3
INSTRUCTIONS
1. Choose a firm, flat and level location next to the structure. The unit must be within 4’(48”)
of the structure (closer, if there will be bends in the air hose) and 8’to a 120V power outlet.
The closer the unit is to the structure, the better the airflow will be. (See Figure 2.1)
2. Place the ClimateRight unit at the chosen location. Orient the unit with the Air Inlet and
Outlet toward the structure and the display panel away from the structure.
Note: It is important to face the control panel toward an area from which the remote
control will be used, but do not turn the unit so the air hoses will bend more than 90
degrees. This will degrade airflow and heating and cooling capacity. All control functions
will be performed from the remote control.
3. Before marking locations to drill the holes for the flanges, make sure there are no electrical
wires, pipes or obstructions of any type behind the proposed drilling locations.
4. Find a location where the first hole will be located. The hole locations should not be placed
where objects could block the air flow. Mark the first location with a pencil.
5. The second hole location must be spaced a minimum of 12”diagonally from the first hole
location. Mark this location with a pencil. (See Figure 2.2)
6. With no obstructions behind the marked locations, drill out the holes with the 3-1/2”hole
saw.
7. Once the holes have been drilled, insert a ClimateRight Building Flange (D).
Note: If the building flange is too long, it can be cut to length. The grooves on the flange
are spaced at 1”intervals.
8. If necessary, mark the screw hole locations with a pencil and drill pilot holes for the screws.
(For #8 wood screws use a 5/64”drill bit)