GALEO
Illuminated RF Keypad
INSTALLATION MANUEL
BERTA
Road barrier
INSTALLATION MANUAL EN
10 erone.com
N° Function Dip Pos Description
1Overhead door /
sliding gate
ON Overhead garage door ( 2 sec. of extra pressure after closing )
OFF Sliding gate
2Automatic
closure
ON Automatic reclosing ENABLED
OFF Automatic reclosing DISABLED
3Condominium
mode / step
ON Alternative button START (1-2) stops and inverts at closing. Disable stop
OFF Alternative button START (1-2) stops.
4Direction
inversion
ON Normal drive direction.
OFF Opposite drive direction.
5Contact safety
in opening
ON NC contacts (4-6), stop & invert for 2 sec on opening, stop & invert the
direction on closing
OFF NC contacts (4-6) stop the movement on opening, stops & inverts on
closing
6Flashing
function
ON Warning light blinking
OFF Warning light xed
7Slow down
ON slow down mode at the end of each manouvre ( opening and closing )
OFF No slow down : full torque
8Encoder ON Encoder input active
OFF Encoder input disabled
8] Dip-switch settings
1 2 3 4
5 6 7 8
1 2 3 4
1 2 3 4
1 2 3 4
5 6 7 8
5 6 7 8
5 6 7 8
NOTES
• Safety edge, connected on terminals 4 - 6. This contact protects opening and closing.
DIP 5 ON: When there is an obstacle, the motor stops and reverses for 2 sec.
DIP 5 OFF: When there is an obstacle motor STOP.
In both cases after the disengagement resumes the opening.
• Photocells, connected on terminals 5 - 6. This contact protects only in closing : when there is an obstacle
the motor STOP.
• Emergency Stop connected on terminals 6 -7 - The contact, if open, will causes the immediate stop of the
automation in any situation.