2. Fill out the exact model and OS of your server, then click Locate Software.
The Software/drivers page for this particular model appears.
3. Click Utilities.
4. Download the Diagnostics Utility and System Configuration Utility from this page.
Note: The blue LED which is located at the front and rear of an HP MCS 78XX server is called
the Unit Identification light (UID). The UID is a feature of all DL servers that allows the user to
distinguish which server they are working on in the rack. The UID can be lit from the CIM
console, as well as at the server by pressing either the front or rear UID button. Once lit, the LED
is blue in order to help the user identify the unit.
The Recommended Action column lists the steps necessary to correct the problem. After completion of
each step, run the Diagnostics program to verify whether the error condition is corrected. If the error
code reappears, perform the next step, then run the Diagnostics program again. Follow this procedure
until Diagnostics no longer detects an error condition.
Error Code Audible
Beeps
Probable
Source of
Problem
Recommended
Action
A Critical Error occurred
prior to this power-up. None
A
catastrophic
system error,
which cause
the server to
crash, has
been logged.
Run
Diagnostics.
Replace failed
assembly as
indicated.
Unsupported Processor Detected
System Halted 1 long,
1 short
Processor not
supported by
current
system ROM.
Check
documentation
for supported
processors, and
if supported,
remove the
processor and
update the
system to latest
ROM.
FATAL ROM ERROR: The
System ROM is not
properly programmed.
1 long,
1 short
ROM
programmed
in factory
incorrectly.
Replace the
physical ROM
part.
101 - ROM Error 1 long,
1 short System ROM
checksum.
Run
diagnostics.
Replace failed
assembly as
indicated.
Pa
e 3 of 13Cisco - Cisco MCS-78XX Boot Error Codes
10/2/2008htt
://kbase.cisco.com/
aws/servlet/ViewFile/12138/mcs