VIDEO DOOR ENTRY PANEL WITH KEYPAD USER’S MANUAL | 1/3
CHANNEL SAFETY SYSTEMS t: 0845 884 7000 | w: www.channelsafety.co.uk
Adding User Codes
1. Enter programming mode.
2. Enter a 2 digit user reference number (01-40).
3. Enter the 4 digit user code for the chosen user reference. If the chosen code is already in use the unit will emit a
long tone followed by two beeps. If the code is permitted then a two beep conrmation tone will sound.
4. Codes entered against user references 31-40 will latch the lock/relay open until the code is re-entered.
(commonly used for deliveries)
5. To enter further user codes repeat from step 2. To exit the programming mode press the key.
Deleting user codes
1. Enter programming mode.
2. Enter the 2 digit reference number (01-40) to be deleted, a two beep conrmation will be heard.
3. Press the key to delete user reference. A three beep conrmation tone will be heard.
4. To delete further user codes repeat from step 2. To exit the programming mode press the key.
Deleting a user code from an unknown user reference
1. Enter programming mode.
2. Press the key, the red LED remains on.
3. Enter the 4 digit user code to be deleted. Three beeps will be heard.
4. To delete further user codes repeat from step 2. To exit the programming mode press the key.
‘Delete All’
Warning only use in extreme circumstances, all settings will be lost.
1. Enter programming mode.
2. Press the key once, the unit bleeps twice, LED ashes.
Press the key a further 7 times. The unit will bleep 5 times & the LED will extinguish. All the user
codes are now deleted and the lock/relay time setting is changed to 1 second. The master code
is not aected.
Setting Lock/Relay time
The lock/relay will operate for a preset amount of time, factory setting is 5 seconds.
1. Enter programming mode.
2. Press 00 (this selects special user reference 00)
3. Enter the required lock/relay operation time 01-99 seconds
4. Press to exit programming mode.
#
#
#