Chainway C66 User manual

SHENZHEN CHAINWAY INFORMATION TECHNOLOGY CO., LTD
C66 UHF User Manual

1
Statement
by ShenZhenChainway Information Technology Co., Ltd. All rights
reserved.
No part of this publication may be reproduced or used in any form, or
by any electrical or mechanical means, without permission written
from Chainway. This includes electronic or mechanical means, such
as photocopying, recording, or information storage and retrieval
systems. The material in this manual is subject to change without
notice.The software is provided strictly on an “as is” basis. All
software, including firmware, furnished to the user is on a licensed
basis. Chainway grants to the user a non-transferable and non-
exclusive license to use each software or firmware program delivered
hereunder (licensed program). Except as noted below, such license
may not be assigned, sublicensed, or otherwise transferred by the
user without prior written consent of Chainway. No right to copy a
licensed program in whole or in part is granted, except as permitted
under copyright law. The user shall not modify, merge, or incorporate
any form or portion of a licensed program with other program material,
create a derivative work from a licensed program, or use a licensed
program in a network without written permission from Chainway.
Chainway reserves the right to make changes to any software or
product to improve reliability, function, or design. Chainway does not
assume any product liability arising out of, or in connection with, the
application or use of any product, circuit, or application described
herein.
No license is granted, either expressly or by implication, estoppel, or
otherwise under any Chainway intellectual property rights. An implied
license only exists for equipment, circuits, and subsystems contained
in Chainway products.

2
Statement.......................................................................................... 1
Chapter 1 Product Intro.....................................................................3
1.1 Intro .....................................................................................3
1.2 Brief.....................................................................................4
1.3 Device installation................................................................ 5
Chapter 2 Module Interface Definition...............................................6
2.1 C61 UHF.................................................................................. 6
2.2 C61 UHF.................................................................................. 7
2.3 Parameter Setup......................................................................8
Chapter 3 Read and Write EPC ...................................................... 15
3.1 Read EPC.............................................................................. 15
3.2 Read & Write Tags ................................................................ 16
3.3 Lock UHF Tag........................................................................ 20
3.4 UDP-ReceiveEPC.................................................................. 21
3.5 Others.................................................................................... 22

3
Chapter 1 Product Intro
1.1 Intro
Chainway C61 UHF is a single channel UHF RFID reader module
with high performance. It can be integrated in mobile UHF RFID
readers, fixed UHF RFID readers, UHF card readers, integrated RFID
readers and etc. With high integration level, this reliable module is
small in size, low in power consumption. It is also resistant to
electromagnetic interference and good at heat dispersion. All make it
to absolutely satisfy needs of all environments. The module appeals
to challenging industries like warehousing, logistics, apparel,
production lines and such.

4
1.2 Brief
C61 module can be adopted with multiple types of antennas with
output powers as 5dBi, 9dBi, 12dBi. The port is SMA and
development board, Windows SDK and demos are provided.

5
1.3 Device installation
C61 can be connected as Pic.2. PC can connect with
development board by cable. Single C61 module can connect
with different amounts of antennas according to different
models.
Pic.2

6
Chapter 2 Module Interface Definition
2.1 C61 UHF

7
2.2 C61 UHF

8
2.3 Parameter Setup
Double click UHFAPP.exe to enter software, and connect with device
through serial port line. Select Mode to “SerialPort”, select COM to
according serial port on PC. Click “Open” to connect with device,
initiation page is as follows:
If RJ45 has been used as connection, communication Mode needs to
be selected as “network” and input IP address and port number
(default IP address is 192.168.99.202, Port is 8888.) Then click
“Open” to connect PC and device. After PC and device have been
connected, the status page is as follows:

9

10
After device has connected with PC, the parameters on interface will
be empty. Click “Get” on each option to collect device parameters.
Click “Set” on the page, user can adjust necessary parameters, some
parameters are default values.
Output power can be set in range of 5 dBm to 30 dBm as following
picture, after select value, click “Set” button. If “Save” has been
selected, current parameters will be saved after power off device.
Set regions:

11
Set RFLink:
Set continuous wave:
There are two work modes can be selected, “command mode” and
“auto mode”.
Under “command mode”, user could collect tag data in “Read EPC”
page, click “Start” to send command to device on PC, click “Stop” to
stop collecting tag data.
Under “auto mode”, user could collect tag data in “UDP-ReceiveEPC”
page, click “Start” to receive data, click “Stop” to stop receiving data.
After selecting “auto mode”, the device needs to be restarted.

12
Set IP address and make sure PC and device have used in same
segment. For example, if IP address of PC is 192.168.1.109, mask is
255.255.255.0, the device IP address can be set to 192.168.1.201,
port number doesn’t need to be changed.
Set antenna connection, there are 4 I/O ports on device and have
been marked as ANT1, ANT2, ANT3, ANT4. User needs to select
antenna which has been connected and click “set”.
Set destination IP address and port number, destination IP address is
the IP address which used for reading tag data under “auto mode”.

13
Set FastID:
Set TagFocus:
Set protective temp. It means to setup highest operating temperature
of UHF module:
Set EPC and TID:

14
Reset, click “Reset” button to restore device to default value. After
reset, user needs to click “Close” and “Open” to reconnect the device.
Set Buzzer, click “Open” to switch on buzzer function, device will play
notification sound when reading tags.
Set Gen2, this parameter needs to be adjusted by actual
requirements.

15
Chapter 3 Read and Write EPC
3.1 Read EPC
Click “ReadEPC” in menu to enter EPC page, click “Start” to read
tags, click “Stop” to stop reading. The EPC, RSSI, Count number and
ANT number (antenna channel) will be recorded in window as
following pic:
User could enter data in “Filter” to filter EPC of special tags, the
maximum filter DL is 96 bits. User needs to setup data, initial address,
data length and click “Set”. After filtered data has been set, the device
will read and search for the tag which has been filtered.
For example: enter 16 01 in “Data”, initial address data length is
32(bit), length is 16(bit), select EPC in “bank”, click “Set” and click
“Start” to start scanning tags which the address start at 16 01:

16
3.2 Read & Write Tags
Click “ReadWriteTag” to enter its page, TID area can be read only,
RESERVED, EPC and USER areas can be read and written.

17
Click one option in “Read-write” window to enter tag reading mode,
EPC will be automatically copied into “Data” block in filter, default
option is EPC reading, click “Read” to read 12 bytes of EPC area.

18
For “RESERVED” area, user could read 4 words at maximum,
previous 2 words are password of KILL function, last 2 words are
access passwords:
Read TID area:

19
Read USER area:
Data could be written in EPC, RESERVED and USER areas, select
according areas and input initial address, length, input data into “Data”
window and click “Write” to write data into according areas.
Other manuals for C66
2
This manual suits for next models
1
Table of contents
Other Chainway RFID System manuals