2 Channel Micro Relay (CL-PK-MR2)
Product Specification
Input Voltage
18V-24V DC (24V DC is recommended)
Input Current
45 mA -60 mA
Load Type
2 x4A Relay (Approx. 800 watt per channel–for resistive load)
I/O Connections
C-BUS
4 x Rising-cage 5mm screw terminals
Output
2 channel x Rising-cage 5mm screw terminals
Input
2 channel control input
Junction Box
Climax 2 Channel Micro Relay is designed basically to be
installed in a junction box behind a two channel contact Keypad.
The product size must be considered when applying it in
junction boxes.
Product Size: 50L X 44W X 25.7H (mm)
Screw Mounting
Screw the 2 Channel Micro Relay to any surface through 2 side
screw holes.
For screw mounting following part number must be used:
CL-PK-MR2-S
Use following instruction to connect module on C-Bus with Cat6 cable:
Color
Color Name
Pin
C-Bus
Orange/White
1
A(DATA+)
Orange
2
B(DATA-)
Green/White
3
TXD*
Blue
4
RXD*
Blue/White
5
GND
Green
6
GND
Brown/White
7
VCC
Brown
8
VCC
* TXD & RXD will be used only in direct mode application of module.
Change Device Address
The device address can be set from 0 to 31 by mean of a dip switch called
“address selector switch”. Before changing address the main power must be
disconnected. The address must be defined in binary. For instance for setting
address to “21” the address selector switch must be as bellow:
Never set the address to 0 and 1 as 0 is not valid in C-Bus protocol and 1 is
always dedicated for RS-232 GatewayPro module. Check all C-Bus modules
address to avoid repetitive address allocation.
Channel Toggling
Each channel can be toggled by connecting/disconnecting COM & corresponding
input on control pins.
Module LED’s
Upon connecting the main power, the green Power LED will start flashing.
The green Status LED flashes any time a valid data packet received to the micro relay.
In case of receiving invalid data packet in C-Bus connections, the Status LED will turn
on for 5 seconds.
At the time of connecting modules to each other Status LEDs might be turned on for 5
seconds while it must not be considered as an error.
Before wiring the device, always unplug the main power.
Before adding a new module on the C-Bus, ensure the previous module has a valid address
and is working properly.
In case of using capacitive or inductive loads, permissible current is less than normal mode
(resistive load) depending on load condition.
Follow the diagram below in order to apply right input/output and connect modules to
each other.

Other Climax Relay manuals

Climax CL-PK-CPMR2) User manual

Climax

Climax CL-PK-CPMR2) User manual

Climax CL-DR-RL8X8A-N User manual

Climax

Climax CL-DR-RL8X8A-N User manual

Climax CL-DR-RL16X8A User manual

Climax

Climax CL-DR-RL16X8A User manual

Climax CL-AB-5AMR2 User manual

Climax

Climax CL-AB-5AMR2 User manual

Popular Relay manuals by other brands

Savant CLI-REL1AUX1 Quick reference guide

Savant

Savant CLI-REL1AUX1 Quick reference guide

GE P4A Technical manual

GE

GE P4A Technical manual

Novatek-electro RNPP-302 operating manual

Novatek-electro

Novatek-electro RNPP-302 operating manual

Siemens SIRIUS 3RT2.1 Series operating instructions

Siemens

Siemens SIRIUS 3RT2.1 Series operating instructions

Woodward MFR 300 K55 Option manual

Woodward

Woodward MFR 300 K55 Option manual

resideo Protectorelay installation instructions

resideo

resideo Protectorelay installation instructions

macromatic Time Ranger TR-681 Series installation instructions

macromatic

macromatic Time Ranger TR-681 Series installation instructions

TE Connectivity PLL/D-100/120 Installation and operating instructions

TE Connectivity

TE Connectivity PLL/D-100/120 Installation and operating instructions

GE AKR-4-30 Maintenance manual supplement

GE

GE AKR-4-30 Maintenance manual supplement

System Sensor R-10T Installation and maintenance instructions

System Sensor

System Sensor R-10T Installation and maintenance instructions

Tyco Electronics 262-300 Installation and operating manual

Tyco Electronics

Tyco Electronics 262-300 Installation and operating manual

Westinghouse CO instructions

Westinghouse

Westinghouse CO instructions

BEA LE-21 user guide

BEA

BEA LE-21 user guide

Eaton Cooper Power Systems RLY-800 Instructional Leaflet

Eaton

Eaton Cooper Power Systems RLY-800 Instructional Leaflet

Siemens siprotec SJ62 user manual

Siemens

Siemens siprotec SJ62 user manual

Pilz PNOZ e4vp operating instructions

Pilz

Pilz PNOZ e4vp operating instructions

Saftronics PC10 manual

Saftronics

Saftronics PC10 manual

GMI D1044S quick start guide

GMI

GMI D1044S quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.