INSTALLATION GUIDE version 1.0.6
2 Channel Micro Relay (CL-PK-MR2)
Product Specification
Input Voltage
18V-24V DC (24V DC is recommended)
Input Current
45 mA -60 mA
Load Type
2 x4A Relay (Approx. 800 watt per channel–for resistive load)
I/O Connections
C-BUS
4 x Rising-cage 5mm screw terminals
Output
2 channel x Rising-cage 5mm screw terminals
Input
2 channel control input
Junction Box
Climax 2 Channel Micro Relay is designed basically to be
installed in a junction box behind a two channel contact Keypad.
The product size must be considered when applying it in
junction boxes.
Product Size: 50L X 44W X 25.7H (mm)
Screw Mounting
Screw the 2 Channel Micro Relay to any surface through 2 side
screw holes.
For screw mounting following part number must be used:
CL-PK-MR2-S
Use following instruction to connect module on C-Bus with Cat6 cable:
Color
Color Name
Pin
C-Bus
Orange/White
1
A(DATA+)
Orange
2
B(DATA-)
Green/White
3
TXD*
Blue
4
RXD*
Blue/White
5
GND
Green
6
GND
Brown/White
7
VCC
Brown
8
VCC
* TXD & RXD will be used only in direct mode application of module.
Change Device Address
The device address can be set from 0 to 31 by mean of a dip switch called
“address selector switch”. Before changing address the main power must be
disconnected. The address must be defined in binary. For instance for setting
address to “21” the address selector switch must be as bellow:
Never set the address to 0 and 1 as 0 is not valid in C-Bus protocol and 1 is
always dedicated for RS-232 GatewayPro module. Check all C-Bus modules
address to avoid repetitive address allocation.
Channel Toggling
Each channel can be toggled by connecting/disconnecting COM & corresponding
input on control pins.
Module LED’s
Upon connecting the main power, the green Power LED will start flashing.
The green Status LED flashes any time a valid data packet received to the micro relay.
In case of receiving invalid data packet in C-Bus connections, the Status LED will turn
on for 5 seconds.
At the time of connecting modules to each other Status LEDs might be turned on for 5
seconds while it must not be considered as an error.
Before wiring the device, always unplug the main power.
Before adding a new module on the C-Bus, ensure the previous module has a valid address
and is working properly.
In case of using capacitive or inductive loads, permissible current is less than normal mode
(resistive load) depending on load condition.
Follow the diagram below in order to apply right input/output and connect modules to
each other.

Other Climax Relay manuals

Climax CL-DR-RL8X8A-N User manual

Climax

Climax CL-DR-RL8X8A-N User manual

Climax CL-AB-5AMR2 User manual

Climax

Climax CL-AB-5AMR2 User manual

Climax CL-DR-RL16X8A User manual

Climax

Climax CL-DR-RL16X8A User manual

Climax CL-PK-CPMR2) User manual

Climax

Climax CL-PK-CPMR2) User manual

Popular Relay manuals by other brands

Seg MRM3 manual

Seg

Seg MRM3 manual

Eaton easyE4 series Application note

Eaton

Eaton easyE4 series Application note

Littelfuse SE-330AU manual

Littelfuse

Littelfuse SE-330AU manual

Siemens SIRIUS 3RT1966-4D Original operating instructions

Siemens

Siemens SIRIUS 3RT1966-4D Original operating instructions

Allen-Bradley E300 user manual

Allen-Bradley

Allen-Bradley E300 user manual

Weidmüller TFIS 12-240VUC 1CO M7C Assembly and installation instruction

Weidmüller

Weidmüller TFIS 12-240VUC 1CO M7C Assembly and installation instruction

ABB CRN-1 Instruction leaflet

ABB

ABB CRN-1 Instruction leaflet

GE D30 series instruction manual

GE

GE D30 series instruction manual

GST DI-9302E manual

GST

GST DI-9302E manual

DEEsys DFR-021D manual

DEEsys

DEEsys DFR-021D manual

Pilz PNOZ e6vp operating instructions

Pilz

Pilz PNOZ e6vp operating instructions

ZIEHL TR 800 Web operating manual

ZIEHL

ZIEHL TR 800 Web operating manual

Bailey Infi 90 6642016 2 Series Instruction

Bailey

Bailey Infi 90 6642016 2 Series Instruction

Advantech PCIE-1760 user manual

Advantech

Advantech PCIE-1760 user manual

MSD 7564 installation instructions

MSD

MSD 7564 installation instructions

Dossena DER3BDUAL quick start guide

Dossena

Dossena DER3BDUAL quick start guide

Ice NPM800R user guide

Ice

Ice NPM800R user guide

VAMP VAMP 150 Operation and configuration instructions

VAMP

VAMP VAMP 150 Operation and configuration instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.