ICS Smart Indoor Repeater
CenRF Communications Limited www.cenrf.com Page 9 of 13
Screenshot of Downlink and Uplink Setting
Description of Basic Setting Parameters:
CH NUM: See the Specifications for the maximum number of channels supported by the overall
unit based on the practical environmental setting; Up and down the line frequency point linkage
(just Settings horizontal frequency point, ascending will automatically associated the
corresponding frequency point)
Gain: According to external isolation degree automatic Settings, the biggest gain 75 db
Output power: Module of the total output power, the default Settings for downlink 13 DBM, every
15 DBM, each channel power divide (total power divide to open each channel)
Attenuation: To set the overall unit’s gain attenuation
EN: Open and close the channel based on the number of channels used; Electromagnetic linkage
(will open channel after the uplink channel corresponding also open)
Description of Work Control Parameters:
Downlink: ON means that it is under normal operating condition;
OFF means that downlink is closed and there is no output signal from the module;
Uplink: ON means that it is under normal operating condition;
OFF means that downlink is closed and there is no output signal from the module;
ICS: ON means that the feedback inhibition function is enabled (the uplink and downlink of this
switch must be under the same condition, i.e. switch on or off simultaneously);
OFF means that the feedback inhibition function is disabled;
Up link Noise Suppression: Select Not Working;
ICS protect: Select Working.
Threshold(dB): Gain binding isolation degree value (suggest setting for 17)