manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Carlisle
  6. •
  7. Measuring Instrument
  8. •
  9. Carlisle P500 Assembly instructions

Carlisle P500 Assembly instructions

Other Carlisle Measuring Instrument manuals

Carlisle Ransburg 310-9000 User manual

Carlisle

Carlisle Ransburg 310-9000 User manual

Carlisle Ransburg IntelliFlow RM2 User manual

Carlisle

Carlisle Ransburg IntelliFlow RM2 User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Passive Probe
P500 User Manual Guide
Passive Probe
P500 User Manual Guide
SPECIFICATIONS, PERFORMANCE AND COMPLIANCE
www.CarlisleIT.com www.CarlisleIT.com
Technical Specifications
Dividing ratio 10:1
Input capacitance 15 pF +/- 2 pF
Compression range 10 pF ~ 25 pF
Frequency range DC-200 MHz
Rise time < 2.1 ns
Cable length 1.4 m
Input impedance 10M ohms ± 1%
Rated voltage when using touch-protected test equipment [a]
[a] Frequency-dependent see derating curve
PB-Free
Processing
Compliant
*EU REACH
Compliant
**EU RoHS2
Compliant
***China
RoHS
Compliant
WEEE
Compliant
ELV
Compliant
OVERVIEW AND SAFETY PRECAUTIONS
The P500 family of passive probes and accessories provide accurate and safe attachment
to AC and DC test circuits for measurement of signals on analog and digital oscilloscopes in
Category Ill and IV circuits. This probe and accessories adhere
to IEC 61010-031 edition 2015.
PASSIVE PROBE
MARKINGS
WARNING
Failure to follow all instructions in this manual may defeat the safety features and result in
injury or death.
Before using the P500, read and understand the safety warnings, ratings and instructions
contained in this manual.
The P500 family of probes and accessories are not intended for use in wet or damp
locations. Electric shock may result.
There are no user serviceable parts in the P500 probe or accessories.
Do not attempt to open or disassemble.
Probe must be fully connected to the measurement instrument prior to connection to the
device under test.
Probe must be disconnected from the device under test prior to disconnecting from the
measurement instrument.
Failure to follow all of the instructions
in this manual may defeat the safety
features and result in injury or death.
Double Insulated
UG-10173-011219
COMPENSATION PROCEDURE AND CLEANING
When necessary, the probe and accessories can be cleaned with a
damp cloth using water and a mild detergent.
Adequate drying time should be allowed before use.
WARNING
Dry the probe completely before attempting to make voltage
measurements.
For an accurate indication of the measuring signal, it is necessary to adjust the capacity
of the probe to the input capacity of the oscilloscope. For this purpose the probe has an
adjusment screw in the handling section. Connect the probe to the oscilloscope and the
tip to the reference calibration signal of the oscilloscope.
Turn the adjustment scew until the oscilloscope shows an exact square wave.
SPECIFICATIONS, PERFORMACE AND COMPLIANCE
SAFETY HANDLING AND OPERATION
Probe must be fully connected to the measurement instrument prior to connection to
the device under test Probe must be disconnected from the device under test prior to
disconnecting from the measurement instrument.
Barriers are provided to indicate hazardous areas that cannot be touched during operation.
Voltage Ratings
400 V Maximum input voltage of 400 V AC+ DC
300 V Maximum input voltage of 300 V AC+ DC
Category Ratings
CAT II Suitable for connection to category two circuits.
CAT III Suitable for connection to category three circuits.
CAT IV These probes are not suitable for attachment to CAT IV circuits.
When using the Hook Tip it is safe to use the rib provided for actuation of the hook tip.
Passive Probe
P500 User Manual Guide Passive Probe
P500 User Manual Guide
ACCESSORIES
Accessories Voltage Ratings
Alligator Ground Lead 400 V CAT II, 300 V CAT III
Hook Tip 400 V CAT II, 300 V CAT III
BNC Adapter Not Applicable
Rf Ground Not Applicable
Screwdriver Not Applicable
Tip Cover Not Applicable
Screwdriver
Alligator Ground
RF Ground
Tip Cover
Hook tip
BNC Adapter