200 MHz
Rise time < 2.1 ns
Cable length 1.4 m
Input impedance 10M ohms ± 1%
Rated voltage when using touch-protected test equipment [a]
[a] Frequency-dependent see derating curve
PB-Free
Processing
Compliant
*EU REACH
Compliant
**EU RoHS2
Compliant
***China
RoHS
Compliant
WEEE
Compliant
ELV
Compliant
OVERVIEW AND SAFETY PRECAUTIONS
The P500 family of passive probes and accessories provide accurate and safe attachment
to AC and DC test circuits for measurement of signals on analog and digital oscilloscopes in
Category Ill and IV circuits. This probe and accessories adhere
to IEC 61010-031 edition 2015.
PASSIVE PROBE
MARKINGS
WARNING
Failure to follow all instructions in this manual may defeat the safety features and result in
injury or death.
Before using the P500, read and understand the safety warnings, ratings and instructions
contained in this manual.
The P500 family of probes and accessories are not intended for use in wet or damp
locations. Electric shock may result.
There are no user serviceable parts in the P500 probe or accessories.
Do not attempt to open or disassemble.
Probe must be fully connected to the measurement instrument prior to connection to the
device under test.
Probe must be disconnected from the device under test prior to disconnecting from the
measurement instrument.
Failure to follow all of the instructions
in this manual may defeat the safety
features and result in injury or death.
Double Insulated
UG-10173-011219
COMPENSATION PROCEDURE AND CLEANING
When necessary, the probe and accessories can be cleaned with a
damp cloth using water and a mild detergent.
Adequate drying time should be allowed before use.
WARNING
Dry the probe completely before attempting to make voltage
measurements.
For an accurate indication of the measuring signal, it is necessary to adjust the capacity
of the probe to the input capacity of the oscilloscope. For this purpose the probe has an
adjusment screw in the handling section. Connect the probe to the oscilloscope and the
tip to the reference calibration signal of the oscilloscope.
Turn the adjustment scew until the oscilloscope shows an exact square wave.
SPECIFICATIONS, PERFORMACE AND COMPLIANCE
SAFETY HANDLING AND OPERATION
Probe must be fully connected to the measurement instrument prior to connection to
the device under test Probe must be disconnected from the device under test prior to
disconnecting from the measurement instrument.
Barriers are provided to indicate hazardous areas that cannot be touched during operation.
Voltage Ratings
400 V Maximum input voltage of 400 V AC+ DC
300 V Maximum input voltage of 300 V AC+ DC
Category Ratings
CAT II Suitable for connection to category two circuits.
CAT III Suitable for connection to category three circuits.
CAT IV These probes are not suitable for attachment to CAT IV circuits.
When using the Hook Tip it is safe to use the rib provided for actuation of the hook tip.
Passive Probe
P500 User Manual Guide Passive Probe
P500 User Manual Guide
ACCESSORIES
Accessories Voltage Ratings
Alligator Ground Lead 400 V CAT II, 300 V CAT III
Hook Tip 400 V CAT II, 300 V CAT III
BNC Adapter Not Applicable
Rf Ground Not Applicable
Screwdriver Not Applicable
Tip Cover Not Applicable
Screwdriver
Alligator Ground
RF Ground
Tip Cover
Hook tip
BNC Adapter

Other Carlisle Measuring Instrument manuals

Carlisle Ransburg IntelliFlow RM2 User manual

Carlisle

Carlisle Ransburg IntelliFlow RM2 User manual

Carlisle Ransburg 310-9000 User manual

Carlisle

Carlisle Ransburg 310-9000 User manual

Popular Measuring Instrument manuals by other brands

Mitutoyo ID-N user manual

Mitutoyo

Mitutoyo ID-N user manual

Tektronix AM 503B Series instructions

Tektronix

Tektronix AM 503B Series instructions

Hanna Instruments Checker HI707 instruction manual

Hanna Instruments

Hanna Instruments Checker HI707 instruction manual

Extech Instruments GRT300 user guide

Extech Instruments

Extech Instruments GRT300 user guide

YEO-KAL 801C user manual

YEO-KAL

YEO-KAL 801C user manual

SUTO D554 0031 Instruction and operation manual

SUTO

SUTO D554 0031 Instruction and operation manual

Major tech MT942 user manual

Major tech

Major tech MT942 user manual

UEi AQM4 instruction manual

UEi

UEi AQM4 instruction manual

Agilent Technologies E5505A installation guide

Agilent Technologies

Agilent Technologies E5505A installation guide

iSTEK NeoMet 79P instruction manual

iSTEK

iSTEK NeoMet 79P instruction manual

HP 8719D Installation note

HP

HP 8719D Installation note

Telecommunications Techniques Corporation interceptor 147 Reference manual

Telecommunications Techniques Corporation

Telecommunications Techniques Corporation interceptor 147 Reference manual

G.R.A.S. 90AA instruction manual

G.R.A.S.

G.R.A.S. 90AA instruction manual

Endress+Hauser Proline 500 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline 500 Brief operating instructions

Ametek ORTEC digiBASE user manual

Ametek

Ametek ORTEC digiBASE user manual

SIMARINE PICO user manual

SIMARINE

SIMARINE PICO user manual

PKP DB51 instruction manual

PKP

PKP DB51 instruction manual

ETI BLUETHERM ONE operating instructions

ETI

ETI BLUETHERM ONE operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.