16X8A Relay Module (CL-DR-RL16X8A)
Rail Mounting
16X8A Relay Module is designed to be installed on a standard
35 mm wide DIN rail (EN 50022, BS 5584).
Hook the module from the top, pull down the rail mounng
clips, push the module to the rail and release the rail
mounng clips.
Screw Mounting
Screw the module to any surface through 4 corner screw
holes.
3
4
1
2
INSTALLATION GUIDE version 1.0.1
Input Voltage
18V-24V DC (24V DC is recommended)
Input Current
320mA (for 24V DC)
I/O Connecons
C-Bus
2 X RJ45
Output
16 X relay channel -8A per Channel
(rising-cage 5mm screw terminals)
Product Specificaon
1. Screw holes
2. Output connectors
3.Rail mounng clips
4. Channel LEDs
5. Status LEDs
6. Control buons (1-16)
7. RS-485 jack
1
2
3
1
1
4
1
5
7
6
3
7
16x8A Relay Module
CL-DR-RL16X8A
Ch9Ch10Ch11Ch12Ch13Ch14Ch15Ch16
1
2
C-Bus
C-Bus
34
5
67
8
9
10
1112
13
14
1516
Com
1-4
Com
5-8
Com
9-12
Com
13-16
Power In: 24V DC, 320mA max, from data bus
4
Compatible with Control4
16x8A Relay Module
CL-DR-RL16X8A
Ch9Ch10Ch11Ch12Ch13Ch14Ch15Ch16
1
2
C-Bus
C-Bus
34
5
67
8
9
10
1112
13
14
1516
Com
1-4
Com
5-8
Com
9-12
Com
13-16
Power In: 24V DC, 320mA max, from data bus
#2
#3#4
#5
#8 #1
#6#7
C-Bus
C-Bus
#2
#3#4
#5
#8 #1
#6#7
12
3
Change Module Address
In order to change the module address follow steps below consecuvely and uninterruptedly:
1. Disconnect the main power. Hold buon #1 & #2 simultaneously (buon’s and LED’s number
sequence is considered from right to le as shown in following picture) .
2. Reconnect the main power. Release buon #2 aer LEDs #1 to #4 flashed. Then release buon #1
aer LEDs #1 and #2 flashed. Power LED will start flashing quickly.
3. Press buon #1, 4 mes. Then the module address will be displayed by LEDs in binary.
4. Press buon #1 to increase the module address and buon #2 to decrease it.
5. Press buon #3 to save the module address and buon #4 to cancel. Aer saving the new module
address or canceling the process, the module will reset.
The devices which are connected from a common interface cannot have same module
address.
To: Next Module
From: Previous Module
Main
N
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
123456 7 8 9 10 11 12 13 14 1515 16
Com
1-4 Com
5-8 Com
9-12 Com
13-16
57
68
Before wiring the device, always unplug the main power.
Follow this wiring to setup the module.
Follow the diagram below to apply appropriate output/input and protect module in case of
unwanted short circuit.
Enable/disable Autosave
If autosave funcon is acvated, reconnecng main power will set all outputs to the last status
(before power outage).
In order to enable/disable autosave follow steps below consecuvely and uninterruptedly:
1. Disconnect the main power. Hold buon #1 & #2 simultaneously (buon’s and LED’s number
sequence is considered from right to le as shown in page 4) .
2. Reconnect the main power. Release buon #2 aer LEDs #1 to #4 flashed. Then release buon
#1 aer LEDs #1 and #2 flashed. Power LED will start flashing quickly.
3. Press buon #2, 4 mes.
4. To disable/enable autosave mode, press buon #1. LED #1 will display whether autosave mode is
disabled or enabled. If it is “on” the autosave mode is enable.
5. Press buon #3 to save new seng and buon #4 to cancel.
It is recommended to disable autosave unless it is needed to be enabled.
Use one 10A fuse for every four channel.
Module’s LEDs
Power: “Power LED” will flash smoothly. When the module is connected to main power,
Status: “Status When the module is connected to C-Bus network and receives valid data packets,
LED” flashes quickly. “Status LED” is “of” when the module doesn’t receive any data.
When the module is receiving invalid data packet, “Status LED” will remain “on” for 5 seconds.
In some cases, when a new module is added to C-Bus network, all Status LEDs might remain
“on” for 5 seconds. This situaon must not be considered as an error.
Ch1 to Ch16: Shows the status of module’s relays. Also when the module is connected to main
power, the channel LEDs will display the module address in binary for 2 seconds.
Toggle Module’s Channels
Ch1 to Ch8: For toggling Ch1 to 8 press and hold buons 1# to 8# for less than 700 ms.
Ch9 to Ch16: For toggling Ch9 to 16 press and hold buons 1# to 8# for more than 700 ms. For
instance to toggle Ch14, press #6 for more than 700 ms.and hold buon
Ch9Ch10Ch11Ch12Ch13Ch14Ch15Ch16
C-Bus
C-Bus
#2
#3#4
#5
#8 #1
#6#7
Use the terminator socket for the last module in C-Bus network.

Other Climax Relay manuals

Climax CL-PK-MR2 User manual

Climax

Climax CL-PK-MR2 User manual

Climax CL-AB-5AMR2 User manual

Climax

Climax CL-AB-5AMR2 User manual

Climax CL-PK-CPMR2) User manual

Climax

Climax CL-PK-CPMR2) User manual

Climax CL-DR-RL8X8A-N User manual

Climax

Climax CL-DR-RL8X8A-N User manual

Popular Relay manuals by other brands

Marina Model GFR480-1 Installation and operation manual

Marina

Marina Model GFR480-1 Installation and operation manual

MRMC MRMC-2127-01 quick start guide

MRMC

MRMC MRMC-2127-01 quick start guide

Moeller ZB65 Series Hardware and engineering

Moeller

Moeller ZB65 Series Hardware and engineering

Ditel 2 RE user manual

Ditel

Ditel 2 RE user manual

LEGRAND LEXIC 047 43 quick start guide

LEGRAND

LEGRAND LEXIC 047 43 quick start guide

Chenzhu GS8547-EX user manual

Chenzhu

Chenzhu GS8547-EX user manual

Bticino 346230 instruction sheet

Bticino

Bticino 346230 instruction sheet

E.J.A. Engineering Guardmaster Minotaur MSR14T installation instructions

E.J.A. Engineering

E.J.A. Engineering Guardmaster Minotaur MSR14T installation instructions

SICK ReLy LOOP1 Mounting instructions

SICK

SICK ReLy LOOP1 Mounting instructions

LSIS EMPR Series manual

LSIS

LSIS EMPR Series manual

Relpol RSR72 User instruction

Relpol

Relpol RSR72 User instruction

Eaton ES4A-221-DMX-SIM installation instructions

Eaton

Eaton ES4A-221-DMX-SIM installation instructions

Leviton GreenMAX R16TC-100 manual

Leviton

Leviton GreenMAX R16TC-100 manual

Omron MK-SX - datasheet

Omron

Omron MK-SX - datasheet

Siemens 3UA66 instructions

Siemens

Siemens 3UA66 instructions

Honeywell R4343D instruction sheet

Honeywell

Honeywell R4343D instruction sheet

Siemens LZS PT Series operating instructions

Siemens

Siemens LZS PT Series operating instructions

Siemens siprotec 7SJ63 instruction manual

Siemens

Siemens siprotec 7SJ63 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.