OPERATING INSTRUCTIONS MCM350 PORTABLE AIR CONDITIONER
Page 5
TROUBLESHOOTING GUIDE
ALWAYS CONSULT THIS GUIDE BEFORE RINGING YOUR SUPPLIER; THE MAJORITY OF REPORTED PROB-
LEMS ARE SIMPLY SOLVED IN THIS MANNER
PROBLEM POSSIBLE CAUSE SOLUTION
UNIT FAILS TO OPERATE
POWER FAILURE CHECK ‘POWER ON’ LIGHT IS LIT
CHECK UNIT IS PLUGGED IN TO POWER
SUPPLY
CHECK PLUG FUSE FOR FAILURE &
CORRECT 13 AMP RATING
CHECK BUILDING RING CIRCUIT IS NOT
OVERLOADED
‘TANK FULL’ LIGHT ON EMPTY WATER TANK
POOR COOLING PERFORMANCE
COOLING NOT SELECTED PRESS COOLING ON ROCKER SWITCH
THERMOSTAT KNOB NOT TURNED FULLY
ANTI-CLOCKWISE
TURN KNOB FULLY ANTICLOCKWISE,
COMPRESSOR HAS 4 MINUTE DELAY
BEFORE IT STARTS. COOLING WILL
COMMENCE A TER APPROX 10 MINUTES
COILS DIRTY BLOW COMPRESSED AIR THROUGH
COILS TO CLEAN
FILTERS DIRTY (WHERE FITTED) WASH OR REPLACE FILTERS
EXHAUST HOSE TOO LONG, KINKED,
OUTLET RESTRICTED OR BLOCKED,
RESULTING IN HEAT NOT BEING
REMOVED FROM THE FRIDGE CIRCUIT
CAUSING CIRCUIT TEMPERATURE TO
RISE & COOLING PERFORMANCE TO
FALL
ENSURE ONLY THE QUOTED MAXIMUM
LENGTH DUCT IS USED & THAT IT
IS STRAIGHT, KEPT TAUT & EXITS
PROPERLY TO OUTSIDE
AIR INLET GRILLS OBSTRUCTED REMOVE OBSTRUCTION
FAN SPEED ON LOW SETTING TURN FAN SPEED TO MED OR HIGH
WATER LEAKAGE
CLOGGED DRAIN TUBE REMOVE BLOCKAGE
WATER TANK MISSING REPLACE TANK
TANK FULL, AND AUTO CUT-OUT NOT
WORKING CORRECTLY
CHECK TANK TRAY OPERATES FREELY
DEPRESS MICROSWITCH LEVER ARM,
UNIT SHOULD STOP & ‘TANK FULL’ LIGHT
SHOULD BE LIT
HOSE NOT LOCATED IN TANK
CORRECTLY
ENSURE HOSE IS LOCATED INTO TANK
COMPRESSOR STOPS RUNNING INPUT VOLTAGE TOO LOW CHECK LINE VOLTAGE
WATER TANK FULL CHECK THAT TANK IS NOT FULL
AS FOR POOR PERFORMANCE
IF NONE OF THE ABOVE SOLVES THE PROBLEM, CONTACT SUPPLIER.