100592 - 6250W DUAL FUEL GENERATOR
VOPERATION
19
Move the generator to an open, outdoor area and point the
exhaust away from people and buildings. Once relocated to a safe
area, the generator can be restarted, and the proper electrical
connections made. Introduce fresh air and ventilate the location
where the generator shut off.
When starting, the red and yellow LED will blink ten (10) times
simultaneously to indicate the LED is working.
NOTICE
This blinking does not indicate CO Shield is working, as CO
Shield is working at all times the generator is running. Also,
the LED will not blink (10) times if the generator was restarted
within 1 minute after it was manually shut off. This does not
occur if generator shut off from a high CO event.
If CO Shield system experiences a fault and no longer provides
protection, the generator is shutoff automatically and the yellow
LED light will blink for at least five (5) minutes to notify you of the
fault.
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
SERVICE
REALICE UN SERVICIO
SERVICE
REALICE UN SERVICIO
Call our Technical Support Team at 1-877-338-0999 for repair.
The generator can be restarted, but will continue to shutoff.
CO Shield will detect the accumulation of carbon monoxide from
other fuel burning sources such as engine powered tools, or
propane heaters used in the area of operation. If another generator
is used and the exhaust is pointed at a CO Shield equipped
generator, the CO Shield may initiate a shutoff due to rising carbon
monoxide levels. This is not a fault. Hazardous carbon monoxide
has been detected. You must take action to move and direct the
equipment to better dissipate carbon monoxide far away from
people or buildings.
WARNING
Tampering with CO Shield®could result in a hazardous
condition. Removing the CO Shield module will not allow the
generator to start.
Generator Location
NEVER operate the generator inside any building, including
garages, basements, crawlspaces and sheds, enclosure or
compartment, including the generator compartment of a
recreational vehicle. Please consult your local authority. In
some areas, generators must be registered with the local utility.
Generators used at construction sites may be subject to additional
rules and regulations. Generators should be on a flat, level surface
at all times. (Even while not in operation) Generators must have
at least 5 ft. (1.5 m) of clearance from all combustible material.
In addition to clearance from all combustible material, generators
must also have at least 3 ft. (91.4 cm) of clearance on all sides to
allow for adequate cooling, maintenance and servicing. Generators
should never be started or operated in the back of a SUV, camper,
trailer, in the bed of a truck (regular, flat or otherwise), under
staircases/stairwells, next to walls or buildings, or in any other
location that will not allow for adequate cooling of the generator
and/or the muffler. DO NOT contain generators during operation.
Allow generators to properly cool before transport or storage.
Place the generator in a well-ventilated area. DO NOT place the
generator near vents or intakes where exhaust fumes could be
drawn into occupied or confined spaces. Carefully consider wind
and air currents when positioning generator.
Failure to follow proper safety precautions may void
manufacturer’s warranty.
WARNING
Do not operate or store the generator in rain, snow, or wet
weather.
Using a generator or electrical appliance in wet conditions,
such as rain or snow, or near a pool or sprinkler system,
or when your hands are wet, could result in electrocution.
WARNING
During operation the muffler and exhaust fumes will become
hot. If adequate cooling and breathing space are not supplied,
or if the generator is blocked or enclosed, temperatures can
become extremely heated and may lead to fire.