CDVI CD97-4ID User manual

USER MANUAL
• Please read this manual carefully to ensure safe and correct operation.
• Keep this manual well for future reference.
RF CARD
RF CARD
2 WIRE SYSTEM
CDV97 Series
Fisheye Camera Door Station With Proximity Access Control
CD97-4ID CDV17-97A
CDV-ENG-97-V1 / 201608

CONTENTS
PARTS AND FUNCTIONS..................................................................................... 3
Part Names............................................................................................................. 3
Mounting................................................................................................................. 4
BASIC FUNCTIONS .............................................................................................. 6
Unlock Operations.................................................................................................. 6
Fisheye Camera ..................................................................................................... 6
External Motion Detection ...................................................................................... 6
SETUP INSTRUCTIONS........................................................................................ 7
Functions Setting Up .............................................................................................. 7
Setting Door Station Address ................................................................................. 8
Setting Door Station Calling Mode ......................................................................... 8
Setting Camera Resolution.................................................................................... 10
Setting Unlock Mode ............................................................................................. 10
Setting Unlock Time............................................................................................... 11
Setting Nameplate Illumination Mode.................................................................... 11
Setting Night View LED Illumination Mode............................................................ 12
Setting Ring-back Tone ......................................................................................... 12
Setting Image Display Mode.................................................................................. 13
Registering ID Card............................................................................................... 14
WIRING ................................................................................................................. 17
Connecting Electric Lock....................................................................................... 17
Connecting Basic One-to-one ............................................................................... 18
Connecting Multi Door Stations............................................................................. 18
Connecting Multi Monitors..................................................................................... 19
APPENDIX ............................................................................................................ 21
Precautions............................................................................................................ 21
Specication .......................................................................................................... 21
Cables and Requirments....................................................................................... 22

-3-
Part Names
PARTS AND FUNCTIONS
[11]
[10]
[9]
[1]
[3]
[4]
[8]
[7]
[6]
[5]
[12]
[13]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Front panel
[7] Speaker
[8] Night view LED
[9] Camera lens
[10] Rain cover
[11] Mounting hook
[12] Connection port
[13] Screw hole
[14] Mounting box

-4-
PARTS AND FUNCTIONS
Mounting
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
≥3mm
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Surface mounted
The installation height is suggested to 145~160cm.
* The camera angle view of surface mount model may be less than 1700.
Rain cover
Main Unit
12 3 4 5
The distance between
the top of main unit
and rain cover should
be not less than 3mm.
Main unit
Rain cover
1. Drill holes in the wall to match the size of wall plugs,then attach the rain cover and main
unit to the wall, the distance between the top of main unit and rain cover should be not less than
3mm.
2. Connect the cable correctly to the Bus terminals.
3. Install the name plate.
4. Attach the front panel to the main unit.
5. Use the Torx key (provided) to t the front panel.

-5-
PARTS AND FUNCTIONS
Terminal description
Lock Control Jumper: To select the lock type.
Main Connect Port: To connect the bus line and the electronic locks.
• L1,L2: Connect to the bus line, no polarity.
1 2 3
Lock Control Jumper
PIR Motion Detector
Connect Port
+12V
GND
PIR
L1 L2
PL
S+ S-
Main Connect Port
Motion Detector Connection Port: To connect external PIR motion detector.
• PL: External lock power input, connect to the PSU positive (lock control jumper removed).
• S+: Lock positive(+) output.
• S-: Lock negative(-) output, connect to the negative (-) connection of the lock (only when
using the door station to power the lock. When using an external PSU S- will not be
connected).

-6-
BASIC FUNCTIONS
Fisheye Camera
External Motion Detection
The door station is equipped with a terminal to
connect external motion detector.
Standard
door station angle
1700door camera angle
(Wide angle view shown)
12V
Motion
detector
GND
PIR
* Please contact with supplier for more details about
detector connection.
Unlock Operation
Unlocking by Card/Tag
When aregistered user card/tag is presented to the ID card window, the UNLOCK
indicator lights up, a single beep will be heard and the lock relay will activate.
• If an unauthorised user card/tag is presented,three beeps will be heard and the lock relay will NOT
activate.
Please note that this function requires a
monitor with sh-eye function to support.
The angle of view is 1700,visitors within this
angle can be seen clearly the image can then
be zoomed to see individuals up close CDV97-4ID
If an external motion detector is connected
to the door station the following functions will
be active:
If someone is detected at the door or passing
by, the door station can be set to activate
the unlock function or turn on a light.

-7-
SETUP INSTRUCTIONS
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
RF CARD
Order Setting items Setting range Default value
1 Setting door station address 0~3 0
2Setting door station
calling mode Standard/Group calling mode Standard calling mode
3 Setting camera resolution High/Low High
6Setting the nameplate
illumination mode On/Off/Auto On
7Setting night view LED
Zoom mode
Full screen mode
Alternate switching mode
This section explains the settings of each
function, please refer to the table below:
Each operation is indicated by the LED
indicator and the buzzer on the unit,
5 Setting the unlock time 01 to 99 seconds 1 seconds
4 Setting the unlock mode 0= Opened/1 = Closed 0 = Opened
On/Off/Auto Auto
illumination mode
Alternate switching mode
9 Setting image display mode
Ring Once
Ring Continuous
No ring-back tone
Function Programming
To carry out programming of the function
required, the metal front panel must be
removed. Please refer to Fig 1.

-8-
Setting Door Station Address
Setting Door Station Calling Mode
UNLOCK Indicator:OFF
TALK Indicator:OFF Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
the first door station.
Press KEY_2 button to set
the second door station.
Press KEY_3 button to set
the third door station.
Press KEY_4 button to set
the fourth door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep,Beep
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
PROGRAMMING INSTRUCTIONS
A total of 4 addresses can be congured. Addresses can be modied either before or
after installation. 0 is default, to change the setting, please follow the steps:
• If still in programming mode, addresses can still be changed by pressing KEY1~4 freely.
There are two call modes for the door station, Standard calling mode and Group calling
mode. Please note that the door station is set to Standard calling mode by default.
• The LED_NAME indicator will always flash while in programming mode.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To exit programming mode,press KEY_SET button four times to exit manually.

-9-
SETUP INSTRUCTIONS
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep+
Press KEY_1 button to
activate Standard calling
mode for door station.
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep, Beep
Press KEY_1 button again
to activate Group calling
mode for door station.
Press KEY_1
A
B
C
A
B
C
D
RF CARDRF CARD
A A
B
RF CARDRF CARD
2.Group calling mode
Each call button will respond to different addresses depending upon the calling mode set. Refer
to the following for more information.
1.Standard calling mode (Address range 01-04
by default)
Call button A: calls the monitor with address 01 by default.
Call button B: callsthe monitor with address 02 by default.
Call button C: callsthe monitor with address 03 by default.
Call button D: callsthe monitor with address 04 by default.
Call button A: Callsall monitors in group address
from 00~15.(at least one monitor must be set to 00)
Call button B,C,D: Callsall monitors in group address
from 16~31. (at least one monitor must be set to 16)
* For more details about monitor code(address) settings, please refer to corresponding user manual .
To change this setting, please follow the steps below:
• If still in programming mode, the calling mode can be changed by pressing KEY1 cyclically.
• The LED_NAME indicator will always flash while in programming mode.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To exit programming mode, press KEY_SET button four times to exit manually.

-10-
Setting Camera Resolution
Setting Unlock Mode
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep+
Press KEY_2 button to set the
camera to High resolution.
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep, Beep
Press KEY_2 button again
to set the camera to Low
resolution.
Press KEY_2
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set
the unlock mode to
Normally opened.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button again
to set the unlock mode to
Normally closed.
Press KEY_1
SETUP INSTRUCTIONS
The resolution of the camera can be changed at any time between high or low resolution.
High resolution is the default setting, to change the setting, please follow the steps below:
• If still in programming mode, the calling mode can be changed by pressing KEY2 cyclically.
• The LED_NAME indicator will always flash while in programming mode.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To exit programming mode, press KEY_SET button four times to exit manually.
There are 2 unlock modes, Normally open and Normally Closed.
Normally Open is default, to change the setting, please follow the steps below:
• If still in programming mode, the calling mode can be changed by pressing KEY1 cyclically.
• The LED_NAME indicator will always flash while in programming mode.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To exit programming mode, press KEY_SET button four times to exit manually.

-11-
Setting Nameplate Illumination Mode
Setting Unlock Time
SETUP INSTRUCTIONS
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep,Beep......
Press and hold on KEY_2
button. The time you holding
on is the new unlock time.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_3 button to set
the nameplate illumination
mode to Normally on.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_3 button again
to set the nameplate illumina-
tion mode to Normally off.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_3 button again
and again to set the nameplate
illumination mode to Auto.
Press KEY_3
By default, the unlock time is 1 second, the time setting range is 1~99 seconds.
To change the unlock time follow the steps below:
There are 3 illumination modes for the nameplate indicator, Normally on,Normally off and
Auto. Normally on is default, to change the setting, please follow the steps below:
• When entering the unlock time setting, the buzzer will beep once every second.
• The LED_NAME indicator will always flash while in programming mode.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To exit programming mode, press KEY_SET button four times to exit manually.
• If still in programming mode, the calling mode can be changed by pressing KEY3 cyclically.
• The LED_NAME indicator will always flash while in programming mode.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To exit programming mode, press KEY_SET button four times to exit manually.

-12-
Setting Ring-back Tone
Setting Night View LED Illumination Mode
SETUP INSTRUCTIONS
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_4 button to set
the night view LED mode
to Normally on.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_4 button again
to set the night view LED
mode to Normally off.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_4 button again
and again to set the night
view LED mode to Auto.
Press KEY_4
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep+
Press KEY_1 button to set
the ring-back call tone ringing
one time.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep, Beep
Press KEY_1 button again
to set the ring-back call tone
ringing continuously.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep, Beep,Beep
Press KEY_1 button again
and again to close ring-back
call tone.
Press KEY_1
There are 3 working modes for the night view LED, Normally on,Normally off and Auto. Auto
is the default setting, to change this setting, please follow the steps below:
• If still in programming mode, the calling mode can be changed by pressing KEY4 cyclically.
• The LED_NAME indicator will always flash while in programming mode.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To exit programming mode, press KEY_SET button four times to exit manually.
If the ring-back tone is set to either Once or Continuously, pressing the call button to call an
internal monitor will result in a ring-back call tone being heard at door station.
There are 3 ring-back call tones, Ring Once,Ringing Continuously and No ring-back tone.
Ring once is the default setting, to change the setting, please follow the steps below:
• While in programming mode, ring-tone callback mode can be changed by pressing KEY1 cyclically. •
The LED_NAME indicator will always flash while in programming mode.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To exit programming mode, press KEY_SET button four times to exit manually.

-13-
Setting Image Display Mode
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep+
Press KEY_2 button to set
the image display mode
to Cycle switching.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep, Beep
Press KEY_2 button again
to set the image display
mode to Zoom mode.
UNLOCK Indicator:ON
TALK Indicator:ON
Press KEY_2
Buzzer Beep, Beep,Beep
Press KEY_2 button again
and again to set the image
display mode to Full screen.
During setting mode, press KEY-2 to switch
Cycle switching mode, Zoom mode and Full screen mode in cycle.
SETUP INSTRUCTIONS
Full screen mode: when amonitor is being called, the image displayed will be Full screen
only.
Alternate switching mode is the default setting, to change the setting, please follow the steps below:
Alternate switching mode: when amonitor is called, the displayed image will switch between
Full screen and Zoom every 5 seconds.
Zoom mode: when amonitor is called, the displayed image will show full screen for 5
seconds, then switch to Zoom image.
When answering acall
When the door station calls a monitor, the camera image will be displayed on screen, there are
3modes for the displayed image, Alternate switching mode,Zoom mode and Full screen
mode.
PLEASE NOTE: The following settings are only applicable for monitors that do not
support manual screen operation for pan-tilt, i.e. CDV47M, CDV43 and CDV24
When the monitor is being called:
When answering acall, an image switching reminder can be activated or deactivated.
If set to activated, the image switching reminder will be dependant on the image display mode set.
Alternate switching mode: When answering the call, the reminder does not operate.
Zoom mode: When answering the call, the image will be displayed on full screen for 5 sec-
onds then switching to the Zoom image as a reminder to enter talking status.
• While in programming mode the image display setting can be changed by pressing KEY2 cyclically.
• The LED_NAME indicator will always flash while in programming mode.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To exit programming mode, press KEY_SET button four times to exit manually.

-14-
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep+
Press KEY_3 button to
activate image switching
when answering the call.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep, Beep
Press KEY_3 button again
to forbid image switching
when answering the call.
Press KEY_3
SETUP INSTRUCTIONS
Registering ID Card/Tags
• Up to 320 user cards can be registered to the door station.
• Easy management with LED status and sound hints.
• There are two master tags, one MASTER CARD ADD tag
and one MASTER CARD DELETE tag. When registering new
master cards, the old master cards are overwritten automatically.
• Card reading distance is less than 3cm.
• The master cards are necessary adding or deleting user cards.
Important: Please keep safe for future use.
• Proximity card frequency - 125kHz.
Full screen mode: When answering the call, the image will be displayed on Zoom mode for 5
seconds then switching to Full screen as a reminder to enter talking status.
'Image Switching' Off Mode: the image switching reminder will not function in any image
display mode. Activated is default, to change the setting, please follow the steps below:
By default, there are two master cards marked MASTER CARD ADD and MASTER CARD
DELETE,new master cardscan be authorised by users at any time. This means any two user
cards can be authorised as master cards. When registered new master cards, the old master
cards will be ioverwritten automatically.
Authorising master cards:
• While in programming mode the image display setting can be changed by pressing KEY3 cyclically.
• The LED_NAME indicator will always flash while in programming mode.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To exit programming mode, press KEY_SET button four times to exit manually.

-15-
SETUP INSTRUCTIONS
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep+, Beep
Show the master card of
MASTER CARD ADD to ID
card window in standby.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep+, Beep
Show the master card of
MASTER CARD DELETE
to ID card window.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+
Show the master card of
MASTER CARD DELETE
again to switch as a door
station access control.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+,Beep
Show the master card of
MASTER CARD DELETE
again to switch to DT-ACC
controlled.
UNLOCK Indicator:Blink two times
TALK Indicator:OFF
Buzzer Beep,Beep
Show the first card to ID
card window, set the card
of MASTER CARD ADD.
UNLOCK Indicator:Blink three times
TALK Indicator:OFF
Buzzer Beep,Beep,Beep
Show the second card to ID
card window, set the card of
MASTER CARD DELETE.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+, Beep
UNLOCK Indicator:Blink one time
TALK Indicator:OFF
Buzzer Beep+
Press KEY_2 button.
After powering on,within 10s,
press and hold on KEY_SET
button for 3s.
Access Control Outputs:
The access control output can be set to either the door station (local relay) or a CDV-ACC
to allow user and access level control from an online access control system such as Atrium.
• The LED_NAME indicator will constantly flash until the master card authorisation mode has been exited.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• The CDV97 will exit the setting mode automatically after presentation of the Master/Delete cards/Tags,the
UNLOCK&TALK indicator will turn off.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• If current access is controlled by door station, performing the above will 'toggle' to CDV-ACC,
performing once again will 'toggle' back to the door station.

-16-
Adding User Cards:
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:Blink one time
Buzzer Beep+
Show user cards to be
added in sequence.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep, Beep+
SETUP INSTRUCTIONS
Deleting User Cards:
Initializing Access (delete all user cards):
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
UNLOCK Indicator:Blink one time
TALK Indicator:OFF
Buzzer Beep+
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep, Beep+
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep+, Beep
UNLOCK Indicator:Blink for some time
TALK Indicator:Blink for some time
Buzzer Beep
Show the MASTER CARD
ADD to ID card window in
standby.
Show the MASTER CARD
ADD again to exit.
Show the MASTER CARD
DELETE to ID card window
in standby.
Show the MASTER CARD
ADD to ID card window.
Show the MASTER CARD
ADD again, format is
activated.
Show the MASTER CARD
DELETE to ID card window
in standby.
Show user cards to be
deleted in sequence.
Show the f MASTER
CARD DELETE again to
exit.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To add a user card, access control must be set to by station, see page 15.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To add a user card, access control must be set to door station, see page 15.
• If there is no operation within 10 seconds, the door station will exit programming mode automatically.
• To add user card, access control must be set to door station.
• During step 3, the UNLOCK & TALK indicator will flash constantly until formatting has nished.
• When formatting is nished, UNLOCK & TALK indicator will turn off followed by a “ Beep+ ” , exit of setting
mode will be completed automatically.

-17-
Connecting Electric Lock
Door Lock Controlled with Internal Power
Door Lock Controlled with Dry Contact
EB
*
LOCK
Jumper position on 2&3
1 2 3
L1 L2 PL S+ S-
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER
SUPPLY
WIRING
1.A fail secure (power on to unlock) should
be used.
2.The door lock output is limited to 12V at a
maximum of 250mA.
3.Connect the jumper across on position 2
and 3 before connecting the lock.
4.NOTE: The door lock control is not
timed from Exit Button(EB).
5.The Unlock Mode must be set to 0 ( default).
1. An external power supply must be used
in accordance to the lock requirements.
2.The internal relay contact is restricted
to 230Vac at 1A or 24Vdc at 1A.
3.The jumper must be removed before
connecting the lock etc.
4.Set the Unlock Mode according to
the lock type.
•Power-on-to-unlock, fail secure:
Unlock Mode=0 (default)
•Power-off-to-unlock, fail safe:
Unlock Mode=1
* CDV-RLC relay actuator is required for 2nd lock connection.

-18-
WIRING
Connecting Basic One-to-one
Connecting Multi Door Stations
BUS(IM) BUS(DS)
-
+
L1 L2 PL S+ S-
ID=0
Code=1, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
RF CARD
PC6A
AC~
100~240VAC
100~240VAC
DBC4A1
A B C D
OFF
ON
Impedance
switch
BUS(IM) BUS(DS)
PC6A
AC~
ID=0
1st door station
ID=1
2nd door station
ID=2
3rd door station
ID=3
4th door station
L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S-
To monitors
RF CARD RF CARD RF CARD RF CARD
•A maximum of 4 door stations can be connected to the system.
• Please ensure to set the correct address for each door station, please refer to Page 8 for
more details regarding setting the addresses of door stations.
• The door station is set to Standard mode in the example above. Refer to Page 9 for details.
• The door station is compatible with all monitors within the CDVI 2Easy range.

-19-
Basic IN-OUT Wiring in Standard Mode
Connecting Multi Monitors
WIRING
ID=0
Code=1, DIP6=off
Optional functional module
SCU camera module(max.4)
GSM module(mobile phone transfer)
TPS module(PBX transfer)
QSW image quad splitter module
(Master)
Code=1, DIP6=off
(Slave 2)
Code=1, DIP6=on
(Slave 3)
BUS(IM) BUS(DS)
PC6A
AC~
100~240VAC
Code=1, DIP6=off
(Slave 1)
RF CARD
SCU GSM TPS QSW
• Please set door station to group calling
mode if there are more than 4 monitors
on the system (Refer to Page 9)
• A Distributor (CDV-DBC4A) is not
required for a full audio system, daisy
chain connection is the recommended.
wiring format.
• The last monitor connected in this
format, should set to ON.
• The door station is compatible with all
monitors within the CDVI 2Easy range.

-20-
WIRING
DBC4A1
A B C D
RLC DBC4A1
OFF ON
Impedance
switch
BUS(IM) BUS(DS)
Code=1,DIP6=on Code=2,DIP6=on
Code=3,DIP6=on Code=4,DIP6=on
ID=0
RF CARD
PC6A
AC~
100~240VAC
Optional functional module
BDU
Star Topology Wiring With DBC4A1 in Standard Mode
BDU Bus amplifier module
RLC Relay/Lock module
DBC4A1 Branch distributor
• The door station is compatible with all monitors within the CDVI 2Easy range.
• The system can be extended by up to a maximum of 3slave monitors for each
monitor.(Connection via a CDV-DBC4A branch distributor is recommended)
This manual suits for next models
1
Table of contents
Other CDVI Intercom System manuals

CDVI
CDVI CDV-17HFA User manual

CDVI
CDVI CDV4796KP-DX User manual

CDVI
CDVI 2Easy CDV4796KP-DX User manual

CDVI
CDVI DMR18S User manual

CDVI
CDVI CDV97-8ID Series User manual

CDVI
CDVI CDV-DDP-F User manual

CDVI
CDVI CDV-471IP User manual

CDVI
CDVI 2EASY CDV-T5 User manual

CDVI
CDVI CDV91F User manual

CDVI
CDVI 2EASY CDV-91S User manual