CDI TORQUE 2503-F-DTC User manual

DTC
DIGITAL
TORQUE
CHECKER
PAGE LANGUAGE
1 English

1
IMPORTANT SAFETY INSTRUCTIONS
WARNING Risk of flying particles.
Do not apply torque above rated capacity of DTC.
Over-torquing can cause breakage. Force against flex stops on flex head can cause
head breakage. An out of calibration DTC can cause part or tool breakage. Broken
hand tools, sockets or accessories can cause injury. Excess force can cause
crowfoot or flare nut wrench slippage.
Read this manual completely before using DTC.
For personal safety and to avoid DTC damage, follow good professional tool
and fastener installation practices.
Periodic recalibration is necessary to maintain accuracy.
Wear safety goggles, user and bystanders.
Be sure all components, including all adaptors, extensions, drivers and sockets
are rated to match or exceed torque being applied.
Observe all equipment, system and manufacturer's warnings, cautions and
procedures when using this checker.
Use correct size adapter for torque wrench.
Do not use sockets showing wear or cracks.
Replace fasteners with rounded corners.
To avoid damaging DTC: Never use checker with power off. Always turn ON
DTC so applied torque is being measured.
Do not press POWER while torque is applied.
Never use this checker to calibrate torque wrenches.
Do not use extensions, such as a pipe, on handle of wrench.
Check that DTC capacity matches or exceeds each application before
proceeding.
Verify calibration if dropped.
Never attempt to test an impact tool or pulse type tool on this checker.
Make sure ratchet direction lever is fully engaged in correct position.
Verify calibration of DTC if you know or suspect its capacity has been
exceeded.
Always adjust your stance to prevent a possible fall should something give
while checking torque wrench.
Do not attempt to recharge Alkaline cells.
Store DTC in dry place.
Remove batteries when storing checker unused for periods longer than 3
months.
WARNING Electrical Shock Hazard.
Electrical shock can cause injury. Do not use on live electrical circuits.
SAVE THESE INSTRUCTIONS
Disclaimer
Operation of DTC is not warranted in an EU member state if operating instructions are
not in that State’s language. Contact CDI Torque Products if a translation is needed.

2
Specifications
Socket Type
½” Female Square Drive
Display
DISPLAY TYPE: Dot Matrix LCD (192 x 65 Resolution)
VIEWING DIRECTION: 6:00
BACKLIGHT: WHITE (LED)
Sealed Button Pad
POWER - ON/OFF and torque re-zero
ENTER - measurement mode select and menu entry
UP –increments settings and menu navigation
DOWN - decrements settings and menu navigation
UNITS - units select (ft-lbs, in-lbs, Nm)
RECALL –Recalls last applied peak torque
Functions
Track - real time display of torque
Peak Hold –5 sec. flashing of peak torque on release of torque
First Peak –5 sec. flashing of peak torque after initial drop off in torque
Peak Torque Recall –5 sec. flashing display last peak torque measurement
Accuracy
Temperature: @ 22°C (72°F)
CW CCW
Torque: ±1% ±1% of reading, 10% to 100% of full scale
Dimensions: Length / Weight
DTC Range
TORQUE: (Display Range and Resolution as shown below)
Operating Temperature: 0°F to 130°F (-18°C to 54°C)
Storage Temperature: 0°F to 130°F (-18°C to 54°C)
Measurement Drift: TORQUE: +0.01% of reading per Degree C
Humidity: Up to 90% non-condensing
Battery: Three "AA" Alkaline Cells, up to 40 hours continuous operation
A/C Adapter (Not included) A/C Adapter transformer, Voltage Input: 90 to 240VAC, 50-60 Hz, 0.8A
P/N: (DTS8269) Voltage Output: 9VDC, Current 2.2A
D/C Cigarette Lighter Receptacle D/C Adapter Cigarette, Voltage Input: 12V
(Not Included) P/N: (3325-0320-01)Voltage Output: 12V, Current 5A
Default Auto Shut-off: After 5 minutes idle –(Adjustable, see Settings)
Model Length Width Depth Weight
2503-F-DTC 13.2 in. 4.75 in. 2.2 in. 4.9 lbs.
Model Square Drive ft-lb in-lbs Nm overload (ft-lb)
2503-F-DTC ½ in. 25.0-250.0 300-3000 34.0-339.0 312.5

3
User Instructions
Basic Functions (Quick Start)
0.0
1.PEAK FT-LBS
Figure 1
Install three fresh "AA" cells into battery holder.
DTC Power On Sequence
Note: Do not turn on DTC while torque wrench is mounted to checker, otherwise torque zero offset
will be incorrect and DTC will indicate a torque reading when torque is removed. If this occurs,
remove torque wrench from DTC and re-zero by momentarily pressing POWER qbutton.
1. Turn On DTC.
Momentarily press POWER qbutton. CDI logo is displayed followed by torque re-zeroing
screen. After re-zeroing, the torque screen is displayed.
2. Select Mode Of Operation.
Toggle between PEAK, 1.PEAK and TRACK by repeatedly pressing ENTER button.
oPEAK = Used to check Dial and or Electronic Torque Wrenches
o1.Peak = Used to check Click Style Torque Wrenches
oTrack = Can be used to check Dial and Electronic Torque Wrenches
3. Select Units Of Measure.
Toggle between IN-LBS, FT-LBS and NM by repeatedly pressing UNITS button.
4. Peak Torque Recall.
Recall last peak torque applied by pressing and holding RECALL R button.
Main Menu
Main menu displays DTCoperational information.
1. From torque measurement screen, press and hold ENTER button for 3 seconds.
2. Use UP /DOWN buttons to highlight menu selection then press ENTER button.
AUDIBLE ALERT
MODE SELECT, MENU ENTRY
AND ENTER BUTTON
INCREMENT
BUTTON
ON/OFF
AND
RE-ZERO
BUTTON
DECREMENT
BUTTON
PEAK TORQUE
RECALL BUTTON
UNITS BUTTON
TORQUE DISPLAY
BATTERY
CONDITION
½” x ⅜”
Socket Adapter
½” Female
Transducer Socket
½” Female
Cycling Socket

4
Menu Selections:
oEXIT - Exits Main menu and returns to torque screen.
oCYCLE COUNT - Displays torque cycle count screen.
oSETTINGS - Displays DTC settings menu.
oCALIBRATION –Displays password screen (see Calibration manual).
3. To exit Main menu and return to torque measurement screen, press ENTER button while
EXIT menu selection is highlighted.
Note: Sleep mode turns off the DTC to conserve battery power. Do not apply torque while in sleep
mode.
Note: Calibration menu is password protected. Contact the CDI Repair Center regarding Calibration.
0.00
1. PEAK FT-LB
EXIT
CYCLE COUNT
SETTINGS
CALIBRATION
ENTER
button
held
Measurement Screen
Main menu
Show Info Selection
EXIT
CYCLE COUNT
SETTINGS
CALIBRATION
Settings Menu Selection
Press
ENTER
button
EXIT
SHOW INFO
SLEEP TIME
LCD CONTRAST
Press
ENTER
button
CAL: 2014/01/01
CWOI: 0.00
CWOR: 35
CW1I: 250.10
CW1R: 15931
CCWOI: 0.00
CCWOR: 10
CCW1I: 250.10
CCW1R: -15870
TQZ: 18
OVR CNT: 0
VER: 1.0.0
Press
ENTER
Button
to EXIT
Show Info Screen
screen
Cycle Count Screen
EXIT
CYCLE COUNT
SETTINGS
CALIBRATION
Main Menu
Press
ENTER
button
COUNT: 12
CLEAR
EXIT
UP/DOWN
buttons
COUNT: 0
CLEAR
EXIT
Press
ENTER
button
Cycle Count Screen
Press
ENTER
button
to Exit
UP/DOWN
Buttons to
select from
20 to 80
EXIT
SHOW INFO
SLEEP TIME
LCD CONTRAST
CONTRAST: 40
CONTRAST: 80
Press
ENTER
button
LCD Contrast Selection
LCD Contrast Screen
LCD Contrast Screen
EXIT
SHOW INFO
SLEEP TIME
LCD CONTRAST
SLEEP TIME
5 MIN
EXIT
SLEEP TIME
8 HR
EXIT
Press
ENTER
button
UP/DOWN
Buttons to
select
from
2 min. to 8
hrs.
Press
ENTER
button
to Exit
Sleep Time Screen
Sleep Time selection
Sleep Time Screen

5
Battery Replacement
Replace with three "AA" cells only.
oDo not attempt to recharge alkaline cells.
oDo not mix different battery types.
oReplace all batteries at same time.
oStore DTC in dry place.
oRemove batteries when storing DTC unused longer than 3 months.
Note: When Replace Battery screen is displayed DTC will no longer operate until batteries are
replaced. Only POWER button functions which immediately turns off DTC.
Optional Power Adapters.
When A/C or D/C power
Adapters are used,
A plug symbol will appear
In LCD screen and checker
does not enter sleep mode.
Battery Compartment
Battery slide-out compartment
0.0
1. PEAK FT-LB
REPLACE BATTERY
REPLACE
BATTERY
LOW BATTERY
100%
BATTERY
LEVEL
50% BATTERY
LEVEL
LOW BATTERY
A/C Power
EXIT
CYCLE COUNT
SETTINGS
CALIBRATION
Press
ENTER
button
ENTER PASSWD
00 0 0 0
Press
ENTER
button
5x
INVALID ID PASSWD
PRESS TO EXIT
Press
ENTER
Button
to EXIT
Calibration Menu Selection
Enter Password Screen
Invalid Password Screen

6
DTC Orientation
Proper Use
oHave a solid balanced stance.
oPush torque wrench at center of handle.
oWhen torque wrench reaches audible click or buzz release torque wrench.
oPush torque wrench slowly and evenly.
CERTIFICATION
This DTC was calibrated at factory using torque calibration system that is traceable to National
Institute of Standards and Technology (N.I.S.T.). Testing parameters comply with ISO 6789:2003
and ASME B107:300-2010 (B107.29).
MAINTENANCE / SERVICE
Clean DTC by wiping with a damp cloth. DO NOT use solvents, thinners or carburetor cleaners.
DO NOT immerse in anything.
Service, repair and calibration are to be done by CDI Service Center only. Contact your
CDI Torque Products representative.
CALIBRATION
Contact your CDI sales representative for calibration services.
IMPORTANT! Calibration events are recorded in wrench memory which
provides evidence to void factory certification of compliance.
Horizontal Mounting
Clockwise Vertical Mounting
Counter Clockwise Vertical Mounting
Center Of Handle
Push torque wrench in this
direction for clockwise check
Push torque wrench in this
direction for counter
clockwise check

7
This page intentionally left blank.

8
This page intentionally left blank.

9
This page intentionally left blank.

10

19220 San Jose Ave.
City of Industry, CA 91748
Phone: 626-965-0668
Fax: 626-965-2410
Email: sales@cditorque.com
Website: www.cditorque.com
Made in USA with US and Global Components
20-3325-CDI REV. -
Snap-on Tools Company
Kenosha, WI 53141-1410 USA
Printed in USA
14-10
Table of contents
Other CDI TORQUE Measuring Instrument manuals