1--2
T-334
1.3.12 Autotransformer
An autotransformer may be provided to allow operation
on 190/230, 3-phase, 50/60 Hz power. The
autotransformer raises the supply voltage to the
nominal 380/460 volt power required by the base unit.
The autotransformer may also be fitted with an
individual circuit breaker for the 230 volt power.
If the unit is equipped with an autotransformer and
communications module, the autotransformer will be
fitted with a transformer bridge unit (TBU) to assist in
communications.
1.3.13 Temperature Recorder
The units may be fitted with an electronic temperature
recording device manufactured by the Partlow
Corporation.
1.3.14 Gutters
Rain gutters may be fitted over the control box and
recorder section to divert rain away from the controls.
The different gutters include standard length bolted
gutters, extended length gutters and riveted gutters.
1.3.15 Handles
The unit may be equipped with handles to facilitate
access to stacked containers. These handles may
include fixed handles (located at the sides of the unit)
and/or a hinged handle at the center (attached to the
condenser coil cover).
1.3.16 Thermometer Port
The unit may be fitted with ports in the front of the frame
for insertion of a thermometer to measure supply and/or
return air temperature. If fitted, the port(s) will require a
cap and chain.
1.3.17 Water Cooling
The refrigeration system may be fitted with a water
cooled condenser. The condenser is constructed using
copper-nickel tube for sea water applications. The water
cooled condenser is in series with the air cooled
condenser and replaces the standard unit receiver.
When operating on the water cooled condenser, the
condenser fan is deactivated by either a water pressure
switch or condenser fan switch.
1.3.18 Back Panels
Back panel designs that may be fitted include panels of
aluminum and stainless steel. Panels may have access
doors and/or hinge mounting.
1.3.19 460 Volt Cable
Various power cable and plug designs are available for
the main 460 volt supply. The plug options tailor the
cables to each customer’s requirements.
1.3.20 230 Volt Cable
Units equipped with an autotransformer require an
additional power cable for connection to the 230 volt
source. Various power cable and plug designs are
available. The plug options tailor the cables to each
customers requirements.
1.3.21 Cable Restraint
Various designs are available for storage of the power
cables. These options are variations of the compressor
section front cover.
1.3.22 Upper Air (Fresh Air Make Up)
The unit may be fitted with an upper fresh air makeup
assembly. The fresh air makeup assembly is available
with a vent positioning sensor (VPS) and may also be
fitted with screens.
1.3.23 Lower Air (Fresh Air Make Up)
The unit may be fitted with a lower fresh air makeup
assembly. The fresh air makeup assembly is available
with a vent positioning sensor (VPS) and may also be
fitted with screens.
1.3.24 Power Correction
The unit may be fitted with a set of power factor
correction capacitors to assist in correction of
imbalance in current draw by the compressor.
1.3.25 Evaporator
Evaporator section is equipped with a hermetic thermal
expansion valve. The evaporator may also be equipped
with an expansion bypass solenoid valve (XBSV).
1.3.26 Evaporator Fan Operation
Two evaporator fan motor operation systems are
available. On units with Normal Evaporator Fan
operation, opening of an evaporator fan internal
protector will shut down the unit. On units equipped with
Single Evaporator Fan capability, additional relays are
installed to allow the unit to continue to operate on a
single fan. Units may also be equipped with single phase
or three--phase evaporator fan motors.
1.3.27 Labels
Operating Instruction and Function Code listing labels
differ, depending on the options installed. For example,
additional operating instructions are required to
describe start-up of a unit equipped with an
autotransformer. Labels available with additional
languages are listed in the parts list.
1.3.28 Plate Set
Each unit is equipped with a tethered set of wiring
schematic and wiring diagram plates. The plate sets are
ordered using a seven digit base part number and a two
digit dash number.
1.3.29 Controller
Two different controllers are available:
1. Remanufactured - Controller is the equivalent of a
new OEM controller and is supplied with a 12 month
warranty.
2. Repaired - Controller has had previous faults repaired
and upgraded with the latest software.
Note: Repaired controllers are NOT to be used for
warranty repairs; only full OEM Remanufactured
controllers are to be used.
Controllers will be factory equipped with the latest
version of operational software, but will NOT be
configured for a specific model number and will need to
be configured at the time of installation or sale.
1.3.30 Condenser Grille
Two styles of condenser grilles are available: direct
bolted grilles and hinged grilles.
1.3.31 Emergency Bypass
The unit may be equipped with switches to allow
emergency bypass of the controller. The Emergency
Bypass switch functions to bypass the controller in the
event of controller failure.