manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Clevertronics
  6. •
  7. Light Fixture
  8. •
  9. Clevertronics Trade EBS4N-LI Installation and operating instructions

Clevertronics Trade EBS4N-LI Installation and operating instructions

1948758
V1.1
13 January 2022
Instruction Sheet Template - V1.2 –Updated 06/10/2021
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
Trade Series Non-Maintained Batten
Surface Mount Emergency Luminaire
Installation & Maintenance Instruction Leaflet
Victoria (Head Office & Manufacturing)
Website: www.clevertronics.com.au
Email: info@clevertronics.com.au
Phone: +61 3 9559 2700
Fax: +61 3 9559 2799
New South Wales
Phone: +61 2 8805 6400
Fax: +61 2 8805 6444
Queensland
Phone: +61 7 3442 9700
Fax: +61 7 3442 9777
South Australia/Northern Territory
Phone: +61 8 8301 8800
Fax: +61 8 8351 8286
Western Australia
Phone: +61 8 9207 0000
Fax: +61 8 9207 0088
New Zealand
Phone: +64 800 548 448
Designed in Australia to comply with the requirements
of AS2293.3: 2005 and AS/NZS CISPR15: 2017
Models:
EBS4N-LI
Spare Parts:
1560150
Battery, EcoLith3.2V 3Ah
1100875
ELIFE-X-LI Head Assembly, Inc Adaptor Ring
ELIFE-X-LI-CKIT
Lifelight, Control Only, 3.0Ah, No Plug
Important:
It is illegal for anyone, except for a licensed electrician to install or maintain this product. Before installation,
ensure that the electricity supply has been switched off and isolated. Installation must be carried out in
accordance with the relevant Australian and International Standards.
1948758
V1.1
13 January 2022
Instruction Sheet Template - V1.2 –Updated 06/10/2021
Installation:
This EBS4N-LI Surface mount non-maintained Emergency Luminaire can be installed on solid surface
or used to replace an existing unit.
•Locate the installation position.
•Refer Images and Dimensions below for the Cut-out Hole and other dimensions.
•Pre-drill mounting holes
•Mount base plate and use suitable fixings to secure the base plate into the pilot holes
•Bring in supply cables via the rear entry hole or via the end of the base plate (surface mount
conduit entry)
•Terminate the supply cables to the L, N & E terminals
•Install the top cover, containing the control gear, ensuring to reconnect the control gear assembly
to the connector from the supply terminal block
•Ensure the Battery is connected
•Screw the cover to the base plate and, in the case of side/conduit entry remove the knock-out at
the end of the cover to go cover the conduit
Dimensions:
Testing:
When the EBS4N-LI unit is connected to the un-switched active, it must be allowed to charge the battery
for at least 24 hours. The emergency lamp only illuminates during a power failure. Conduct the following
tests:
•During the first commissioning test the emergency lamp must illuminate for at least 2 hours after
disconnection from the main supply. The results of all tests are required to be recorded in a service
logbook, which is to be kept on-site at all times. If the unit fails to illuminate for the requisite time,
remedial action must be taken to repair the situation and once completed, the unit must pass a
subsequent test.
•Press and hold Test Button for each LED head or switch Off Mains Supply, check that the
emergency lamps are On.
•Release the Test Button or Switch on Mains Supply, check that the emergency lamp is Off (Non-
maintained operation).
Trouble Shooting:
Below are a list of common problems and their possible causes.
Fault: The Green LED Test Switch indicator is not illuminated.
Check: A.C. is connected and is turned on.
Battery is connected
Test Switch for damage.
Fault: Lamp does not illuminate in emergency mode.
Check: A.C. is connected.
Lamp is correctly inserted.
Battery is connected
Fault: Lamp illuminates in emergency mode, but only stays on for a short period.
Check: Battery has been allowed to charge for at least 24 hours.
Battery for damage.
Rated Emergency Lumen Output in accordance with AS2293.1, not applicable
for –TH (theatre) version (refer to spacing tables for installation positions):
Refer to the Technical Label for classification information.
Caution:
On many building sites, power circuits may be cut off in an uncontrolled and repetitive basis during
construction. As a result, any Exit & Emergency Units, on these circuits, will have their batteries
discharged or “cycled”. The battery in this fitting has been selected to give excellent long-life
performance in a controlled AS2293 testing environment. Excessive battery cycling will reduce through-
life performance and may lead to premature battery failure. Battery warranty claims, as a result of such
abuse, are specifically EXCLUDED from Clevertronics warranty terms.
Warranty:
For Product Warranty information and Terms and Conditions of Sales please refer to our website
http://clevertronics.com.au/terms-conditions-sale-australia-nz/
Cable entry points
End view
Chain suspension points
Surface suspension points

Other Clevertronics Light Fixture manuals

Clevertronics L10 LIFELIGHT PRO LWPLIFEz-PRO Series Manual

Clevertronics

Clevertronics L10 LIFELIGHT PRO LWPLIFEz-PRO Series Manual

Popular Light Fixture manuals by other brands

TE-Group DreamLED RFIC-40 user manual

TE-Group

TE-Group DreamLED RFIC-40 user manual

Lightolier DMP01 specification

Lightolier

Lightolier DMP01 specification

Lightolier Lytecaster 1113IE specification

Lightolier

Lightolier Lytecaster 1113IE specification

Scanic LED LASER BAR DMX instruction manual

Scanic

Scanic LED LASER BAR DMX instruction manual

Current Compass CU2FO quick start guide

Current

Current Compass CU2FO quick start guide

Larson Electronics EPL-AMB-150LED-200 instruction manual

Larson Electronics

Larson Electronics EPL-AMB-150LED-200 instruction manual

Leuze electronic 50138252 manual

Leuze electronic

Leuze electronic 50138252 manual

Cooper Lighting Portfolio HD7500QT4 installation instructions

Cooper Lighting

Cooper Lighting Portfolio HD7500QT4 installation instructions

SImx LHT1115 installation instructions

SImx

SImx LHT1115 installation instructions

Westinghouse w-023 owner's manual

Westinghouse

Westinghouse w-023 owner's manual

Lucci LEDlux 220822, 220823 installation instructions

Lucci LEDlux

Lucci LEDlux 220822, 220823 installation instructions

Conrad 57 76 65 operating instructions

Conrad

Conrad 57 76 65 operating instructions

Lightolier Calculite C6T6A-MHT6RF specification

Lightolier

Lightolier Calculite C6T6A-MHT6RF specification

Toplicht DHR 180 Mounting instructions

Toplicht

Toplicht DHR 180 Mounting instructions

Hunter Rosette Owner's guide and installation manual

Hunter

Hunter Rosette Owner's guide and installation manual

Cooper Lighting Metalux I5455 Specifications

Cooper Lighting

Cooper Lighting Metalux I5455 Specifications

STEINEL studioline operating instructions

STEINEL

STEINEL studioline operating instructions

Jandy JandyColors JPL1230 Installation and operation manual

Jandy

Jandy JandyColors JPL1230 Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.