logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Chamberlain
  6. •
  7. Portable Generator
  8. •
  9. Chamberlain 580LM User manual

Chamberlain 580LM User manual

This manual suits for next models

1

Other Chamberlain Portable Generator manuals

Chamberlain LiftMaster PROFESSIONAL 475LM User manual

Chamberlain

Chamberlain LiftMaster PROFESSIONAL 475LM User manual

Chamberlain 475M User manual

Chamberlain

Chamberlain 475M User manual

Chamberlain 580LM User manual

Chamberlain

Chamberlain 580LM User manual

Chamberlain A7008890 User manual

Chamberlain

Chamberlain A7008890 User manual

Chamberlain LiftMaster Professional 475M User manual

Chamberlain

Chamberlain LiftMaster Professional 475M User manual

Popular Portable Generator manuals by other brands

Kohler 20EORZ Operation

Kohler

Kohler 20EORZ Operation

Powerhorse 83171 owner's manual

Powerhorse

Powerhorse 83171 owner's manual

HURST ML-630-SI instruction manual

HURST

HURST ML-630-SI instruction manual

ETQ TG4000 owner's manual

ETQ

ETQ TG4000 owner's manual

Briggs & Stratton 40265 Illustrated parts list

Briggs & Stratton

Briggs & Stratton 40265 Illustrated parts list

evertz 7700 Series manual

evertz

evertz 7700 Series manual

Firefly Cygnus CYG2400/460/24 user manual

Firefly

Firefly Cygnus CYG2400/460/24 user manual

Owon Waveform Generator manual

Owon

Owon Waveform Generator manual

Draper PG950S Instructions for

Draper

Draper PG950S Instructions for

SDMO SH 4000 Generating set user and maintenance manual

SDMO

SDMO SH 4000 Generating set user and maintenance manual

EINHELL STE 5500 operating instructions

EINHELL

EINHELL STE 5500 operating instructions

Wanco WI3000P Operator's manual

Wanco

Wanco WI3000P Operator's manual

Full Boar FBT-3300 instruction manual

Full Boar

Full Boar FBT-3300 instruction manual

Dwyer Instruments ASG manual

Dwyer Instruments

Dwyer Instruments ASG manual

Westinghouse WH1000i Series owner's manual

Westinghouse

Westinghouse WH1000i Series owner's manual

Wallenstein GF5000A manual

Wallenstein

Wallenstein GF5000A manual

Leroy-Somer LSA 49.1 Installation and Maintenance

Leroy-Somer

Leroy-Somer LSA 49.1 Installation and Maintenance

Yamakoyo SH2900DX owner's manual

Yamakoyo

Yamakoyo SH2900DX owner's manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

4-6
4-6
3
9
2
7
COM 24V
8
To prevent possible SERIOUS INJURY or DEATH from electrocution
or fire:
• Disconnect power to opener BEFORE proceeding.
• NEVER use an extension cord, 2-wire adapter, or change plug in
any way to make it fit outlet. Be sure the opener is grounded.
WARNING
Models 580LM & 580LMC
Residential Jackshaft Opener Alternate
Power System Accessory
Disconnect all power to the opener if already installed.
Disconnect the Standby Power Unit®from the opener if it is
installed.
Determine mounting location for the interface within
3' (.9 m) of opener. Mount and secure with screws and
anchors.
Plug interface into opener.
Position transformer within 1' (.3 m) of outlet, secure with
screws and anchors.
NOTE: If transformer is being secured to ceiling, the
transformer must be secured to a ceiling joist.
Separate low voltage wires. One end of the wire is prepared
for convenience. Cut wire to appropriate length and strip
7/16" (11 mm) of insulation from the end of the wire.
Use one of the stripped wires to connect COM screw
terminals on the interface and transformer. Use the other
stripped wire to connect 24V screw terminals. (Polarity is
not important.)
Before permanently mounting, reduce slack in cord. Secure
with insulated staples.
Use cable tie to bind power cord from opener. Be sure to
keep power cord away from rail and out of the reach of
children.
Plug transformer into the outlet. To reduce the risk of electric
shock, your garage door opener has a grounding type plug
with a third grounding pin. This plug will only fit into a
grounding type outlet. If the plug doesn’t fit into the outlet
you have, contact a qualified electrician to install the proper
outlet.
NOTE: Opener may operate at a slower speed while using
this device.
Connect to Standby Power Unit®(SPU)
(Not Provided) (Figure 2)
Connect the SPU connector from the SPU to the interface.
NOTE: If connecting to a standby power unit, the interface and
SPU must be within 3' (.9 m) of each other.
Transformer (1)
Interface (1)
Anchor (8)
Screws (8)
Cable Tie (1)
Low Voltage Wire 35'
Insulated Staples (30)
Carton Inventory
1
2
3
4
5
6
7
8
9
Installation (Figure 1)
Figure 1
Figure 2
NOTE: For use only with Residential Jackshaft Openers.
NOTE: If the Smart Control Panel is showing the message
“Battery Back-up enabled” or the LCD Backlight is not on under
power from the Alternate Power System contact service at
1-800-528-9131.
Optional Low Voltage Wire 50'
(Not Shown) 41A6669
For more information, please visit www.devancocanada.com or call toll free at 855-931-3334
HOW TO ORDER REPAIR PARTS
DEVANCO CANADA
19192 HAY ROAD, UNIT Q
SUMMERSTOWN, ON K0C 2E0
TOLL FREE: 855-931-3334
www.devancocanada.com
WHEN ORDERING REPAIR PARTS
PLEASE SUPPLY THE FOLLOWING INFORMATION:
3PART NUMBER
3DESCRIPTION
3MODEL NUMBER