manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Climax
  6. •
  7. Relay
  8. •
  9. Climax CL-PK-MR2 User manual

Climax CL-PK-MR2 User manual

Other Climax Relay manuals

Climax CL-DR-RL8X8A-N User manual

Climax

Climax CL-DR-RL8X8A-N User manual

Climax CL-DR-RL16X8A User manual

Climax

Climax CL-DR-RL16X8A User manual

Climax CL-AB-5AMR2 User manual

Climax

Climax CL-AB-5AMR2 User manual

Climax CL-PK-CPMR2) User manual

Climax

Climax CL-PK-CPMR2) User manual

Popular Relay manuals by other brands

Shelly Pro Series user manual

Shelly

Shelly Pro Series user manual

GE MVAX 11 Technical manual

GE

GE MVAX 11 Technical manual

ABB RELION REF615R manual

ABB

ABB RELION REF615R manual

Pilz PNOZ X10 Technical instructions

Pilz

Pilz PNOZ X10 Technical instructions

Kemo Electronic B197 quick guide

Kemo Electronic

Kemo Electronic B197 quick guide

Seg MRM3 manual

Seg

Seg MRM3 manual

Basler BE1-700C manual

Basler

Basler BE1-700C manual

CD Automation REVEX 2PH 280A user manual

CD Automation

CD Automation REVEX 2PH 280A user manual

ABB SPAJ 142 C User manual and technical description

ABB

ABB SPAJ 142 C User manual and technical description

Ruelco 1S04 Operation manual

Ruelco

Ruelco 1S04 Operation manual

Basler V3E Z1P B2C1F instruction manual

Basler

Basler V3E Z1P B2C1F instruction manual

Doepke Dupline DSM 2 operating instructions

Doepke

Doepke Dupline DSM 2 operating instructions

Siemens SIRIUS 3RT1966-4D Original operating instructions

Siemens

Siemens SIRIUS 3RT1966-4D Original operating instructions

GE DGP instruction manual

GE

GE DGP instruction manual

Kyongbo Electronics GDR-D01 user manual

Kyongbo Electronics

Kyongbo Electronics GDR-D01 user manual

Siemens SIPROTEC 4 user manual

Siemens

Siemens SIPROTEC 4 user manual

Siemens BD2-AK03X/FS Series installation instructions

Siemens

Siemens BD2-AK03X/FS Series installation instructions

Leuze MSI-SR5B Original operating instructions

Leuze

Leuze MSI-SR5B Original operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALLATION GUIDE version 1.0.6
2 Channel Micro Relay (CL-PK-MR2)
Product Specification
Input Voltage
18V-24V DC (24V DC is recommended)
Input Current
45 mA -60 mA
Load Type
2 x4A Relay (Approx. 800 watt per channel–for resistive load)
I/O Connections
C-BUS
4 x Rising-cage 5mm screw terminals
Output
2 channel x Rising-cage 5mm screw terminals
Input
2 channel control input
Junction Box
Climax 2 Channel Micro Relay is designed basically to be
installed in a junction box behind a two channel contact Keypad.
The product size must be considered when applying it in
junction boxes.
Product Size: 50L X 44W X 25.7H (mm)
Screw Mounting
Screw the 2 Channel Micro Relay to any surface through 2 side
screw holes.
For screw mounting following part number must be used:
CL-PK-MR2-S
Use following instruction to connect module on C-Bus with Cat6 cable:
Color
Color Name
Pin
C-Bus
Orange/White
1
A(DATA+)
Orange
2
B(DATA-)
Green/White
3
TXD*
Blue
4
RXD*
Blue/White
5
GND
Green
6
GND
Brown/White
7
VCC
Brown
8
VCC
* TXD & RXD will be used only in direct mode application of module.
Change Device Address
The device address can be set from 0 to 31 by mean of a dip switch called
“address selector switch”. Before changing address the main power must be
disconnected. The address must be defined in binary. For instance for setting
address to “21” the address selector switch must be as bellow:
Never set the address to 0 and 1 as 0 is not valid in C-Bus protocol and 1 is
always dedicated for RS-232 GatewayPro module. Check all C-Bus modules
address to avoid repetitive address allocation.
Channel Toggling
Each channel can be toggled by connecting/disconnecting COM & corresponding
input on control pins.
Module LED’s
Upon connecting the main power, the green Power LED will start flashing.
The green Status LED flashes any time a valid data packet received to the micro relay.
In case of receiving invalid data packet in C-Bus connections, the Status LED will turn
on for 5 seconds.
At the time of connecting modules to each other Status LEDs might be turned on for 5
seconds while it must not be considered as an error.
Before wiring the device, always unplug the main power.
Before adding a new module on the C-Bus, ensure the previous module has a valid address
and is working properly.
In case of using capacitive or inductive loads, permissible current is less than normal mode
(resistive load) depending on load condition.
Follow the diagram below in order to apply right input/output and connect modules to
each other.