Quick Reference
Cisco ONS 15454 SONET and SDH TL1 Command Quick
Reference Guide, Release 4.7
This guide lists TL1 commands and autonomous messages by category. It includes basic
descriptions and input and output formats supported by Cisco ONS 15454 and
Cisco ONS 15454 SDH, Release 4.7.
TL1 commands conform to the following syntax:
a:b:c:d:e: ...z;
where:
“a” is the Command Code
“b” is the Target Identifier (TID)
“c” is the Access Identifier (AID) or the User Identifier (UID)
“d” is the Correlation Tag (CTAG)
“e: ...z;” are other positions required for various commands
The TID, AID, and CTAG parameters route and control the TL1 command.
The remaining parameters provide additional information required to complete
the action requested by the command.
2
1 DWDM
Ta b l e 1 DW D M
COPY-RFILE:[<TID>]:[<SRC>]:<CTAG>::TYPE=<XFERTYPE>,[SRC=<SRC1>,]
[DEST=<DEST>,][OVWRT=<OVWRT>,][FTTD=<FTTD>];
Downloads a new software package or file from the location specified by the FTP URL.
DLT-EQPT:[<TID>]:<AID>:<CTAG>[:::];
Deletes a card from the Network Element (NE).
DLT-LNK-<MOD2O>:[<TID>]:<FROM>,<TO>:<CTAG>;
Deletes an optical link between two optical connection points.
DLT-OSC:[<TID>]:<AID>:<CTAG>;
Deletes the Optical Service Channel (OSC) group of the NE.
DLT-<PAYLOAD>:[<TID>]:<AID>:<CTAG>;
Deletes a port connection from a client port to a supported payload type.
DLT-WLEN:[<TID>]:<AID>:<CTAG>:::[CMDMDE=<CMDMDE>][:];
Deletes the provisioned wavelength (WLEN).
ED-10GIGE:[<TID>]:<AID>:<CTAG>:::[NAME=<PORTNAME>,][MACADDR=<MACADDR>]:
[<PST>],[<SST>];
Edits the 10 GBit/sec parameters for the 10GIGE port.
ED-ALS:[<TID>]:<AID>:<CTAG>:::[ALSMODE=<ALSMODE>,][ALSRCINT=<ALSRCINT>,]
[ALSRCPW=<ALSRCPW>,][:];
Edits the Automatic Laser Shutdown (ALS) attributes of an OC-N facility and all facilities that
support the ALS feature.
ED-APC:[<TID>]::<AID>::<CTAG>:::[APC-ENABLE=<APCENABLE>][:];
Edits Amplification Power Control (APC) application attributes.
ED-ESCON:[<TID>]:<AID>:<CTAG>:::[ENCAP=<ENCAP>,][CMDMDE=<CMDMDE>][:]
[<PST>[,<SST>]];
Edits the attributes for an Enterprise System Connection (ESCON) interface.
ED-EQPT:[<TID>]:<AID>:<CTAG>:::[PEERID=<PEERID>,]
[REGENNAME=<REGENNAME>,][PWL=<PWL>,][CARDMODE=<CARD_MODE>];
Edits the attributes for a given equipment slot in the NE. If the card is in an equipment slot, this
command is allowed only on the working AID.
ED-FFP-OCH::[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>,][RVRTV=<RVRTV>,]
[RVTM=<RVTM>,][PSDIRN=<PSDIRN>][:];
Edits the provisioning for the default protection group on the DWDM port of a TXP_MR_2.5G or
TXPP_MR_2.5G card.
3
ED-GIGE:[<TID>]:<AID>:<CTAG>:::[ENCAP=<ENCAP>,][CMDMDE=<CMDMDE>[:]
[<PST>[<,<SST>]];
Edits the Gigabit Ethernet-specific parameters for the port.
ED-LNK-<MOD2O>:[<TID>]:<FROM>,<TO>:<CTAG>::::<PST>,[<SST>];
Edits an optical link.
ED-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>,]
[CMDMDE=<CMDMDE>]:<PST>,[<SST>];
Edits the operating parameters for a DWDM facility.
ED-OCH:[<TID>]:<AID>:<CTAG>:::[NAME=<PORTNAME>,][SFBER=<SFBER>,]
[SDBER=<SDBER>,][ALSMODE=<ALSMODE>,][ALSRCINT=<ALSRCINT>,]
[ALSRCPW=<ALSRCPW>,][COMM=<COMM>,][GCCRATE=<GCCRATE>,]
[OSDBER=<OSDBER>,][DWRAP=<DWRAP>,][FEC=<FEC>,]
[PAYLOAD-MAP=<PAYLOADMAP>,][RLASER=<RLASER>,][SOAK=<SOAK>]:[<PST>],
[<SST>];
Edits the operating parameters of an Optical Channel (OCH) facility.
ED-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[NAME=<PORTNAME>,][DCC=<DCC>,]
[GCC=<GCC>,][AREA=<AREA>,][SYNCMSG=<SYNCMSG>,][SENDDUS=<SENDDUS>,]
[PJMON=<PJMON>,][SFBER=<SFBER>,][SDBER=<SDBER>,][MODE=<MODE>,]
[MUX=<MUX>,][SOAK=<SOAK>,][OSPF=<OSPF>,][LDCC=<LDCC>,][NAME=<NAME>,]
[EXPTRC=<EXPTRC>,][TRC=<TRC>,][TRCMODE=<TRCMODE>,]
[TRCFORMAT=<TRCFORMAT>,][CMDMDE=<CMDMDE>]:<PST>,[<SST>];
Edits the attributes (service parameters) and state of an OC-N facility.
ED-OMS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>,][EXPBAND=<EXPBAND>,]
[VOAATTN=<VOAATTN>,][VOAPWR=<VOAPWR>,][CALOPWR=<CALOPWR>,]
[CHPOWER=<CHPOWER>]:[<PST>],[<SST>];
Edits the attributes (service parameters) and state of an Optical Multiplex Section (OMS) facility.
ED-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>,][NODEID=<NODEID>];
Edits the Optical Service Channel (OSC) group attributes.
ED-OTS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>,][VOAATTN=<VOAATTN>,]
[VOAPWR=<VOAPWR>,][OFFSET=<OFFSET>,][CALTILT=<CALTILT>,][OSRI=<OSRI>,]
[AMPLMODE=<AMPLMODE>,][CHPOWER=<CHPOWER>,][EXPGAIN=<EXPGAIN>,]
[NAME=<NAME>,][CMDMDE=<CMDMDE>]:[<PST>],[<SST>];
Edits the attributes (service parameters) and state of an OTS facility.
ED-SLV-WDMANS:[<TID>]:[<AID>]:<CTAG>:::[HIGHSLVEXP=<HIGHSLVEXP>,]
[LOWSLVEXP=<LOWSLVEXP>][:];
Provisions the expected span loss verification.
Table 1 DWDM (continued)
4
ED-TRC-OCH:[<TID>]:<SRC>:<CTAG>:::[EXPTRC=<EXPTRC>,][TRC=<TRC>,]
[TRCMODE=<TRCMODE>,][TRCLEVEL=<TRCLEVEL>,][TRCFORMAT=<TRCFORMAT>][:];
Edits trace-related optical channel facilities.
ED-WDMANS:[<TID>]:<AID>:<CTAG>:::[POWERIN=<POWERIN>,]
[POWEROUT=<POWEROUT>,][POWEREXP=<POWEREXP>,][NTWTYPE=<RINGTYPE>,][:];
Edits the optical node setup application attributes.
ED-WLEN:[<TID>]:<AID>:<CTAG>:::[SIZE=<SIZE>]:[<PST>],[<SST>];
Edits wavelength (WLEN) provisioning.
ENT-EQPT:[<TID>]:<AID>:<CTAG>::[<EQPTTYPE>]:[PEERID=<PEERID>,]
[REGENNAME=<REGENNAME>,][PWL=<PWL>,][CARDMODE=<CARD_MODE>];
Creates the card type and attributes for a given equipment slot in the NE. It also automatically enters
all facilities supported by the card, assigning default values to all port and path attributes.
ENT-LNK-<MOD2O>:[<TID>]:<FROM>,<TO>:<CTAG>::::<PST>,[<SST>];
Creates an optical link between two optical connection points.
ENT-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>,]NODEID=<NODEID>,]
[EAST=<EAST>,][WEST=<WEST>];
Creates the OSC (optical service channel) group of the NE.
ENT-<PAYLOAD>:[<TID>]:<AID>:<CTAG>;
Creates a port connection from a client port to a supported payload type.
ENT-WLEN:[<TID>]:<AID>:<CTAG>::[<WCT>]:[SIZE=<SIZE>]:[<PST>],[<SST>];
Allocates a wavelength.
INIT-REG-<MOD2>:[<TID>]:<AID>:<CTAG>::<MONTYPE>,,[<LOCN>],[<DIRN>],
[<TMPER>][,,];
Initializes the performance monitoring registers on an OMS card.
OPR-ALS:[<TID>]:<AID>:<CTAG>[:::::];
Restarts the laser of an OC-N facility and all facilities that support the ALS feature.
OPR-APC:[<TID>]::<CTAG>[::::];
Permits the Amplifier Power Control (APC) application inside the NE to force regulation of the
optical power to the entire DWDM ring.
OPR-LNK:[<TID>]::<CTAG>;
Permits the optical link application inside the NE to calculate all the automatic optical links between
end points that can be univocally identified by the NE.
OPR-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>[::];
Performs a protection switch on the trunk port of a TXPP_MR_2.5G card.
Table 1 DWDM (continued)
5
OPR-SLV-WDMANS:[<TID>]:<AID>:<CTAG>[::::];
Invokes the calculation of the expected span loss verification.
OPR-WDMANS:[<TID>]::<CTAG>;
Operates the Automatic Optical Node Setup (AONS) application inside the NE to force a recompute
of the value to be assigned to all variable optical attenuators (VOAs) representing the Optical Path
inside the node.
RLS-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>[::];
Performs a protection switch on the trunk port of a TXPP_MR_2.5G card.
RMV-<MOD2_IO>:[<TID>]:<AID>:<CTAG>::[<CMDMODE>],[<PST>],[<SST>];
Removes a facility from service.
RST-<MOD2_IO>:[<TID>]:<AID>:<CTAG>[::];
Provisions a facility in-service.
RTRV-10GIGE:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the 10 GBit/sec parameters for the 10GIGE port.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::[NAME=<PORTNAME>,][MACADDR=<MACADDR>,][LBCL=<LBCLCURR>,]
[OPT=<OPTCURR>,][OPR=<OPRCURR>]:<PST>,[<SST>]”
;
RTRV-ALM-ALL:[<TID>]::<CTAG>::[<NTFCNCDE>],[<CONDITION>],[<SRVEFF>][,,,];
Retrieves and sends the current status of all active alarm conditions.
Output format:
SID DATE TIME
M CTAG COMPLD
“[<AID>],[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>],[<AIDDET>]”
;
RTRV-ALM-EQPT:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],
[<SRVEFF>][,,,];
Retrieves and sends the current status of alarm conditions associated with the equipment units.
Output format:
SID DATE TIME
M CTAG COMPLD
“[<AID>],[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>]”
;
Table 1 DWDM (continued)
6
RTRV-ALM-<MOD2ALM>:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],
[<SRVEFF>][,,,];:
Instructs the NE to retrieve and send the current status of an alarm condition.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,
:[<DESC>]”
;
RTRV-ALMTH-<MOD2>:[<TID>]:<AID>:<CTAG>::<ALMTHR>[,,::];
Retrieves the alarm threshold values.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<MOD>:<CONDTYPE>,,,<THLEVEL>”
;
RTRV-ALS:[<TID>]:<AID>:<CTAG>[:::::];
Retrieves the ALS attributes of an OC-N facility and all facilities that support the ALS feature.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<AIDTYPE>::[ALSMODE=<ALSMODE,>][ALSRCINT=<ALSRCINT>,]
[ALSRCPW=<ALSRCPW>,][LSRSTAT=<LSRSTAT>]:”
;
RTRV-APC:[<TID>]::<AID>::<CTAG>[::::];
Retrieves the APC application attributes.
Output format:
SID DATE TIME
M CTAG COMPLD
“::[APCENABLE=<APCENABLE>,][APCSTATE=<APCSTATE>][:]”
;
Table 1 DWDM (continued)
7
RTRV-COND-ALL:[<TID>]::<CTAG>::[<TYPEREQ>][,,,];
Retrieves the current standing condition for all entities.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],[<OCRDAT>],
[<OCRTM>],,,[<DESC>]”
;
RTRV-COND-EQPT:[<TID>]:<AID>:<CTAG>::[<TYPEREQ>][,,,];
Retrieves the equipment conditions.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],[<OCRDAT>],
[<OCRTM>],,,[<DESC>]”
;
RTRV-COND-<MOD2ALM>:[<TID>]:<AID>:<CTAG>::[<TYPEREQ>][,,,];
Retrieves the current standing condition or/and state associated with an entity.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],[<OCRDAT>],
[<OCRTM>],,,[<DESC>]”
;
RTRV-ESCON:[<TID>]:<AID>:<CTAG>;
Retrieves the attributes for an ESCON interface.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::[NAME=<PORTNAME>,]ENCAP=<ENCAP>:<PST>,<SST>”
;
Table 1 DWDM (continued)
8
RTRV-EQPT:[<TID>]:<AID>:<CTAG>;
Retrieves card level attributes.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>:<EQPTTYPE>,<EQUIP>,[<ROLE>],[<STATUS>]:[PROTID=<PROTID>,]
[PRTYPE=<PRTYPE>,][RVRTV=<RVRTV>,][RVTM=<RVTM>,]
[CARDNAME=<CARDNAME>,][PEERID=<PEERID>,][REGENNAME=<REGENNAME>,]
[PWL=<PWL>,][CARDMODE=<CARD_MODE>:]<PST>],[<SST>]”
;
RTRV-FAC:[<TID>]:<SRC>:<CTAG>[::::];
Retrieves facility data (port data).
Output format:
SID DATE TIME
M CTAG COMPLD
"<SRC>::PAYLOAD=<PAYLOAD>:<PST_PSTQ>,[<SSTQ>]"
;
RTRV-FFP-OCH:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the protection group information for the TXPP_MR_2.5G trunk port.
Output format:
SID DATE TIME
M CTAG COMPLD
“<WORK>,<PROTECT>::[PROTTYPE=<PROTTYPE>,][PROTID=<PROTID>,]
[RVRTV=<RVRTV>,][RVTM=<RVTM>,][PSDIRN=<PSDIRN>]”
;
RTRV-GIGE:[<TID>]:<AID>:<CTAG>;
Retrieves the Gigabit Ethernet-specific parameters for the port.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::[ADMINSTATE=<ADMINSTATE>,][LINKSTATE=<LINKSTATE>,]
[MTU=<MTU>,][FLOWCTRL=<FLOWCTRL>,][OPTICS=<OPTICS>,]
[DUPLEX=<DUPLEX>,][SPEED=<SPEED>,][ENCAP=<ENCAP>]:<PST>[SST>]”
;
Table 1 DWDM (continued)
9
RTRV-INV:[<TID>]:<AID>:<CTAG>[::::];
Queries the NE and returns a listing of the equipment inventory. For each unit in the system, it
identifies the unit’s firmware numbers and the unit’s Common Language Equipment Identification
(CLEI) code.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<AIDTYPE>::[PN=<PN>],[HWREV=<HWREV>],[FWREV<FWREV>],
[SN=<SN>],[CLEI=<CLEI>],[TWL1=<TWL1>],[TWL2=<TWL2>],[TWL3=<TWL3>],
[TWL4=<TWL4>]””
;
RTRV-LNK:[<TID>]::<CTAG>;
Retrieves all the optical links created in the NE.
Output format:
SID DATE TIME
M CTAG COMPLD
“<FROM>,<TO>::[OLNKT=<OLNKT>,][CTYPE=<CTYPE>,][RDIRN=<RDIRN>,]
[BAND=<BAND>,][WLEN=<WLEN>]:<PST>,[<SST>]”
;
RTRV-LNK-<MOD2O>:[<TID>]:<AID>:<CTAG>:::[OLNKT=<OLNKT>,][CTYPE=<CTYPE>,]
[RDIRN=<RDIRN>];
Retrieves any optical link associated with the entered AIDs or AID range.
Output format:
SID DATE TIME
M CTAG COMPLD
“<FROM>,<TO>::[OLNKT=<OPTICALLINKTYPE>,][CTYPE=<CREATIONTYPE>,]
[RDIRN=<RDIRN>,][BAND=<BAND>,][WLEN=<WLEN>]:<PST>,[<SST>]”
;
RTRV-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the configuration parameters of a DWDM Client.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<AIDTYPE>::[NAME=<NAME>,][LBCL=<LBCL>,][OPT=<OPT>,][OPR=<OPR>]:
<PST_PSTQ>,[<SST>]”
;
Table 1 DWDM (continued)
10
RTRV-NE-APC:[<TID>]::<CTAG>;
Retrieves the APC application ports that are involved in node setup regulation.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<AIDTYPE>::[MODIFDAT=<MODIFDAT>,][MODIFTM=<MODIFTM>,]
[CHECKDAT=<CHECKDAT>,][CHECKTM=<CHECKTM>, [:]”
;
RTRV-NE-WDMANS:[<TID>]:[<AID>]:<CTAG>[::::];
Retrieves the optical node setup application ports involved in node setup regulation.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<AIDTYPE>::[REGULATED=<REGULATED,>][PARAM=<PARAM>][:]”
;
RTRV-OCH:[<TID>]:<AID>:<CTAG>;
Retrieves the attributes (service parameters) and state of an OCH facility.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>:,,,[<STATUS>]:[NAME=<PORTNAME>,][SFBER=<SFBER>,]
[SDBER=<SDBER>,][ALSMODE=<ALSMODE>,][ALSRCINT=<ALSRCINT>,]
[ALSRCPW=<ALSRCPW>,][COMM=<COMM>,][GCCRATE=<GCCRATE>,]
[DWRAP=<DWRAP>,][FEC=<FEC>,][PAYLOAD-MAP=<PAYLOADMAP>,]
[OFSBER=<OFSBER>][OSDBER=<OSDBER>][MACADDR=<MACADDR>,]
[SYNCMSG=<SYNCMSG>,][SENDDUS=<SENDDUS>,][LSRSTAT=<LSRSTAT>,]
[LBCL=<LBCL>,][OPT=<OPT>,][OPR=<OPR>][SOAK=<SOAK>]:,PST>,[<SST>]”
;
Table 1 DWDM (continued)
11
RTRV-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>[:::::]
Retrieves the attributes (service parameters) and state of an OC-N facility.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>:,,[<ROLE>],[<STATUS>]:[NAME=<PORTNAME>,][DCC=<DCC>,]
[GCC=<GCC>,][NAME=<NAME>,][CMDMDE=<CMDMDE>,][EXPTRC=<EXPTRC>,]
[INCTRC=<INCTRC>,][TRC=<TRC>,][TRCMODE=<TRCMODE>,]
[TRCFORMAT=<TRCFORMAT>,][AREA=<AREA>,][TMGREF=<TMGREF>,]
[SYNCMSG=<SYNCMSG>,][SENDDUS=<SENDDUS>,][PJMON=<PJMON>,]
[SFBER=<SFBER>,][SDBER=<SDBER>,][MODE=<MODE>,][WVLEN=<WVLEN>,]
[RINGID=<RINGID>,] [BLSRTYPE=<BLSRTYPE>,][MUX=<MUX>,]
[UNIC=<UNIC>,][CCID=<CCID>,][NBRIX=<NBRIX>,][SOAK=<SOAK>,]
[SOAKLEFT=<SOAKLEFT>,][SSMRCV=<SSMRCV>,][OSPF=<OSPF>,]
[LDCC=<LDCC>,][LBCK=<LBCL>,][OPT=<OPT>,][OPR=<OPR>:]<PST>,[<SST>]”
;
RTRV-OMS:[<TID>]:<AID>:<CTAG>;
Retrieves the attributes (service parameters) and state of an OMS facility.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::RDIRN=<RDIRN>,OPTYPE=<OPTICALPORTTYPE>,[OPWR=<POWER>,]
EXPBAND=<EXPBAND>,[ACTBAND=<ACTBAND>,][ILOSS=<ILOSS>,]
[VOAMODE=<VOAMODE>,][VOAATTN=<VOAATTN>,][VOAPWR=<VOAPWR>,]
[VOAREFATTN=<VOAREFATTN>,][VOAREFPWR=<VOAREFPWR>,]
[REFOPWR=<REFOPWR>,][CALOPWR=<CALOPWR>,][CHPOWER=<CHPOWER>]:<PST>,
[<SST>]”
;
RTRV-OPM:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the optical power monitoring parameters that are present at the OCH layer in a
reconfigurable optical add/drop multiplexing (ROADM) node.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::[POWEROUT=<POWEROUT>,][POWERADD=POWERADD>,]
[POWEREPT=<POWEREPT>][:]
;
Table 1 DWDM (continued)
12
RTRV-OSC:[<TID>]:<AID>:<CTAG>;
Retrieves the OSC information of the NE.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::[RINGID=<RINGID>,][NODEID=<NODEID>,][EAST=<EAST>,][WEST=<WEST>]”
;
RTRV-OTS:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the attributes (service parameters) and state of an OTS facility.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>:RDIRN=<RDIRN>,OPTYPE=<OPTICALPORTTYPE>,[OPWR=<POWER>,]
[ILOSS=<ILOSS>,][VOAMODE=<VOAMODE>,][VOAATTN=<VOAATTN>,]
[VOAPWR=<VOAPWR>,][VOAREFATTN=<VOAREFATTN>,]
[VOAREFPWR=<VOAREFPWR>,][OSRI=<OSRI>,][AMPLMODE=<AMPLMODE>,]
[CHPOWER=<CHPOWER>,][GAIN=<GAIN>,][EXPGAIN=<EXPGAIN>,]
[REFOPWR=<REFOPWR>,][OFFSET=<OFFSET>,][REFTILT=<REFTILT>,]
[CALTILT=<CALTILT>,][ASEOPWR=<ASEOPWR>,][DCULOSS=<DCULOSS>,]
[AWGST=<AWGST>,][HEATST=<HEATST>,][NAME=<NAME>]:<PST>,[<SST>]”
;
RTRV-PM-<MOD2>:[<TID>]:<AID>:<CTAG>::[<MONTYPE>],[<MONLEV>],[<LOCN>],
<DIRECTION>,[<TMPER>],[<DATE>],[<TIME>];
Retrieves the values of performance monitoring parameters for the specified card type.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:<MONTYPE>,<MONVAL>,[<VLDTY>],[<LOCN>],<DIRECTION>,
[<TMPER>],[<MONDAT>],[<MONTM>]”
;
Table 1 DWDM (continued)
13
RTRV-PMSCHED-<MOD2>:[<TID>]:<AID>:<CTAG>;
Retrieves the performance monitoring (PM) reporting schedule that was set for the NE by the
SCHED-PMREPT-OTS command.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:<REPTINVL>,<REPTDAT>,<REPTTM>,[<NUMINVL>],,
[<MONLEV>],<LOCN>,,[<TMPER>],[<TMOFST>],[<INHMODE>]”
;
RTRV-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>;
Retrieves the protection switch status of a TXPP_MR_2.5G card.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>:<SW>,<SWTYPE>”
;
RTRV-SLV-WDMANS:[<TID>]:[<AID>]:<CTAG>[::::];
Retrieves the options provisioned by the ED-SLV-WDMANS command.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::[HIGHSLVEXP=<HIGHSLVEXP>,][LOWSLVEXP=<LOWSLVEXP>,]
[SLVACT=<SLVACT>,][RESOLUTION=<RESOLUTION>][:]”
;
RTRV-TH-<MOD2>:[<TID>]:<AID>:<CTAG>::[<MONTYPE>],[<LOCN>],<TMPER>[::];
Retrieves the current threshold level of one or more monitored parameters.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:<MONTYPE>,[<LOCN>],,<THLEV>,[<TMPER>]”
;
Table 1 DWDM (continued)
14
RTRV-TRC-OCH:[<TID>]:<SRC>:<CTAG>::[<MSGTYPE>],[<TRCLEVEL>][::];
Retrieves the sent trace string, expected trace string, received trace string, trace mode, and trace level
for the SONET J0 Section Trail Trace Identifier (TTI) Path and Section monitoring levels of the
DWDM facility.
Output format:
SID DATE TIME
M CTAG COMPLD
“<CHANNEL>,<MOD>::[TRCLEVEL=<TRCLEVEL>,][EXPTRC=<EXPTRC>,][TRC=<TRC>,]
[INCTRC=<INCTRC>,][TRCMODE=<TRCMODE>,][TRCFORMAT=<TRCFORMAT>]”
;
RTRV-WDMANS:[<TID>]:<AID>:<CTAG>{::::};
Retrieves the automatic optical node setup application attributes.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::[POWER-IN=<POWERIN>,][POWEROUT=<POWEROUT>,]
[POWER-EXP=<POWEREXP>,][NTWTYPE=<RINGTYPE>,]
[OPTICALTYPE=<OPTICALTYPE>,][LASTRUNDAT=<LASTRUNDATE>,]
[LASTRUNTM=<LASTRUNTM>][:]”
;
RTRV-WLEN:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the wavelength provisioning information.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>:<WCT>:[SIZE=<SIZE>]:[<PST>],[<SST>]”
;
SCHED-PMREPT-<MOD2>:[<TID>]:<SRC>: <CTAG>::[<REPTINVL>],[<REPTSTATM>],
[<NUMREPT>],,[<MONLEV>],[<LOCN>],,[<TMPER>],[<TMOFST>];
Schedules/reschedules the NE to report the performance monitoring data for an OMS facility, using
an automatic REPT^PM message. It also allow the user to remove a previously created schedule.
SET-ALMTH-<MOD2>:[<TID>]:<AID>:<CTAG>::<CONDTYPE>,<THLEV>[,,,];
Sets the alarm thresholds on a facility/port/channel.
SET-TH-<MOD2>:[<TID>]:<AID>:<CTAG>::<MONTYPE>,<THLEV>,[<LOCN>],,[<TMPER>];
Sets the thresholds for PM and the alarm thresholds for a card facility.
Table 1 DWDM (continued)
15
Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
European Headquarters
Cisco Systems International BV
Haarlerbergpark
Haarlerbergweg 13-19
1101 CH Amsterdam
The Netherlands
www-europe.cisco.com
Tel: 31 0 20 357 1000
Fax: 31 0 20 357 1100
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
www.cisco.com
Tel: 408 526-7660
Fax: 408 527-0883
Asia Pacific Headquarters
Cisco Systems, Inc.
168 Robinson Road
#28-01 Capital Tower
Singapore 068912
www.cisco.com
Tel: +65 6317 7777
Fax: +65 6317 7799
Cisco Systems has more than 200 offices in the following countries. Addresses, phone numbers, and fax numbers are listed on the
Cisco Web site at www.cisco.com/go/offices
Argentina • Australia • Austria • Belgium • Brazil • Bulgaria • Canada • Chile • China PRC • Colombia • Costa Rica • Croatia • Cyprus • Czech Republic • Denmark
Dubai, UAE • Finland • France • Germany • Greece • Hong Kong SAR • Hungary • India • Indonesia • Ireland • Israel • Italy • Japan • Korea • Luxembourg
Malaysia • Mexico • The Netherlands • New Zealand • Norway • Peru • Philippines • Poland • Portugal • Puerto Rico • Romania • Russia • Saudi Arabia • Scotland
Singapore • Slovakia • Slovenia • South Africa • Spain • Sweden • Switzerland • Taiwan • Thailand • Turkey • Ukraine • United Kingdom • United States • Venezuela
Vietnam • Zimbabwe
Printed in the USA on recycled paper containing 10% postconsumer waste.
78-16555-01
DOC-7816555=
CCVP, the Cisco logo, and Welcome to the Human Network are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is a service mark of
Cisco Systems, Inc.; and Access Registrar, Aironet, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the Cisco Certified Internetwork Expet logo, Cisco IOS,
Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me Browsing,
FormShare, GigaDrive, HomeLink, Internet Quotient, IOS, iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace,
MGX, Networkers, Networking Academy, Network Registrar, PIX, ProConnect, ScriptShare, SMARTnet, StackWise, The Fastest Way to Increase Your Internet Quotient, and
TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship
between Cisco and any other company. (0711R)

This manual suits for next models

1

Other Cisco Server manuals

Cisco UCS C240 M5 Installation and maintenance instructions

Cisco

Cisco UCS C240 M5 Installation and maintenance instructions

Cisco UCS C240 M3 User manual

Cisco

Cisco UCS C240 M3 User manual

Cisco UCS C24 Installation and maintenance instructions

Cisco

Cisco UCS C24 Installation and maintenance instructions

Cisco MCS-7825-H1-IPC1 User manual

Cisco

Cisco MCS-7825-H1-IPC1 User manual

Cisco TelePresence MSE 8710 User manual

Cisco

Cisco TelePresence MSE 8710 User manual

Cisco TelePresence Video Communication Server... User manual

Cisco

Cisco TelePresence Video Communication Server... User manual

Cisco TelePresence MSE 8710 User manual

Cisco

Cisco TelePresence MSE 8710 User manual

Cisco UCS 5100 Quick start guide

Cisco

Cisco UCS 5100 Quick start guide

Cisco UCS B22 M3 Manual

Cisco

Cisco UCS B22 M3 Manual

Cisco CDE 220 Series Manual

Cisco

Cisco CDE 220 Series Manual

Cisco UCS C210 Installation and maintenance instructions

Cisco

Cisco UCS C210 Installation and maintenance instructions

Cisco UCS B22 M3 User manual

Cisco

Cisco UCS B22 M3 User manual

Cisco UCS X9508 Quick start guide

Cisco

Cisco UCS X9508 Quick start guide

Cisco IE-3000-8TC Instruction Manual

Cisco

Cisco IE-3000-8TC Instruction Manual

Cisco 3500 Series User manual

Cisco

Cisco 3500 Series User manual

Cisco UCS 6500 Series User manual

Cisco

Cisco UCS 6500 Series User manual

Cisco IP/TV 3400 Series User manual

Cisco

Cisco IP/TV 3400 Series User manual

Cisco Nexus 7000 Series User manual

Cisco

Cisco Nexus 7000 Series User manual

Cisco Firepower Management Centers User manual

Cisco

Cisco Firepower Management Centers User manual

Cisco UCS X210c M6 Manual

Cisco

Cisco UCS X210c M6 Manual

Cisco UCS B460 M4 User manual

Cisco

Cisco UCS B460 M4 User manual

Cisco UCS C260 Installation and maintenance instructions

Cisco

Cisco UCS C260 Installation and maintenance instructions

Cisco UCS C240 M4 Installation and maintenance instructions

Cisco

Cisco UCS C240 M4 Installation and maintenance instructions

Cisco Content Delivery Engine CDE100 Manual

Cisco

Cisco Content Delivery Engine CDE100 Manual

Popular Server manuals by other brands

IBM System x3620 M3 7376 Installation and user guide

IBM

IBM System x3620 M3 7376 Installation and user guide

TYAN Transport TA26 B2882 Service manual

TYAN

TYAN Transport TA26 B2882 Service manual

Synology RackStation RS2818RP+ Hardware installation guide

Synology

Synology RackStation RS2818RP+ Hardware installation guide

Intergraph InterServe 800 SL manual&nbsp;

Intergraph

Intergraph InterServe 800 SL manual&nbsp;

LG 24CK550N-3A owner's manual

LG

LG 24CK550N-3A owner's manual

HP ProLiant MicroServer Installation sheet

HP

HP ProLiant MicroServer Installation sheet

Inspur I48 installation guide

Inspur

Inspur I48 installation guide

NEC Express5800/B120g-h Maintenance Guide

NEC

NEC Express5800/B120g-h Maintenance Guide

Fujitsu SE310 operating manual

Fujitsu

Fujitsu SE310 operating manual

Gateway 8450R System manual

Gateway

Gateway 8450R System manual

AIC SB101-SP user manual

AIC

AIC SB101-SP user manual

IBM Power System POWER7 Series Common Service Procedures

IBM

IBM Power System POWER7 Series Common Service Procedures

IBM RS/6000 Enterprise Server M80 user guide

IBM

IBM RS/6000 Enterprise Server M80 user guide

Five9NS R2100RS installation manual

Five9NS

Five9NS R2100RS installation manual

DMP Electronics EBOX-3300MX Series user manual

DMP Electronics

DMP Electronics EBOX-3300MX Series user manual

Asus RS700-E9-RS4 user guide

Asus

Asus RS700-E9-RS4 user guide

Dell POWEREDGE R710 Getting started guide

Dell

Dell POWEREDGE R710 Getting started guide

Dell External OEMR R210II manual

Dell

Dell External OEMR R210II manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.