3
APPLICATION
This operator includes a number of features that will provide years
of reliable and safe operation.
FEATURES:
• Supports both monitored and non-monitored entrapment
protection devices: Entrapment protection devices detect
obstructions in the door's path and automatically reverse a
closing door.
• Radio receiver: A factory installed radio receiver allows remote
controls, keyless entries and other remote command devices to
be programmed to the operator.
• Timer-to-Close: The Timer-to-Close feature allows the door to
automatically close after a preset time (only available with B2
wiring and a monitored entrapment protection device).
• Wiring Types: The functionality of the operator is based on the
wiring type. The operator is shipped from the factory in standard
C2 wiring type (factory default). Some wiring types will require
an optional monitored entrapment protection device. Refer to
Basic Programming Section for descriptions of wiring types,
requirements and programming.
SAFETY INFORMATION
SECTIONAL
DOOR
SQ. FT
MAXIMUM DOOR AREA AND MAXIMUM DOOR HEIGHT 14 FEET
--- 24 ga., 22 ga. Steel 20 ga. Steel 16 ga. Steel ---
Fiberglass Aluminum Doors Wood Doors --- ---
--- --- 24 ga. Steel Insulated 20 ga. Steel Insulated 16 ga. Steel Insulated
310 260 225 150 100
NOTE: Actual track length will exceed door height by 2 feet.
To reduce the risk of SEVERE INJURY or DEATH:
IMPORTANT INSTALLATION INSTRUCTIONS
1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND
INSTRUCTIONS.
2. Install door operator ONLY on properly balanced and
lubricated door. An improperly balanced door may not
reverse when required and could result in SEVERE INJURY
or DEATH.
3. ALL repairs to cables, spring assemblies and other hardware
MUST be made by a trained door systems technician BEFORE
installing operator.
4. Disable ALL locks and remove ALL ropes connected to door
BEFORE installing operator to avoid entanglement.
5. Install door operator 8 feet (2.44 m) or more above floor.
6. NEVER connect door operator to power source until
instructed to do so.
7. NEVER wear watches, rings or loose clothing while installing
or servicing operator. They could be caught in door or
operator mechanisms.
8. Install control station:
• within sight of the door.
• out of reach of children at minimum height of
5 feet (1.5 m).
• away from ALL moving parts of the door.
9. Install the control station far enough from the door to
prevent the user from coming in contact with the door while
operating the controls.
10. Install the entrapment warning placard on wall next to the
control station in a prominent location that is visible from
the door.
11. Place manual release/safety reverse test label in plain view
on inside of door.
12. Upon completion of installation, test entrapment protection
device.
13. SAVE THESE INSTRUCTIONS.
WARNING