CENTAUREA CentaurSlam Hornet Quick guide

1(16)
Instructions for Safe Use
(Certification N:o VTT 08 ATEX 066)
Thank you for choosing CentaurSlam Hornet® –portable work light for your job site. Purpose of this
manual is to provide you all the necessary safety and product information to conduct your job
conveniently and without any risks for health and safety.

2(16)
Contents
1. Introduction to CentaurSlam® Hornet..........................................................................................3
1.1 Technical data ...........................................................................................................................3
1.2 Certification of equipment..........................................................................................................4
1.3 Standard unit construction.........................................................................................................5
1.4 Quality guaranteed ....................................................................................................................6
1.4.1 General ...............................................................................................................................6
1.4.2 Individual testing reports.....................................................................................................6
2. Prior to use...................................................................................................................................7
2.1 Selection of right equipment......................................................................................................7
2.1.1 Intended purpose of equipment..........................................................................................7
2.1.2 Application of use (Zone XX) in accordance with equipment category..............................8
2.1.3 Explosion group (IIA, IIB or IIC) in accordance with Equipment group (IIA, IIB or IIC) ......8
2.1.4 Temperature class of the equipment..................................................................................8
2.1.5 Environmental criteria.........................................................................................................9
3. Operating instructions..................................................................................................................9
3.1 Personnel ..................................................................................................................................9
3.2 Visual inspection of CentaurSlam® Hornet...............................................................................9
3.3 Special attention on 2-pole use (24 V or 42 V) .......................................................................10
3.4 Connection to the supply.........................................................................................................10
3.4.1 Requirements for supply (electricity) ................................................................................10
3.5 Adding accessories to CentaurSlam® Hornet........................................................................11
3.6 Linking in series.......................................................................................................................11
4. Inspection & maintenance .........................................................................................................12
4.1 After use ..................................................................................................................................12
4.2 Maintenance............................................................................................................................13
4.3 Testing.....................................................................................................................................13
4.4 Repair report............................................................................................................................14
4.6 More information about the use of Electrical Apparatus for Explosive Gas Atmospheres......14
Helpdesk ...........................................................................................................................................16

3(16)
1. Introduction to CentaurSlam® Hornet
(Certification N:o VTT 08 ATEX 066)
This instruction manual guides you through the process of selecting and adopting CentaurSlam®
Hornet work light at your work site. The manual regards the following CentaurSlam® Hornet types:
1.1 Technical data
CentaurSlam® Hornet 1x18W (later CSH118)
CentaurSlam® Hornet 1x36W (later CSH136)
CentaurSlam® Hornet 2x36W (later CSH236)
CentaurSlam® Hornet Linear 2x18W (later CSHL218)
CentaurSlam® Hornet Linear 2x36W (later CSHL236)
Dimensions / mm
Product model
L
Ø
CentaurSlam®Hornet 1x18W
335
115
CentaurSlam®Hornet 1x36W A
540
115
CentaurSlam®Hornet 1x36W C
580
115
CentaurSlam®Hornet 2x36W
865
115
CentaurSlam®Hornet Linear 2x18W
575
115
CentaurSlam®Hornet Linear 2x36W
1020
115

4(16)
1.2 Certification of equipment
The CentaurSlam® Hornet–series has been designed, tested and certified (according to ATEX) for
portable use. There is no “X” –mark in the certificate for special conditions of safe use of the
equipment. The equipment is to used properly and according to its ratings, documentation and
local applicable laws. Local, national certificates of these units may exist outside the region of EU.
The aforementioned CentaurSlam® Hornet–types are certified as follows. You may find brief
explanation of certificate beneath:
CE0537 II 2 GD Ex emb IIC T3 Gb
Ex t IIIC T 90 °C Db
IP 66
CE0537 = Valid production quality system approved and notified by VTT (Finnish Notified Body,
listed by EC)
= Certified for explosion hazardous areas
II = Certified for use in areas excluding mines
2 = Equipment category (suitable for Zone 1&21 and Zone 2&22)
G= Certification taking account explosion hazardous GASES
D= Certification taking account explosion hazardous DUSTS
Explanation of marking for explosion hazardous area due to Gases (Ex emb IIC T3 Gb) :
Ex = Certified for use in explosion hazardous areas
e= Explosion protection method increased safety (of certain components)
mb = Explosion protection method encapsulation (encapsulating ignition sources e.g. electronic
ballast)
IIC= Equipment group (including explosion hazardous areas of IIA, IIB and IIC gases)
T3 = Maximum inside temperature of the unit is 200 °C (within the ambient temperature range of
-20°C - +40°C)
Gb = Explosion Protection Level (EPL) marking for “HIGH” level of protection. Equipment for
explosive GAS atmospheres, which is not a source of ignition in normal operation or during
expected malfunctions.

5(16)
Explanation of marking for explosion hazardous area due to Dusts (Ex t IIIC T 90 °C Db):
Ex = Certified for use in explosion-hazardous areas
t= Explosion protection method “protection by enclosure”
IIIC = Equipment group for conductive dusts (including IIIA, IIIB and IIIC dusts)
T 90 C = Maximum OUTSIDE surface temperature of the unit is 90 °C (within the ambient
temperature range of -20°C - +40°C)
Db = Explosion Protection Level (EPL) marking for “HIGH” level of protection. Equipment for
explosive DUST atmospheres, which is not a source of ignition in normal operation or during
expected malfunctions
1.3 Standard unit construction
The following list familiarizes you with some common unit features important to recognize.
End parts: Flexible, plastic-made end parts ensure shock-absorbing and harmless contact to
sensitive and hard surface in case the luminary drops to the ground even from high position. Light
construction affects the total weight of the unit itself.
Transparent PC –tube: Polycarbonate tube, being durable, flexible and lightweight plastic, brings
advantage for use. Unique antistatic treatment allows the use of PC in explosion hazardous areas.
Aluminium frame: Nearly all CentaurSlam® Hornet–units are based on use of solid but flexible
aluminium frame. Components are tightened with screws on it, making the unit tough and durable
in severe conditions. Moreover, the frame derives excessive heat out from the luminary thereby
extending lifetime of the unit.
Electronic ballast: The ballasts are independent from each others (CSH236 and CSHL236).
Under failure of one ballast, the other still continues operating. Low-voltage protection (smart-
feature) brings reliability and convenience for use, especially when operating with transformers or
with long cables.
Compact fluorescent lamp (CFL): CFL are standard types but undergo special spark-prevention
process (encapsulation) in the factory. They also have a component certificate. Light colour is cool-
white and colour temperature 4000 K –not blinding the user’s eyes but bringing appropriate help
for the user to complete his job.
Cable: Standard cable of the CentaurSlam® Hornet–series is H07BQ-F. This cable has
polyurethane (PUR) outer sleeve. PUR withstands well chemicals as well mechanical wearing.

6(16)
However, the user has an option to specify cable type in accordance with work site requirements of
own.
Socket: Optional in-built sockets (receptacles) for linking the CentaurSlam® Hornet units in series
(apart from CSH118)
Other common accessories (optional):
Antistatic protective film for PC tube against chemical splashes and other substances
Adjustable hanging straps for light fixing.
To view options on accessories, please visit http://www.centaurea.fi for further study or call/fax
+358 6 4212 400 / +358 6 4140 631.
1.4 Quality guaranteed
1.4.1 General
The CentaurSlam® Hornet–series is designed, certified, manufactured and tested under ISO
9001:2008 quality system as well as additional requirements of the Directive 94/9/EC (ATEX). The
CentaurSlam® Hornet–series is designed and tested according to the latest directives and
standards. The referred directives and standards of the production date in case are stated on the
Declaration of Conformity included in the delivery.
1.4.2 Individual testing reports
Each CentaurSlam®–unit has its own individual serial number and is provided with an original,
individual testing report when leaving the factory. The year of manufacture is specified on the type
label of the equipment. Following tests have been done for CentaurSlam® Hornet–units according
to standards relating to portable luminaries for explosion hazardous area. The Declaration of
Conformity is specifying the relevant standards. The testing report which is included in the delivery
specifies the results of the factory tests for that particular unit. The testing report typically specifies
the following tests:
PE –resistance test
The purpose of this test is to measure persistence of earth conductor.

7(16)
Vital test for electrical safety as well as explosion safety because of e.g static electricity control.
The test current is 10 A (current) and the overall resistance should not exceed 0,5 ohm.
High voltage test (electrical strength)
The purpose of this test is to measure leakage current trough insulation. Vital test for revealing
broken components or similar failures which can not be identified visually.
Testing voltage applied is 2130VDC. Maximum leakage current is 5mA.
Test of expected use of equipment
The luminary is subjected to shaking and vibration –to see that all the internal wires are properly
attached and components are not loose.
Operational test of luminaire and accessories
The unit is plugged-in and checked that it is working properly after all accomplished tests above.
Visual inspection
A final check to see everything is fine (screws attached properly, wires connected and required
markings attached).
2. Prior to use
2.1 Selection of right equipment
You need to be sure that the equipment you intend to take into explosion-hazardous area matches
up with the zone classification and other safety requirements related. At least the following points
should be notified prior to use:
2.1.1 Intended purpose of equipment
Please keep in mind what the actual application of equipment is. For example in case the
equipment is to be moved when connected to the supply it needs to be designed for that purpose.
If the certification is mentioning “portable”it means that the equipment is suitable and tested for
portable use. If the certification does not mention portable it means that the equipment shall not be
moved when it is in operation (reliable fixing of equipment).

8(16)
CentaurSlam® -units are designed and tested for portable use.
2.1.2 Application of use (Zone XX) in accordance with equipment category
Operator has the best knowledge of area classification at his site. To help the operators’ selection
of equipment the certification is describing the equipment category. For explosion hazardous areas
there are three equipment categories.
Category 1 product is suitable for use in Zones 0, 1 and 2 / (20, 21 and 22)
Category 2 product is suitable for use in Zones 1 and 2 / (21 and 22)
Category 3 product is suitable for use in Zones 2 / (22)
CentaurSlam® -units mentioned in this instruction fall into Category 2 equipment.
2.1.3 Explosion group (IIA, IIB or IIC) in accordance with Equipment group (IIA, IIB
or IIC)
This information is vital because the substances require different amount of energy to be ignited.
Safety requirements for equipment are not the same for different substances (e.g. static electricity
requirements).Therefore making the selection easier the gases are divided to three different groups
(IIA, IIB and IIC). Further information about the substances can be found from EN 60079-20-1
(Data for flammable gases and vapours, relating to the use of electrical apparatus).
CentaurSlam® -units mentioned in this instruction are Equipment group IIC.
2.1.4 Temperature class of the equipment
Please observe the Ignition Temperature (IT) of the substance creating the explosion hazard at
your site. Select the equipment based on IT of the substance. The temperature of the equipment
must be lower than IT. The highest temperature of the equipment is specified by using
Temperature Classes T1 to T6.
Example:
Petroleum ignition temperature is approximately 250 Celsius Maximum allowed temperature
class of the equipment is T3 (< 200° C)
CentaurSlam® -units mentioned in this instruction are Temperature Class T3 (GASES)
CentaurSlam® -units mentioned in this instruction maximum surface temperature of 90⁰C (DUSTS)

9(16)
2.1.5 Environmental criteria
Please observe the ambient temperature of the application in use because certification is valid for
temperatures between –20°C --- + 40°C. Some CentaurSlam® HORNET luminaries are certified
for temperatures between –40°C --- + 40°C. Please see type label of the product for further data. If
the equipment is used in other temperatures than mentioned the safety can not be guaranteed.
Selection and use of equipment is always under the responsibility of the
operator. Please note that all of the aforementioned criteria are to be fulfilled
when selecting the equipment.
Please do not take any unnecessary risks.
3. Operating instructions
3.1 Personnel
The use of the equipment is to be controlled and accepted by the operator. The personnel using
the unit have to be authorized by the operator or his representative. In case of further training of
using the equipment please contact the local supplier of this equipment.
3.2 Visual Inspection of CentaurSlam® Hornet
As for all equipment to be used inside explosion hazardous area it is recommended that before
taking the unit into Ex –area, a visual re-inspection on the unit was taken and an analysis made
that the unit is un-damaged (e.g. any part or wires are loose damaged or disconnected)
In case faults or defects on the unit are noticed, it is prohibited to take such a unit into Ex –area
until corrective actions have been made.

10(16)
3.3 Special Attention on 2-pole use (24 V or 42 V)
Certain CentaurSlam® Hornet -units are designed to be used together with step-down
transformers. Using CentaurSlam® Hornet -unit with transformers of 2-pole socket outlets (without
earthing / bonding) imposes certain extra requirements for the unit itself. All the external metal and
aluminium parts of the CentaurSlam® Hornet are replaced by the manufacturer with plastic parts or
equipped with plastic covers in order to avoid electrostatic charging and a consequent risk of
explosion. This process can only be done by manufacturer because the certification of the product.
Please inform us about your requirement for 2-pole use when placing the order. Products originally
manufactured for 3-pole use can not be modified later for 2-pole use.
Note! Lack of equipotential bonding may cause danger in Ex –area, therefore please pay special
attention to all installations of yours involving metallic parts. Static charging is especially noted on
standards referring to installations in explosion hazardous areas (e.g. EN 60079-14).
3.4 Connection to the supply
It is recommended that the unit is first connected to the mains / transformer before entering the
explosion-hazardous area. Potential equalization should be arranged by the operator prior entering
explosion hazardous area.
CentaurSlam® Hornet-units with 2-pole supply (without bonding connection) can be taken to
explosion hazardous area without connecting it to the supply first.
3.4.1 Requirements for supply (electricity)
The following main requirements should be taken into account:
Supply voltage: Variation may be maximum +/- 6% from the value stated in the unit type label.
Current: Maximum current of the system is 16 A.
Frequency: Standard 50 Hz if not otherwise stated in the type label.
Fuse protection: The supply has a fuse with a breaking capacity of at least 1500 A
Earth Leakage Circuit Breaker (ELCB): It is recommended to use a supply with 30 mA ELCB.
Please observe the type label for further data.

11(16)
3.5 Adding accessories to CentaurSlam® Hornet
Centaurea provides a number of different accessories but in case you afterwards want to add
accessories of your own for the CentaurSlam® Hornet –unit, please note the following points:
1. The user is fully responsible for the use of the equipment including service and
maintenance
2. In case of adding accessories the following is mandatory
a. The construction of the certified unit shall not change
b. The IP –class of the unit shall not decrease
3. The static electricity is taken account (e.g. electrostatic bonding)
In case you do not want to do your own risk assessment for the accessories please view the whole
range of accessories at http://www.centaurea.fi
3.6 Linking in Series
Certain CentaurSlam® Hornet-units may be equipped with Ex –certified socket in the factory.
Sockets are considered as one option so they are added to the unit upon customer’s special
request.
In-built sockets are recommended when the illuminated area is notably large, complex or not
enough wiring points are available. Linking the units in series save time, amount of cable and
provide an opportunity to build a chain of lights to provide enough illumination in the darkness.
When linking CentaurSlam® Hornet –lights together, please take the following steps:
1) If using transformer, ensure its condition and capability to supply correct amount of voltage
and current
2) Connect the first unit outside the Ex –area
3) Then connect the other luminaries to each other one by one
4) The in-built socket is only for chaining CentaurSlam® Hornet units.
5) Fix them with accessories you have selected
6) Take the chain into Ex –area

12(16)
Amount of lights which may be connected with each other depends on the supply voltage. Here
you may see general guide-lines for linking with 5 m 3x1.5mm2(or 3x2.5mm2) cable each:
Supply voltage
Recommended
max. load
Type of luminaire
Number of luminaries in
series
230 V
2000 W
CSH236 (72 W)
27
110 V
1000 W
CSH236 (72 W)
13
42 V
500 W
CSH236 (72 W)
6
24 V
290 W
CSH236 (72 W)
4
12 V
150 W
CSHL218 (36 W)
4
The CentaurSlam® Hornet ballast protects itself against excessive voltage drops (numerous
linking) by switching itself off. If too many units are connected to the chain, some units of the chain
will switch off. You may start up by unplugging the last units on the line.
Voltage peaks are more harmful and may damage the ballast permanently when subjected to
excessive peaks continuously.
If fluorescent tubes are flickering when the units are chained up, it may be due to excessive linking.
This may shorten notably the lifetime of fluorescent tube. Unplug the last unit on the line to ensure
proper function of the unit.
4. Inspection & Maintenance
4.1 After Use
Take the following steps after the CentaurSlam® Hornet –unit has been taken out from Ex –area:
1) Clean the unit with a damp cloth (do not use detergents or solvents)
2) Change the anti-static film if only little light comes through it or it is damaged
3) Have a visual check on the unit (condition of cable, PC –tube, tightness of parts)
4) Let the unit dry in open air

13(16)
4.2 Maintenance
The following procedure should be taken in case the CentaurSlam® Hornet unit needs to be
repaired:
1) Maintenance may be carried out only outside Ex –area
2) Person responsible for maintenance should have been trained the basics of explosion-
protection as well electricity
3) Only original spare parts from the manufacturer should be used. Please note that there are
no components in this unit which can be repaired by using glue, silicone or any other
similar method.
4) The green colour on transparent parts of CentaurSlam® Hornet may be damaged because
of external affects like solvents or chemicals or mechanical stress. In case the green colour
has disappeared in one area greater than 100 cm2the part has to be changed. The surface
resistance of the transparent parts has to be between 1 MΩ - 1 GΩ.
5) Maintenance instructions with exploded-view diagram and spare parts list are available at
your local distributor and the manufacturer. Please, when requesting maintenance
instructions with exploded-view diagrams, include the model and serial number of the
product.
4.3 Testing
Tests are to be done according to EN 60079-19 until returning the repaired unit back to operation.
Below mentioned tests shall be done in addition to the tests specified in EN 60079-19
PE –resistance test
High-voltage test (500 VDC between Phase& Neutral against P/E conductor)
Operational test
Test of expected use (vibrations, shaking)
Proper testing ensure safe operation of repaired equipment.

14(16)
4.4 Repair report
The operator is responsible for keeping up to date record of the condition of his equipment (EN
60079-14). Ensuring the availability of this important information each repair procedure should be
written down in repair report according to EN 60079-19.
This report should reveal at least:
Person who conducted the maintenance
Date of maintenance
Procedure of maintenance
Signature of person responsible accepting the maintenance
4.6 More information about the use of Electrical Apparatus for Explosive Gas
Atmospheres
Please observe the requirements of the valid standards of the day. Please study at least the
following standards:
EN 60079-14 (Electrical installations in hazardous areas)
EN 60079-10 (Classification of hazardous areas)
EN 60079-17 (Inspection and maintenance of electrical installations in hazardous areas)
EN 60079-19 (Repair and overhaul for apparatus used in potentially explosive atmospheres)

15(16)
Notes:
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
This manual suits for next models
6
Table of contents
Popular Lighting Equipment manuals by other brands

O.N
O.N 23.8757.41 user manual

WHITECROFT LIGHTING
WHITECROFT LIGHTING COM 9 Installation instruction

Lithonia Lighting
Lithonia Lighting ELU 4 installation instructions

Lena Lighting
Lena Lighting UP LED Installation instruction

SG
SG Stripline TW quick start guide

Eaton
Eaton Lumark Axcent installation instructions

thomann
thomann STAIRVILLE Hz-200 Compact Hazer DMX user manual

Cooper Lighting
Cooper Lighting PROfile AR60S Specification sheet

LTH
LTH Square LED Pro Vario Softlight Single user manual

Qtx
Qtx Wash & Beam user manual

Lena Lighting
Lena Lighting MAGNUM MULTIBATTERY XS Installation instruction

urbansolar
urbansolar RMS-F Series Installation & operation manual