1

Other Cisco Server manuals

Cisco TelePresence Service manual

Cisco

Cisco TelePresence Service manual

Cisco 6400 User manual

Cisco

Cisco 6400 User manual

Cisco UCS B460 M4 User manual

Cisco

Cisco UCS B460 M4 User manual

Cisco UCS B200 M3 System manual

Cisco

Cisco UCS B200 M3 System manual

Cisco C880 M4 User manual

Cisco

Cisco C880 M4 User manual

Cisco C880 M5 User manual

Cisco

Cisco C880 M5 User manual

Cisco UCS C250 Installation and maintenance instructions

Cisco

Cisco UCS C250 Installation and maintenance instructions

Cisco CSACS-1121-K9 User manual

Cisco

Cisco CSACS-1121-K9 User manual

Cisco C220 M3 Manual

Cisco

Cisco C220 M3 Manual

Cisco Nexus 7000 Series User manual

Cisco

Cisco Nexus 7000 Series User manual

Cisco SCE8000 GBE Operator's manual

Cisco

Cisco SCE8000 GBE Operator's manual

Cisco UCS C3160 Installation and maintenance instructions

Cisco

Cisco UCS C3160 Installation and maintenance instructions

Cisco UCS User manual

Cisco

Cisco UCS User manual

Cisco UCS C220 M4 User manual

Cisco

Cisco UCS C220 M4 User manual

Cisco UCS B420 M4 User manual

Cisco

Cisco UCS B420 M4 User manual

Cisco UCS C220 M3 User manual

Cisco

Cisco UCS C220 M3 User manual

Cisco SCE2020-4XGBE-SM User manual

Cisco

Cisco SCE2020-4XGBE-SM User manual

Cisco UCS C220 Installation and maintenance instructions

Cisco

Cisco UCS C220 Installation and maintenance instructions

Cisco UCS B200 M3 Manual

Cisco

Cisco UCS B200 M3 Manual

Cisco Sourcefire Defense Center 750 User manual

Cisco

Cisco Sourcefire Defense Center 750 User manual

Cisco C880 M5 User manual

Cisco

Cisco C880 M5 User manual

Cisco UCS C460 M4 Installation and operation manual

Cisco

Cisco UCS C460 M4 Installation and operation manual

Cisco UCS 5100 Manual

Cisco

Cisco UCS 5100 Manual

Cisco UCS 5100 Manual

Cisco

Cisco UCS 5100 Manual

Popular Server manuals by other brands

HP Tc2120 - Server - 256 MB RAM installation guide

HP

HP Tc2120 - Server - 256 MB RAM installation guide

Lenovo ThinkServer RD230 manual

Lenovo

Lenovo ThinkServer RD230 manual

Avocent CPS810 Installer/user guide

Avocent

Avocent CPS810 Installer/user guide

Dell PowerEdge R6615 Installation and service manual

Dell

Dell PowerEdge R6615 Installation and service manual

FreeWave HT2+ installation guide

FreeWave

FreeWave HT2+ installation guide

GIGA-BYTE TECHNOLOGY G492-Z50 user manual

GIGA-BYTE TECHNOLOGY

GIGA-BYTE TECHNOLOGY G492-Z50 user manual

Lanner HTCA-E400 user manual

Lanner

Lanner HTCA-E400 user manual

Bull NovaScale T840 E2 user guide

Bull

Bull NovaScale T840 E2 user guide

Asus RS740-E70RS24-EG Configuration guide

Asus

Asus RS740-E70RS24-EG Configuration guide

Meinberg LANTIME M300/TCR manual 

Meinberg

Meinberg LANTIME M300/TCR manual 

HP ProLiant SL335s G7 Maintenance and service guide

HP

HP ProLiant SL335s G7 Maintenance and service guide

ZyXEL Communications VANTAGE RADIUS 50 user guide

ZyXEL Communications

ZyXEL Communications VANTAGE RADIUS 50 user guide

Lantronix xDirect-IAP quick start guide

Lantronix

Lantronix xDirect-IAP quick start guide

Fujitsu PRIMEQUEST 2400E3 General description

Fujitsu

Fujitsu PRIMEQUEST 2400E3 General description

IBM 9040-MR9 manual

IBM

IBM 9040-MR9 manual

IBM 306m - eServer xSeries - 8849 user guide

IBM

IBM 306m - eServer xSeries - 8849 user guide

green hippo Hippotizer Nevis+ quick start guide

green hippo

green hippo Hippotizer Nevis+ quick start guide

IBM 8203-E4A Brochure & specs

IBM

IBM 8203-E4A Brochure & specs

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick Reference
Cisco ONS 15454 SONET and SDH TL1 Command Quick
Reference Guide, Release 4.7
This guide lists TL1 commands and autonomous messages by category. It includes basic
descriptions and input and output formats supported by Cisco ONS 15454 and
Cisco ONS 15454 SDH, Release 4.7.
TL1 commands conform to the following syntax:
a:b:c:d:e: ...z;
where:
“a” is the Command Code
“b” is the Target Identifier (TID)
“c” is the Access Identifier (AID) or the User Identifier (UID)
“d” is the Correlation Tag (CTAG)
“e: ...z;” are other positions required for various commands
The TID, AID, and CTAG parameters route and control the TL1 command.
The remaining parameters provide additional information required to complete
the action requested by the command.
2
1 DWDM
Ta b l e 1 DW D M
COPY-RFILE:[<TID>]:[<SRC>]:<CTAG>::TYPE=<XFERTYPE>,[SRC=<SRC1>,]
[DEST=<DEST>,][OVWRT=<OVWRT>,][FTTD=<FTTD>];
Downloads a new software package or file from the location specified by the FTP URL.
DLT-EQPT:[<TID>]:<AID>:<CTAG>[:::];
Deletes a card from the Network Element (NE).
DLT-LNK-<MOD2O>:[<TID>]:<FROM>,<TO>:<CTAG>;
Deletes an optical link between two optical connection points.
DLT-OSC:[<TID>]:<AID>:<CTAG>;
Deletes the Optical Service Channel (OSC) group of the NE.
DLT-<PAYLOAD>:[<TID>]:<AID>:<CTAG>;
Deletes a port connection from a client port to a supported payload type.
DLT-WLEN:[<TID>]:<AID>:<CTAG>:::[CMDMDE=<CMDMDE>][:];
Deletes the provisioned wavelength (WLEN).
ED-10GIGE:[<TID>]:<AID>:<CTAG>:::[NAME=<PORTNAME>,][MACADDR=<MACADDR>]:
[<PST>],[<SST>];
Edits the 10 GBit/sec parameters for the 10GIGE port.
ED-ALS:[<TID>]:<AID>:<CTAG>:::[ALSMODE=<ALSMODE>,][ALSRCINT=<ALSRCINT>,]
[ALSRCPW=<ALSRCPW>,][:];
Edits the Automatic Laser Shutdown (ALS) attributes of an OC-N facility and all facilities that
support the ALS feature.
ED-APC:[<TID>]::<AID>::<CTAG>:::[APC-ENABLE=<APCENABLE>][:];
Edits Amplification Power Control (APC) application attributes.
ED-ESCON:[<TID>]:<AID>:<CTAG>:::[ENCAP=<ENCAP>,][CMDMDE=<CMDMDE>][:]
[<PST>[,<SST>]];
Edits the attributes for an Enterprise System Connection (ESCON) interface.
ED-EQPT:[<TID>]:<AID>:<CTAG>:::[PEERID=<PEERID>,]
[REGENNAME=<REGENNAME>,][PWL=<PWL>,][CARDMODE=<CARD_MODE>];
Edits the attributes for a given equipment slot in the NE. If the card is in an equipment slot, this
command is allowed only on the working AID.
ED-FFP-OCH::[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>,][RVRTV=<RVRTV>,]
[RVTM=<RVTM>,][PSDIRN=<PSDIRN>][:];
Edits the provisioning for the default protection group on the DWDM port of a TXP_MR_2.5G or
TXPP_MR_2.5G card.
3
ED-GIGE:[<TID>]:<AID>:<CTAG>:::[ENCAP=<ENCAP>,][CMDMDE=<CMDMDE>[:]
[<PST>[<,<SST>]];
Edits the Gigabit Ethernet-specific parameters for the port.
ED-LNK-<MOD2O>:[<TID>]:<FROM>,<TO>:<CTAG>::::<PST>,[<SST>];
Edits an optical link.
ED-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>,]
[CMDMDE=<CMDMDE>]:<PST>,[<SST>];
Edits the operating parameters for a DWDM facility.
ED-OCH:[<TID>]:<AID>:<CTAG>:::[NAME=<PORTNAME>,][SFBER=<SFBER>,]
[SDBER=<SDBER>,][ALSMODE=<ALSMODE>,][ALSRCINT=<ALSRCINT>,]
[ALSRCPW=<ALSRCPW>,][COMM=<COMM>,][GCCRATE=<GCCRATE>,]
[OSDBER=<OSDBER>,][DWRAP=<DWRAP>,][FEC=<FEC>,]
[PAYLOAD-MAP=<PAYLOADMAP>,][RLASER=<RLASER>,][SOAK=<SOAK>]:[<PST>],
[<SST>];
Edits the operating parameters of an Optical Channel (OCH) facility.
ED-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[NAME=<PORTNAME>,][DCC=<DCC>,]
[GCC=<GCC>,][AREA=<AREA>,][SYNCMSG=<SYNCMSG>,][SENDDUS=<SENDDUS>,]
[PJMON=<PJMON>,][SFBER=<SFBER>,][SDBER=<SDBER>,][MODE=<MODE>,]
[MUX=<MUX>,][SOAK=<SOAK>,][OSPF=<OSPF>,][LDCC=<LDCC>,][NAME=<NAME>,]
[EXPTRC=<EXPTRC>,][TRC=<TRC>,][TRCMODE=<TRCMODE>,]
[TRCFORMAT=<TRCFORMAT>,][CMDMDE=<CMDMDE>]:<PST>,[<SST>];
Edits the attributes (service parameters) and state of an OC-N facility.
ED-OMS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>,][EXPBAND=<EXPBAND>,]
[VOAATTN=<VOAATTN>,][VOAPWR=<VOAPWR>,][CALOPWR=<CALOPWR>,]
[CHPOWER=<CHPOWER>]:[<PST>],[<SST>];
Edits the attributes (service parameters) and state of an Optical Multiplex Section (OMS) facility.
ED-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>,][NODEID=<NODEID>];
Edits the Optical Service Channel (OSC) group attributes.
ED-OTS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>,][VOAATTN=<VOAATTN>,]
[VOAPWR=<VOAPWR>,][OFFSET=<OFFSET>,][CALTILT=<CALTILT>,][OSRI=<OSRI>,]
[AMPLMODE=<AMPLMODE>,][CHPOWER=<CHPOWER>,][EXPGAIN=<EXPGAIN>,]
[NAME=<NAME>,][CMDMDE=<CMDMDE>]:[<PST>],[<SST>];
Edits the attributes (service parameters) and state of an OTS facility.
ED-SLV-WDMANS:[<TID>]:[<AID>]:<CTAG>:::[HIGHSLVEXP=<HIGHSLVEXP>,]
[LOWSLVEXP=<LOWSLVEXP>][:];
Provisions the expected span loss verification.
Table 1 DWDM (continued)
4
ED-TRC-OCH:[<TID>]:<SRC>:<CTAG>:::[EXPTRC=<EXPTRC>,][TRC=<TRC>,]
[TRCMODE=<TRCMODE>,][TRCLEVEL=<TRCLEVEL>,][TRCFORMAT=<TRCFORMAT>][:];
Edits trace-related optical channel facilities.
ED-WDMANS:[<TID>]:<AID>:<CTAG>:::[POWERIN=<POWERIN>,]
[POWEROUT=<POWEROUT>,][POWEREXP=<POWEREXP>,][NTWTYPE=<RINGTYPE>,][:];
Edits the optical node setup application attributes.
ED-WLEN:[<TID>]:<AID>:<CTAG>:::[SIZE=<SIZE>]:[<PST>],[<SST>];
Edits wavelength (WLEN) provisioning.
ENT-EQPT:[<TID>]:<AID>:<CTAG>::[<EQPTTYPE>]:[PEERID=<PEERID>,]
[REGENNAME=<REGENNAME>,][PWL=<PWL>,][CARDMODE=<CARD_MODE>];
Creates the card type and attributes for a given equipment slot in the NE. It also automatically enters
all facilities supported by the card, assigning default values to all port and path attributes.
ENT-LNK-<MOD2O>:[<TID>]:<FROM>,<TO>:<CTAG>::::<PST>,[<SST>];
Creates an optical link between two optical connection points.
ENT-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>,]NODEID=<NODEID>,]
[EAST=<EAST>,][WEST=<WEST>];
Creates the OSC (optical service channel) group of the NE.
ENT-<PAYLOAD>:[<TID>]:<AID>:<CTAG>;
Creates a port connection from a client port to a supported payload type.
ENT-WLEN:[<TID>]:<AID>:<CTAG>::[<WCT>]:[SIZE=<SIZE>]:[<PST>],[<SST>];
Allocates a wavelength.
INIT-REG-<MOD2>:[<TID>]:<AID>:<CTAG>::<MONTYPE>,,[<LOCN>],[<DIRN>],
[<TMPER>][,,];
Initializes the performance monitoring registers on an OMS card.
OPR-ALS:[<TID>]:<AID>:<CTAG>[:::::];
Restarts the laser of an OC-N facility and all facilities that support the ALS feature.
OPR-APC:[<TID>]::<CTAG>[::::];
Permits the Amplifier Power Control (APC) application inside the NE to force regulation of the
optical power to the entire DWDM ring.
OPR-LNK:[<TID>]::<CTAG>;
Permits the optical link application inside the NE to calculate all the automatic optical links between
end points that can be univocally identified by the NE.
OPR-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>[::];
Performs a protection switch on the trunk port of a TXPP_MR_2.5G card.
Table 1 DWDM (continued)
5
OPR-SLV-WDMANS:[<TID>]:<AID>:<CTAG>[::::];
Invokes the calculation of the expected span loss verification.
OPR-WDMANS:[<TID>]::<CTAG>;
Operates the Automatic Optical Node Setup (AONS) application inside the NE to force a recompute
of the value to be assigned to all variable optical attenuators (VOAs) representing the Optical Path
inside the node.
RLS-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>[::];
Performs a protection switch on the trunk port of a TXPP_MR_2.5G card.
RMV-<MOD2_IO>:[<TID>]:<AID>:<CTAG>::[<CMDMODE>],[<PST>],[<SST>];
Removes a facility from service.
RST-<MOD2_IO>:[<TID>]:<AID>:<CTAG>[::];
Provisions a facility in-service.
RTRV-10GIGE:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the 10 GBit/sec parameters for the 10GIGE port.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::[NAME=<PORTNAME>,][MACADDR=<MACADDR>,][LBCL=<LBCLCURR>,]
[OPT=<OPTCURR>,][OPR=<OPRCURR>]:<PST>,[<SST>]”
;
RTRV-ALM-ALL:[<TID>]::<CTAG>::[<NTFCNCDE>],[<CONDITION>],[<SRVEFF>][,,,];
Retrieves and sends the current status of all active alarm conditions.
Output format:
SID DATE TIME
M CTAG COMPLD
“[<AID>],[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>],[<AIDDET>]”
;
RTRV-ALM-EQPT:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],
[<SRVEFF>][,,,];
Retrieves and sends the current status of alarm conditions associated with the equipment units.
Output format:
SID DATE TIME
M CTAG COMPLD
“[<AID>],[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>]”
;
Table 1 DWDM (continued)
6
RTRV-ALM-<MOD2ALM>:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],
[<SRVEFF>][,,,];:
Instructs the NE to retrieve and send the current status of an alarm condition.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,
:[<DESC>]”
;
RTRV-ALMTH-<MOD2>:[<TID>]:<AID>:<CTAG>::<ALMTHR>[,,::];
Retrieves the alarm threshold values.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<MOD>:<CONDTYPE>,,,<THLEVEL>”
;
RTRV-ALS:[<TID>]:<AID>:<CTAG>[:::::];
Retrieves the ALS attributes of an OC-N facility and all facilities that support the ALS feature.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<AIDTYPE>::[ALSMODE=<ALSMODE,>][ALSRCINT=<ALSRCINT>,]
[ALSRCPW=<ALSRCPW>,][LSRSTAT=<LSRSTAT>]:”
;
RTRV-APC:[<TID>]::<AID>::<CTAG>[::::];
Retrieves the APC application attributes.
Output format:
SID DATE TIME
M CTAG COMPLD
“::[APCENABLE=<APCENABLE>,][APCSTATE=<APCSTATE>][:]”
;
Table 1 DWDM (continued)
7
RTRV-COND-ALL:[<TID>]::<CTAG>::[<TYPEREQ>][,,,];
Retrieves the current standing condition for all entities.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],[<OCRDAT>],
[<OCRTM>],,,[<DESC>]”
;
RTRV-COND-EQPT:[<TID>]:<AID>:<CTAG>::[<TYPEREQ>][,,,];
Retrieves the equipment conditions.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],[<OCRDAT>],
[<OCRTM>],,,[<DESC>]”
;
RTRV-COND-<MOD2ALM>:[<TID>]:<AID>:<CTAG>::[<TYPEREQ>][,,,];
Retrieves the current standing condition or/and state associated with an entity.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],[<OCRDAT>],
[<OCRTM>],,,[<DESC>]”
;
RTRV-ESCON:[<TID>]:<AID>:<CTAG>;
Retrieves the attributes for an ESCON interface.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::[NAME=<PORTNAME>,]ENCAP=<ENCAP>:<PST>,<SST>”
;
Table 1 DWDM (continued)
8
RTRV-EQPT:[<TID>]:<AID>:<CTAG>;
Retrieves card level attributes.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>:<EQPTTYPE>,<EQUIP>,[<ROLE>],[<STATUS>]:[PROTID=<PROTID>,]
[PRTYPE=<PRTYPE>,][RVRTV=<RVRTV>,][RVTM=<RVTM>,]
[CARDNAME=<CARDNAME>,][PEERID=<PEERID>,][REGENNAME=<REGENNAME>,]
[PWL=<PWL>,][CARDMODE=<CARD_MODE>:]<PST>],[<SST>]”
;
RTRV-FAC:[<TID>]:<SRC>:<CTAG>[::::];
Retrieves facility data (port data).
Output format:
SID DATE TIME
M CTAG COMPLD
"<SRC>::PAYLOAD=<PAYLOAD>:<PST_PSTQ>,[<SSTQ>]"
;
RTRV-FFP-OCH:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the protection group information for the TXPP_MR_2.5G trunk port.
Output format:
SID DATE TIME
M CTAG COMPLD
“<WORK>,<PROTECT>::[PROTTYPE=<PROTTYPE>,][PROTID=<PROTID>,]
[RVRTV=<RVRTV>,][RVTM=<RVTM>,][PSDIRN=<PSDIRN>]”
;
RTRV-GIGE:[<TID>]:<AID>:<CTAG>;
Retrieves the Gigabit Ethernet-specific parameters for the port.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>::[ADMINSTATE=<ADMINSTATE>,][LINKSTATE=<LINKSTATE>,]
[MTU=<MTU>,][FLOWCTRL=<FLOWCTRL>,][OPTICS=<OPTICS>,]
[DUPLEX=<DUPLEX>,][SPEED=<SPEED>,][ENCAP=<ENCAP>]:<PST>[SST>]”
;
Table 1 DWDM (continued)
9
RTRV-INV:[<TID>]:<AID>:<CTAG>[::::];
Queries the NE and returns a listing of the equipment inventory. For each unit in the system, it
identifies the unit’s firmware numbers and the unit’s Common Language Equipment Identification
(CLEI) code.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<AIDTYPE>::[PN=<PN>],[HWREV=<HWREV>],[FWREV<FWREV>],
[SN=<SN>],[CLEI=<CLEI>],[TWL1=<TWL1>],[TWL2=<TWL2>],[TWL3=<TWL3>],
[TWL4=<TWL4>]””
;
RTRV-LNK:[<TID>]::<CTAG>;
Retrieves all the optical links created in the NE.
Output format:
SID DATE TIME
M CTAG COMPLD
“<FROM>,<TO>::[OLNKT=<OLNKT>,][CTYPE=<CTYPE>,][RDIRN=<RDIRN>,]
[BAND=<BAND>,][WLEN=<WLEN>]:<PST>,[<SST>]”
;
RTRV-LNK-<MOD2O>:[<TID>]:<AID>:<CTAG>:::[OLNKT=<OLNKT>,][CTYPE=<CTYPE>,]
[RDIRN=<RDIRN>];
Retrieves any optical link associated with the entered AIDs or AID range.
Output format:
SID DATE TIME
M CTAG COMPLD
“<FROM>,<TO>::[OLNKT=<OPTICALLINKTYPE>,][CTYPE=<CREATIONTYPE>,]
[RDIRN=<RDIRN>,][BAND=<BAND>,][WLEN=<WLEN>]:<PST>,[<SST>]”
;
RTRV-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the configuration parameters of a DWDM Client.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<AIDTYPE>::[NAME=<NAME>,][LBCL=<LBCL>,][OPT=<OPT>,][OPR=<OPR>]:
<PST_PSTQ>,[<SST>]”
;
Table 1 DWDM (continued)
10
RTRV-NE-APC:[<TID>]::<CTAG>;
Retrieves the APC application ports that are involved in node setup regulation.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<AIDTYPE>::[MODIFDAT=<MODIFDAT>,][MODIFTM=<MODIFTM>,]
[CHECKDAT=<CHECKDAT>,][CHECKTM=<CHECKTM>, [:]”
;
RTRV-NE-WDMANS:[<TID>]:[<AID>]:<CTAG>[::::];
Retrieves the optical node setup application ports involved in node setup regulation.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>,<AIDTYPE>::[REGULATED=<REGULATED,>][PARAM=<PARAM>][:]”
;
RTRV-OCH:[<TID>]:<AID>:<CTAG>;
Retrieves the attributes (service parameters) and state of an OCH facility.
Output format:
SID DATE TIME
M CTAG COMPLD
“<AID>:,,,[<STATUS>]:[NAME=<PORTNAME>,][SFBER=<SFBER>,]
[SDBER=<SDBER>,][ALSMODE=<ALSMODE>,][ALSRCINT=<ALSRCINT>,]
[ALSRCPW=<ALSRCPW>,][COMM=<COMM>,][GCCRATE=<GCCRATE>,]
[DWRAP=<DWRAP>,][FEC=<FEC>,][PAYLOAD-MAP=<PAYLOADMAP>,]
[OFSBER=<OFSBER>][OSDBER=<OSDBER>][MACADDR=<MACADDR>,]
[SYNCMSG=<SYNCMSG>,][SENDDUS=<SENDDUS>,][LSRSTAT=<LSRSTAT>,]
[LBCL=<LBCL>,][OPT=<OPT>,][OPR=<OPR>][SOAK=<SOAK>]:,PST>,[<SST>]”
;
Table 1 DWDM (continued)