EQ Series User Guide Installation Instructions
(continued)
2
Care and Maintenance
Periodic inspection and yearly maintenance by a licensed contractor is required for all thermostatic mixing elements. Corrosive water conditions and/or unauthorized adjustments or repair could
render the thermostatic valve ineffective for service intended. Regular checking and cleaning of the valve’s internal components and check stops helps assure maximum life and proper product
function.Frequencyofcleaningandinspectiondependsonlocalwaterconditions.AllChicagoFaucetsttingsaredesignedandengineeredtomeetorexceedindustryperformancestandards.
Care should be taken when cleaning this product. Do not use abrasive cleaners, chemicals, or solvents as they can result in surface damage. Use mild soap with warm water for cleaning and
protectingthesurfaceofChicagoFaucetsttings.
For additional technical assistance, call 800/TEC-TRUE (800-832-8783) or visit our website at chicagofaucets.com.
CHICAGO FAUCETS LIMITED WARRANTY
TO WHOM DOES THIS WARRANTY APPLY? — The Company extends the following limited warranty to the original user only.
WHAT DOES THIS WARRANTY COVER AND HOW LONG DOES IT LAST?
This warranty covers the following Commercial Products:
LIFETIME FAUCET WARRANTY—The“Faucet,”denedasanymetalcast,forged,stampedorformedportionoftheProduct,notincludingelectronicormovingpartsorother
products separately covered by this Limited Warranty or water restricting components or other components, is warranted against material manufacturing defects for the life of the Product.
FIVE YEAR FAUCET WARRANTY—CertainProductsandportionsoftheProductarewarrantedagainstmaterialmanufacturingdefectsforaperiodofve(5)yearsfromthedateofProductpurchase.Productswarrantedagainstmaterial
manufacturingdefectsforaperiodofve(5)yearsfromthedateofProductpurchasearereferredtobytheproductnumbers42X,43X,15XXandE-Tronic®-4X,5X,6X,7X,8Xand9X.AllzincdiecastportionsofProductarewarrantedagainst
materialmanufacturingdefectsforaperiodofve(5)yearsfromthedateofProductpurchase.
THREE YEAR ELECTRONICS WARRANTY — Electronic components, including the solenoid, are warranted for three (3) years from the date of installation.
FIVE YEAR CARTRIDGE WARRANTY—The“Cartridge”,denedasthemetalportionofanyProducttypicallyreferredtobytheproductnumberscontaining1-099,1-100,377X,
217Xand274X,excludinganyrubberorplasticcomponents,iswarrantedagainstmaterialmanufacturingdefectsforaperiodofve(5)yearsfromthedateofProductpurchase.
AllCartridgesincludedintheCompany’sSingleControlorShowerProductsalsoarewarrantedagainstmaterialmanufacturingdefectsforaperiodofve(5)yearsfromthedateofProductpurchase.
ONE YEAR FINISH WARRANTY – COMMERCIAL—ForProductsusedincommercialapplications,thenishoftheProductiswarrantedagainstmaterialmanufacturingdefectsforaperiod
of one (1) year from the date of Product purchase.
OTHER WARRANTIES — All other Products not covered above are warranted against material manufacturing defects for a period of one (1) year from the date of Product purchase.
Other restrictions and limitations apply. For complete warranty details, call Chicago Faucets Customer Service at 847-803-5000 or visit chicagofaucets.com.
© 2020 Chicago Faucet Company 957.109.00.0 06/20
The Chicago Faucet Company
2100 South Clearwater Drive
Des Plaines, IL 60018
Phone: 847/803-5000
Fax: 847/803-5454
Technical: 800/832-8783
www.chicagofaucets.com
User Adjustable Temperature Control
WARNING!
Delivery of water to fixtures intended for hand washing is recommended to be controlled by valves listed to ASSE 1070. This fitting is NOT factory preset and can be adjusted to deliver water at temperatures exceeding 110°F (43°C).
Further, mechanical mixing valves DO NOT provide automatic control of water temperature. Due to effects of various water conditions, periodic verification of outlet water temperature is required.
3. Reinstall the control box
cover and secure it with
the #2 Phillips screw.
1. Thread “T” connector
into yellow handle.
Slide the connecting
rod through slot in
handle and pull up
until it catches.
NOTE:Besurenottokinkcable.Limitcableloopingwherepossible.
2. Slide black riveted
attachment into the
groove of the control
box and push back
into large opening.
Completing Installation: Testing and Adjustment
1. Once wiring is
complete, the red
sensor light at the
outlet will glow for 5
seconds. After the light
switches off, place
your hands in front of
the faucet to activate.
2. Adjusting the Water Temperature
a. The yellow handle in the control box is used to adjust
water temperature. Turn clockwise to decrease or
counter-clockwise to increase temperature.
b. Water temperature must be checked at the point of
use. Temperature should not exceed 110°F (43°C).
Temperatures in excess 110°F (43°C) are dangerous
and may cause scalding, severe injury or death!
3. Slide locking clip into
place.
Remove screw
for box access
LTPS End of Life Directives (Recycling) In an effort to produce environmentally conscious products, the LTPS
contains materials that are required to be recycled by specialized companies. Please ensure you dispose of your
LTPS according to local regulations. Follow applicable laws and regulations for transport, shipping, and disposal of
batteries. For details on, and locations for recycling lithium based batteries, please contact a government recycling
agency, your waste-disposal service, or visit reputable on-line recycling sources such as www.call2recycle.org.
The faucet is leaking:
Fromoutlet–tightenorreplaceoutletinsertusingincludedkey.Fromsupplystops–installorreplacelterscreengaskets.
No water ow or ow is limited:
Makesuresupplyhosesareconnectedandstopsarefullyopen.Cleanorreplacelterscreengasketsoroutletinsert.Checkall
electronic connections.
Water ow does not stop:
Ifwaterowscontinuouslybutstopswhenhandentersdetectionzone,reversesolenoidelectricalconnections.
Faucet does not properly detect user:
To recalibrate, remove and reapply power or run faucet to maximum run time. Recalibration is complete when red light disappears.
QUICK TROUBLESHOOTING
Make sure detection zone and sensor are clear of debris, the power is on, and solid red light appears for 5 seconds after power-up. If these steps above do not solve the problem, visit chicagofaucets.com or contact customer service at 800/832-8783.
1
23
4
Connect Power: Self Sustaining Power System (SSPS)
i. Insert SSPS power supply
into control box upper
compartment. Attach
connectors, gray to gray,
black to black. Snap the
completed connections, into
the wiring harness as shown.
ii. Connect blue connector
on SSPS to blue
connector on the turbine
and tuck them into the
cavity as shown.
Connect Power: LTPS (DC)
1. Insert LTPS into control box
upper compartment, aligning
slots with compartment ribs.
Attach wiring connectors –
green to green, gray to gray.
2. Connect wiring connectors, gray to gray,
black to black. Snap into the wiring harness
Tuck the completed green connection into the
space as shown.
FOR EQ CONNECT UNITS
The wiring connectors are located on the
inside of the control box cover.
EQ Connect Devices - App Quick Start Guide
Download the EQ Connect app to your smartphone.
Search “eqconnect” on Google Play or on the App Store.
East, Floor 2, Sink 1
Open the app and your
bluetooth enabled phone
will scan for available
faucets. You can rename
faucets for easier
identification.
In the settings section,
adjust faucet and program
a hygiene-flush schedule.
The device section
provides information
on faucet usage and
downloadable logs.
The app allows you to
establish presets for faster
adjustment to multiple
faucets.